• 제목/요약/키워드: Ultrasound equipment

검색결과 105건 처리시간 0.023초

초음파 적외선열화상 기법을 적용한 모터 코어의 신뢰성 평가 (Reliability Evaluation of a Motor Core Applied Ultrasound Infrared Thermography Technique)

  • 정윤수;노치성;이경일;김재열
    • 한국기계가공학회지
    • /
    • 제15권4호
    • /
    • pp.60-66
    • /
    • 2016
  • This study used an ultrasound infrared thermography technique to detect issues in the motor core of typical power equipment. The current defect inspection method of the motor core is often incomplete (due to the limits of visual inspection) and thus the reliability of the motor core is reduced. Therefore, in this study, experiments were carried out to increase the reliability of the test by using an ultrasonic infrared thermal non-destructive inspection method to image the motor core. The ambient temperature of the experimental system was maintained at $25^{\circ}C$. Experiments were carried out to examine a damaged motor core and a defect-free motor core. Experimental results confirm the technique clearly detected defects in the motor core, thereby confirming the possibility of using this technique in the field.

압밀촉진을 위한 초음파의 활용 (Fast Consolidation of Soft Clay due to Ultrasonic Energy)

  • Kim, Young-Uk;Song, Young-Karb;Kim, Boyung-Il
    • 한국지반공학회논문집
    • /
    • 제20권2호
    • /
    • pp.67-73
    • /
    • 2004
  • 준설매립 및 연약지반 처리에 있어 압밀촉진 공법들에 대한 연구가 활발하다. 본 연구에서는 초음파를 사용하여 압밀촉진을 유발하고자 하였고 그 영향 정도를 실내실험을 통하여 조사하였다. 실내시험은 특별히 제작된 압밀시험기를 사용하였으며 압밀시험 중 초음파를 시료에 직접 가할수 있도록 고안되었다. 압밀시험 재료로는 원심력 시험기를 사용하여 원하는 조건에 맞는 동질의 시료를 제작하여 사용하였으며 초음파 강도, 처리 시간을 달리하여 시험을 실시하였다. 시험결과 초음파가 압밀에 미치는 영향은 큰 것으로 나타났으며 초음파 처리의 영향에 미치는 정도가 시험조건에 따라 다르게 나타났다. 본 연구의 결과를 이용하여 초음파에 의해 압밀촉진을 위한 공법개발의 가능성을 파악하였다.

종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구 (A Study on the Architectural Planning of the X-ray Unit in General Hospital)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제12권3호
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

Ultrasonography for long-term evaluation of hyaluronic acid filler in the face: A technical report of 180 days of follow-up

  • Rocha, Luiz Paulo Carvalho;Rocha, Tania de Carvalho;Rocha, Stephanie de Cassia Carvalho;Henrique, Patricia Valeria;Manzi, Flavio Ricardo;Silva, Micena Roberta Miranda Alves e
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.175-180
    • /
    • 2020
  • Purpose: In this study, we used ultrasonography to monitor the use of hyaluronic acid (HA) as a filler in the face for esthetic reasons. We monitored changes in the filler shape, distribution, and relationship with adjacent anatomical structures over a 180-day period. Materials and Methods: Two patients each received an ultrasound-guided injection of HA, with different products and application sites for each patient. In 1 patient, the injection was administered in the angle of the mandible, while in the other, it was administered in the zygomatic region. The injection sites were monitored via ultrasonography at 24 hours, 30 days, and 180 days, at which times the imaging characteristics of the filler were observed. All injections were performed by the same professional, as were the ultrasound exams, which were conducted using the same equipment. Results: In both cases, the HA fillers were visualized using ultrasound at all time points. Some differences were observed between the cases in the images and the distribution of the pockets of filler. In 1 case, the filler appeared as a dark hypoechoic region with well-defined contours, and the material was observed to have moved posteriorly by the 180-day mark. In the other case, the material appeared hyperechoic relative to the previous case and presented no noticeable changes in its anteroposterior distribution over time. Conclusion: Based on these 2 cases, ultrasonography can be a complementary tool used to monitor facial fillers over the long term, allowing for the dynamic observation of different fillers.

A Fat-Tissue Mimic Phantom for Therapeutic Ultrasound

  • Kim, Mi Seon;Kim, Ju Young;Jung, Hyun Du;Kim, Jae Young;Choi, Heung Ho
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권3호
    • /
    • pp.153-159
    • /
    • 2014
  • As the number of treatments in the therapeutic ultrasound field targeted at fat tissue increase, the performance of the equipment should be evaluated for safety using a fat phantom. In this study, a fat phantom was fabricated using olive oil and a tissue-mimicking material (TMM) phantom. To evaluate the acoustic properties of the TMM phantom according to the changes in the olive oil, the composition ratio of a liquid mixture of olive oil with a surfactant was adjusted from 5-20% in 5% steps. The acoustic properties of the phantom were evaluated using the sound velocity, attenuation coefficient, density, and acoustic impedance. The experimental results showed that the sound velocity decreased with increasing amount of olive oil but the other acoustic properties did not change. In addition, the phantom using an olive-oil mixture with a 15% composition ratio was most similar to the acoustic characteristics of fat tissue with a sound velocity of 1477.35 m/s, an attenuation coefficient of 0.514 dB/MHz-cm, a density of $1.07g/cm^3$, and an acoustic impedance of 1.575 MRayl. These experimental results are expected contribute to the accuracy of the results using a TMM phantom and will be useful for the therapeutic ultrasound field targeted at subcutaneous fat tissue.

