ELECTROSLAG STRIP OVERLAY OF PIPE, FITTINGS, AND PRESSURE VESSELS

  • Dan, Capitanescu
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.355-360
    • /
    • 2002
  • ElectroSlag Strip Overlaying (ESSO) process has been around since 1970. ESSO process had limited acceptance due to a few problems associated with the use of this process in its very early stage. Limited knowledge and, most significantly, poor quality of the equipment and welding flux gave the ESSO process a bad name. However, this process is well accepted today and used in North America, Europe and Japan. The ESSO process provides low dilution overlays at high deposition rates, excellent and consistent deposit chemistry with excellent surface quality, and virtually no defects. Capitan has taken this process one step further through extensive research and development of the process itself as well as the equipment. The improvement brought to the process warranted the issuance in May 2000 of an US patent. This study demonstrates the feasibility of this process with immediate positive production results. The main achievements of this work are as follows: $\textbullet$ Development of six various strip-flux combinations on three different base materials: carbon steel, $\frac{1}{4}$ Cr/.5 Mo and 2 $\frac{1}{4}$ Cr/l Mo, fully tested with: penetrant, ultrasound, bends, hardness, overlay chemistry, corrosion and hydrogen disbonding. $\textbullet$ 12" dia. 90 hot formed elbows from straight pipe electroslag overlayed with "1 layer" and "2 layer" Alloy 625 $\textbullet$ a very unique development of miniaturized overlaying equipment able to perform overlay in pipe with diameters as low as 10" (254 mm). This development has large applications in the field of offshore, petrochemical, refining, pulp and paper and power generation industries. The aftermath of this development was its immediate acceptance by major end users with the completion of four projects of overlayed pipe in the USA and Far East Asia.

  • PDF

Ultrasonographic evaluation of rotator cuff leison

  • Sugimoto Katsumasa;Matsui Nobuo
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 1995.03a
    • /
    • pp.46-46
    • /
    • 1995
  • We investigated the reliablity of the ultrasonography for diagnosis of rotatar cuff taers. We prepared histological sections of forty shoulder joints In match the ultrasound planes, and conducted a comparative study of tke two sets of images. hi cases of rotator cuff tear, hyperechogenic and cartilaginfication of the tear site were detected as hyperechogenic foci. On the countrary, the regions in which tendon fibers were decreased or absent showed sonolucent areas. We caluculated the echo level of rotator cuff objectively. The area of abnormal echo level and the other regions located in the same depth of the rotator cuff were defined by ultrasonic equipment. The mein difference in these two echo levels was calculated. The mean difference in patients with rotator cuff tears was larger than that in normal cases. These results indicate that ultrasonography is a useful procedure in many patients with rotator cuff lesions.

  • PDF

Analysis of Malignant Tumor Using Texture Characteristics in Breast Ultrasonography (유방 초음파 영상에서 질감 특성을 이용한 악성종양 분석)

  • Cho, Jin-Young;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.2
    • /
    • pp.70-77
    • /
    • 2019
  • Breast ultrasound readings are very important to diagnose early breast cancer. In Ultrasonic inspection, it shows a significant difference in image quality depending on the ultrasonic equipment, and there is a large difference in diagnosis depending on the experience and skill of the inspector. Therefore, objective criteria are needed for accurate diagnosis and treatment. In this study, we analyzed texture characteristics by applying GLCM (Gray Level Co-occurrence Matrix) algorithm and extracted characteristic parameters and diagnosed breast cancer using neural network classifier. Breast ultrasound images were classified into normal, benign and malignant tumors and six texture parameters were extracted. Fourteen cases of normal, malignant and benign tumor diagnosed by mammography were studied by using the extracted six parameters and learning by multi - layer perceptron neural network back propagation learning method. As a result of classification using 51 normal images, 62 benign tumor images, and 74 malignant tumor images of the learned model, the classification rate was 95.2%.

Application of Ultrasonic Energy to Fast Consolidation of Soft Clays (연약지만 압밀 촉진을 위한 초음파 에너지의 활용)

  • Park, Ji-Ho;Hwang, Jung-Ha;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.1039-1042
    • /
    • 2008
  • Dredged fills have been widely used to secure a land for the engineering activities. Before the useful application of the area, the soils should be consolidated to acquire the aquate shear strength. Several research projects have attempted to develop a method fur accelerating the consolidation of soft clay. Our study examined the effect of ultrasonic energy on the consolidation of soft clay, Tests were conducted using specially designed and fabricated equipment that was capable of directly applying ultrasonic energy to soil samples during consolidation tests. The specimens were prepared from slurry using a centrifuge facility, and tests were conducted at various levels of ultrasonic power and treatment time. The study showed that ultrasonic energy had a considerable effect on consolidation time, suggesting that ultrasound can be used to reduce the consolidation time of soft clay.