의료용 초음파 실습 시 장치의 세균오염도 측정에 관한 융합적 연구 (A Convergence Study on the Measurement of Bacterial Pollution in Medical Ultrasonic Practice)

  • 김동흔;박상희;박규태;정원희;김소연;홍희진;손나라;남설희;한만석
    • 한국융합학회논문지
    • /
    • 제10권10호
    • /
    • pp.75-80
    • /
    • 2019
  • 학교에서 의료용 초음파 실습 시 초음파 장치의 Freeze 및 Print Button, 프로브의 Lens, 손잡이, Line 부분 그리고 복부 Phantom에서 가장 접촉이 많은 부위를 임의로 선정하여 프로브에 상제하고 있는 세균을 검출하여 병원균의 수를 알아보고자 한다. 실험 방법으로는 실험 대상 위치에 균채집용 멸균된 면봉으로 검사 대상 부위를 20번 문지른 후 Lysogeny broth(LB) agar에 도말을 실시한 후 배양기에 넣어 48시간 동안 배양하고 colony forming unit (CFU) 수를 평가하여 프로브 손잡이, 복부 Phantom의 세균 분포정도를 알아보았다. 그 결과 CFU 값은 Lens는 $3.0{\pm}0.87$, Print button는 $5.5{\pm}1.06$, Freeze button은 $8.0{\pm}4.95$, Phantom은 $20.0{\pm}2.78$, Line은 $23.5{\pm}2.50$, 그리고 Probe handle의 값은 $35.3{\pm}10.75$로 측정되었다. 본 연구에서는 의료용 초음파 실습 시 실습 시 장비의 감염관리에 대한 주의를 부각시키고, 나아가서 초음파 장치의 세균 감염률 감소에 확실하게 기여 할 수 있을 것으로 기대된다.

이미지 가이드 시스템 기반 초음파 검사 교육 기법 개발: 예비 연구 (A Study on the Development of Ultrasonography Guide using Motion Tracking System)

  • 정영진;김은혜;최혜린;이채정;김서현;최유진;홍동희
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1067-1073
    • /
    • 2023
  • 유방암은 현대 여성들에게 가장 많이 발생하는 3대 암 중 하나로, 발생률이 급격하게 증가하고 있다. 가족력이 높고, 15% 정도의 사망률이 있어 고위험군에 속하므로 조기 검진 후 꾸준한 관리가 필요하다. 암을 진단할 수 있는 여러 장비 중 초음파는 위험성이 적고, 실시간으로 진단할 수 있다는 장점이 있다. 그러나 초음파 검사는 검사자의 기술에 따라 결과가 크게 달라진다. 이를 보완하기 위해 모션트래킹 기술을 접목하고자 한다. 모션트래킹은 삼차원의 공간에서 대상의 움직임에 따라 위치를 특정하고 분석하는 기술이다. 그렇기에 실시간 제어가 가능하고, 복잡하고 빠른 움직임도 실시간으로 기록할 수 있는 장점이 있다. 이러한 장점을 활용한 초음파 검사용 이미지 가이드 시스템 제작을 목표로 하였다. 이를 위해서 초음파스캐너의 위치를 3차원적으로 추정할 수 있는 자체 제작 완드(wand)를 설계하였고, 제작된 완드를 기반으로 초음파 영상의 위치를 추정하는 벡터 연산 알고리즘을 개발하였다. 이후, 연속 촬영을 통하여 3차원 공간에서 프로브의 위치와 초음파 영상의 위치를 나타내는 것까지 완료하였다. 이러한 실험은 Optitrack 사의 Primex 41 카메라를 초당 120 frame (Hz)으로 영상을 획득하며, 성공적으로 초음파 영상의 3차원 위치를 추정할 수 있었다. 이 실험 과정을 통해 초음파 검사와 모션트래킹의 접목으로 가이드 제작의 가능성을 확인하였다. 차후 추가적인 연구를 통해 초음파 검사 가이드를 제작하여 검사자의 기술과 상관없이 질 좋은 영상을 획득할 수 있기를 바란다.

초음파 적외선 열화상을 이용한 접합부의 미세균열 검출 연구 (Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography)

  • 박희상;최만용;박정학;이승석;허용학;이보영;김재성
    • 비파괴검사학회지
    • /
    • 제32권2호
    • /
    • pp.162-169
    • /
    • 2012
  • 본 논문은 초음파 적외선 열화상과 위상잠금 방법을 이용하여 이종금속용접(STS304 and SA106 Gr. b)된 파이프의 응력부식균열 결함을 검출하였다. 초음파 가진장치는 출력 250 Watt, 주파수 20 kHz이었다. 실험 결과 이종금속용접부의 파이프 내부에 위치한 균열을 적외선 열화상을 이용하여 검출할 수 있었다. 실제 PT검사를 통하여 배관 내부의 균열이 하나가 아닌 일정한 범위 안에 하나 이상의 크랙이 존재하여 열화상 이미지 상에 넓은 범위의 hot spot 이미지를 만들어 냈음을 파악할 수 있었다. 또한 기존 기술로 검출이 용이하지 못한 마이크로 폭의 미세균열을 검출할 수 있었다. 또한, 초음파탐상기술은 $10\;{\mu}m$ 미세크랙의 폭을 갖은 균열을 쉽게 검출하지 못하였다. 그러나 초음파 적외선 열화상 기술은 결함 검출하였다.

신생아 고해상 뇌 초음파검사에서 대상고랑의 깊이와 재태기간과의 관계 (Relationship between the depth of cingulate sulcus on neonatal high resolution cranial ultrasound and gestational age)

  • 최영칠;최진영;이정화
    • Clinical and Experimental Pediatrics
    • /
    • 제52권10호
    • /
    • pp.1136-1139
    • /
    • 2009
  • 목 적:신생아, 특히 미숙아에서 재태기간의 정확한 측정은 환자의 상태와 질병을 이해하여 치료하고 예후를 예상하는데 필수적이다. 이에 저자들은 신생아 뇌 초음파 검사시 최소한의 시간과 기구의 추가 사용으로 간편하게 정확한 재태기간을 추정할 수 있는 방법을 연구하였다. 방 법:일반적인 뇌 초음파 검사를 시행한 후 5-12 Mhz의 고해상도 선형 탐촉자를 사용하여 대천문을 통하여 관상면의 영상을 얻었고 여기에서 대뇌반구의 깊이와 뇌량의 두께 및 대상고랑의 깊이를 측정하여 재태기간과의 상관관계을 구하였다. 결 과:대뇌반구의 깊이, 뇌량의 두께 및 대상고랑의 깊이 중 재태기간과 가장 상관관계가 높은 측정치는 대상고랑의 깊이로 Pearson 상관계수 0.878을 보였다(P=0.000). 또한 대상고랑의 깊이가 0.55 cm 이상인 경우 단 두 례를 제외하고 모두 재태기간이 37주 이상이었고 대상고랑의 깊이가 0.35 cm 미만인 경우는 모두 34주 미만이었다. 결 론:고해상도 뇌 초음파 검사를 통해 측정된 대상고랑의 깊이는 신생아의 정확한 재태기간 측정에 유용하게 이용될 수 있다. 그러나 보다 더 많은 수의 신생아를 대상으로 한 대규모 연구가 필요할 것으로 생각된다.

유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구 (A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography)

  • 전철민
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.751-759
    • /
    • 2023
  • 유방 초음파 검사는 지방형 유방에서 영상화가 어렵고 미세 석회화를 찾는 데 어려움이 있지만, 미세 석회화의 발견은 유방암 선별 검사에 매우 중요하다. 초음파의 컬러 도플러 허상 중 반짝 허상은 영상에서 주로 결석이나 석회화 같은 강한 반사체에 발생되며 이를 이용한 평가 방법이 임상적으로 사용 중이다. 본 연구는 유방 석회화 중 가장 많이 차지하는 인산칼슘을 이용한 유방 모의 팬텀을 제작하여 초음파 장비의 컬러 도플러 설정 변수인 펄스 반복 주파수, 앙상블, 퍼시스트, 월 필터, 평활화, 선밀도, 임계값에 대해 실험을 진행했고 이를 통해 유방 초음파 검사에서 반짝 허상의 대조도를 개선하는 조건과 임상에서 이를 최대한 활용하기 위한 방안을 연구하고자 하였다. 그 결과 펄스 반복 주파수가 3.6 kHz ~ 7.2 kHz 범위에서 반짝 허상이 발생하며 10.5 kHz 이상에서는 발생하지 않았다. 앙상블의 경우 낮은 조건에서는 모든 크기의 석회화에 반짝 허상이 발생하였고 임계값 설정에서는 80에서 100 조건에서만 반짝 허상이 조금 증가했으며 1 mm 크기의 석회화에서는 발생하지 않았다. 퍼시스트, 월 필터, 평활화, 선밀도 설정은 반짝 허상이 발생하긴 했으나 조건별로 증가하지는 않아 설정 변수에 큰 의미가 없었으며 반짝 허상에 가장 큰 영향을 미친 것은 펄스 반복 주파수, 앙상블, 임계값으로 나타났다. 본 연구는 검사자가 컬러 도플러 설정을 조절하여 반짝 허상을 효과적으로 증가시키는 최적의 조건을 선택하는 데 도움이 될 것으로 사료된다.