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

A Study on the Correlations between Total Prostate Volume and Prostate Transition Zone Volume Assessed Using Blood and Ultrasound Tests: in the Healthy Korean Men in Thirties (혈액, 초음파 검사 결과를 이용한 전립선이행대용적의 상관관계 연구: 기초질환이 없는 30대를 대상으로)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.407-412
    • /
    • 2017
  • This study investigates the correlations between the total prostate volume (TPV), using the prostate specific antigen (PSA) and prostate specific antigen density (PSAD) as the blood test results and transrectal ultrasound (TRUS), and the prostate transition zone volume (PTZV), as well as variables such as age; the findings can be used as clinical indicators. A retrospective analysis was conducted on 68 healthy men in their 30s who underwent TRUS and PSA and PSAD blood tests from June 2007 to April 2016, with no history of treatment in their prostate. Siemens Acuson sequoia 512 and the probe Siemens EC-10C5 Endocavitary were used as the ultrasound equipment. For statistical analysis, SPSS 18.0 was used to calculate the standard deviation and mean of each variable; Pearson's correlation analysis was also performed. The descriptive statistics of the variables were $24.27{\pm}6.60$ for TPV, $6.99{\pm}6.60$ for PTZV, $2.12{\pm}2.76$ for PSA, and $0.281{\pm}0.1$ for PSAD. The coefficients of correlations between PTZV and variables were 0.831 for PSAD, 0.707 for TPV, 0.398 for age, and 0.118 for PSA. While PSA and age were positively correlated, PSAD and TPV were highly correlated. Therefore, PTZV of men in their 30s without underlying diseases can be predicted using PSAD and TPV.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.

Basic study on proliferation control of cancer cells using combined ultrasound and LED therapeutic module (초음파와 LED를 이용한 일체형암세포 증식억제 모듈의 기초연구)

  • Cho, Kyung-rae;Choe, Se-woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1107-1113
    • /
    • 2018
  • Ultrasonography and photodynamic therapy have been proposed as useful tools as a treatment for inducing necrosis of cells using reactive oxygen species. Apoptosis is an internal mechanism necessary for cells regardless of damage. Ultrasound has the effect of inducing the apoptosis of these cells, and the frequency of 1 MHz is the most applicable area for medical use. The laser which is generally used in photodynamic therapy has a heat reaction and the treatment is limited. However, as a small light emitting diode is developed, it shows possibility to minimize the equipment and reduce heat reaction. On the other hand, there are relatively few researches on direct effects of light compared with studies using photosensitizers, and the area is also limited. Therefore, in this paper, we have developed a cancer cell proliferation control module using ultrasonic and light emitting diodes, which have relatively few side effects, and quantitatively analyze the effect of the module to propose an optimal suppression technique.

The Study on the Perceptions of Radiological Technologist in Medical Imaging Equipment Used by the Oriental Doctor (한의사의 의료영상장비 사용에 대한 방사선사의 인식도)

  • Choi, Jae-Ho;Kang, Gi-Bong;Kim, Sang-Hyun;Kim, Tae-Hee;Kim, Gyoo-Hyung;Lee, Mi-Hwa;Ahn, Jung-Seong;Hong, Seong-Wan;Lee, Jae-Seok;Kwon, Ick-Su;Park, Jae-Yoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.109-120
    • /
    • 2017
  • In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20~30s, neutral in the 40~50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.

The Effects of Transverse Abdominis Ratio and Balance Ability during Bridge Exercises on Different Support Surface (지지면 변화에 따른 교각운동이 복횡근 두께와 균형능력에 미치는 영향에 관한 연구)

  • Ann, Jun-il;Kim, Yoon-hwan;Park, Jong-hang;Ann, Mi-rae;Jung, Yeon-woo;Kim, Tae-won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effect of transverse abdominis ratio and balance ability during bridge exercises on different support surface. Methods: The subjects were 20 students at G University. Ultrasound equipment was used to measure the transverse abdominisratio and the computerized balance measurement equipment was used to measure the balance ability before and after bridge exercises on different support surface. Results: Transverse abdominis ratio change between the groups was a significant difference only in the unstable support surface training group (p<.05). Normal standing eye close balance ability change between the groups was significantly different only in the unstable support surface training group (p<.05). The changes in the transverse abdominis ratio after 7 days of exercise and 14 days after exercise were significantly different between the groups (p<.05). Normal standing eye close balance ability showed a significant difference at 7 days after exercise and 14 days after exercise (p<.05). Conclusions: It is more effective to balance ability and ratio of the transverse abdominis when bridge exercises on an unstable support surface than to perform bridge exercises on a stable support surface. Therefore, we propose an effective program for patients with instability of the lumbar in clinical practice. bridge exercises on different support surface.

  • PDF