• Title/Summary/Keyword: Ultrasound Scan

Search Result 133, Processing Time 0.035 seconds

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom (자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가)

  • Lee, Hyun-Kyung;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.895-900
    • /
    • 2019
  • Ultrasound is known to be harmless to the human body and is widely used in obstetrics and gynecology to confirm the diagnosis and development status of fetus. Diagnosis Although long - term use of ultrasound may cause changes in body temperature, studies on the uterine temperature changes due to ultrasound have been lacking. The purpose of this study was to investigate the change of temperature according to ultrasonic scanning time using a self - produced uterine model phantom. Ultrasound equipment and a 4MHz convex probe were used to construct the uterine model phantom similar to the human uterus using acrylic and pig uterus, which are tissue equivalents. Three probe type thermometers were installed to measure the inside of the acrylic water tank, the uterus, and the atmospheric temperature. The temperature of the uterine phantom was ascertained by measuring the temperature of the subject for 6 hours, 361 times. In this study, the possibility of human body temperature elevation due to ultrasound could be confirmed and this study will be used as the basic data of ultrasonic heat absorption study.

Predictive Markers for Screening Renal Damage in Children with Urinary Tract infections and Vesicoureteral Reflux

  • Lee, Hyeonju;Choi, Jae Hong;Kang, Dong-Hyeok;Kim, Seunghyo;Kang, Ki-Soo;Han, Kyoung Hee
    • Childhood Kidney Diseases
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2020
  • Purpose: Urinary tract infections (UTIs) are the most common and serious bacterial infections in children. Therefore, early diagnosis of vesicoureteral reflux (VUR) for treatment planning and the identification of noninvasive markers that can predict renal injury are important in patients with UTIs. We analyzed the clinical features of pediatric UTIs commonly encountered by general practitioners and reinterpreted the blood tests and imaging findings to identify the important clinical predictive markers of VUR in order to selectively perform VCUG. Methods: This retrospective study was performed among 183 children diagnosed with a UTI or acute pyelonephritis. Results: The most significant predictor of high grade and bilateral VUR identified using area under the curve analyses was hydronephrosis on kidney ultrasound images with renal cortical defects on dimercaptosuccinic acid (DMSA) kidney scan simultaneously, followed by hydronephrosis only on kidney ultrasound. Conclusion: The presence of hydronephrosis on kidney ultrasound images or cortical defects or asymmetric kidneys on the DMSA kidney scans can be predictive markers of VUR, reducing the need for VCUG. Our study can thus help minimize the exposure to radiation among patients through selective VCUG.

An Echo Processor for Medical Ultrasound Imaging Using a GPU with Massively Parallel Processing Architecture (병렬 처리 구조의 GPU를 이용한 의료 초음파 영상용 에코 신호 처리기)

  • Seo, Sin-Hyeok;Sohn, Hak-Yeol;Song, Tai-Kyong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.871-872
    • /
    • 2008
  • The method and results of the software implementation of a echo processor for medical ultrasound imaging using a GPU (NVIDIA G80) is presented. The echo signal processing functions are modified in a SIMD manner suitable for the GPU's massively parallel processing architecture so that the GPU's 128 ALUs are utilized nearly 100%. The preliminary result for a frame of image composed of 128 scan lines, each having 10240 16-bit samples, shows that the echo processor can be inplemented at a high rate of 30 frames per second when implemented in C, which is close to the optimized assembly codes running on the TI's TMS320C6416 DSP.

  • PDF

Implementation of a backend system for real-time intravascular ultrasound imaging (실시간 혈관내초음파 영상을 위한 후단부 시스템 구현)

  • Park, Jun-Won;Moon, Ju-Young;Lee, Junsu;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.215-222
    • /
    • 2018
  • This paper reports the development and performance evaluation of a backend system for real-time IVUS (Intravascular Ultrasound) imaging. The developed backend system was designed to minimize the amount of logic and memory usage by means of efficient LUTs (Look-up Tables), and it was implemented in a single FPGA (Field Programmable Gate Array) without using external memory. This makes it possible to implement the backend system that is less expensive, smaller, and lighter. The accuracy of the backend system implemented was evaluated by comparing the output of the FPGA with the result computed using a MATLAB program implemented in the same way as the VHDL (VHSIC Hardware Description Language) code. Based on the result of ex-vivo experiment using rabbit artery, the developed backend system was found to be suitable for real-time intravascular ultrasound imaging.

A Recursive Restoration Scheme of B-Scan Ultrasonographic Images in Noisy Case (잡음을 고려한 회귀방법에 의한 초음파 진단기의 화상개선)

  • Kim, Sun-I.;Min, Byoung-G.;Ko, Myoung-S.
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.35-42
    • /
    • 1982
  • The objective of this phantom study is to develop a digital method for improving the lateral resolution of B-scan ultrasonographic images irs medical application of ultrasound. By utilizing a discrete state-space modeling approach and Kalman-Buch method for analysis of the transducer's beam profile and the measurement and sampling noise, a stable recursive restoration of the object image was obtained for improved lateral resolution. The point spread function (PSF) was measured for the reflective signals after scanning the small pins located along the depth of interest. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF

A Case of Ectopic Thyroid Cyst Accompanied by Acute Airway Obstruction (급성 상기도 폐색을 동반한 이소성 갑상선 기원의 낭종 1예)

  • Kang, Dae-Woon;Lee, Yoon Se;Lim, Yune Sung;Lee, Jin-Choon
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.50-52
    • /
    • 2011
  • Ectopic thyroid gland is a defined as thyroid tissue located in a site other than its usual pre-tracheal location. Ultrasound examination, CT scan, thyroid scan, and thyroid iodine uptake test are all valuable modalities for a differential diagnosis. Although most of cases are asymptomatic, treatment is indicated when there are symptoms related to progressive growth of mass. This article reports a ectopic thyroid cyst in the anterior neck that was similar to deep neck infection accompanied by acute airway obstruction.

  • PDF

Ultrasonic Characteristics of Degraded Compacted Graphite Iron from 873 to 1,273 K (873~1,273 K에서 열화된 강화흑연강(Compacted Graphite Iron, CGI)의 초음파특성)

  • Lee, Soo-Chul;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.72-78
    • /
    • 2013
  • Compacted graphite iron 340 was carried out the heat treatment from 873 to 1,273 K. Compacted graphite iron 340 was evaluated relationship between the sound velocity, the attenuation coefficient and the tensile strength. The obtained results are as following. The signal strength of C scan images were weak according to increasing of heat treatment temperature and time. The amplitude of A scan and B scan was also low. This can be cause that the graphite was grown into the type of vermicular, and the many of grain boundary with ultrasound scattering were increase. The sound velocity was depend upon the heat treatment temperature and time, the attenuation coefficient had nothing to do with the temperature and time. The higher the heat treatment temperature, the tensile strength and the sound velocity were decreased. However, the tensile strength was proportional to the sound velocity. The higher tensile strength, the faster the sound velocity.

Calculation and Estimation of Acoustical Length from Ultrasound Signal for Diffraction Tomography (초음파 신호로부터의 음장의 계산 및 평가)

  • Park, Jong-Ho;Park, Jong-Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.278-284
    • /
    • 1986
  • There are considerabel interests in the use of acoustical lengths for characterization of scattered data required in diffraction tomography. In this paper, we present two new methods, calculation of acoustical lengths by Hibert transform and estimate on of integrated values on the scan lines from calcualted vales. These techniques offer insight into the acquisition of projection data in diffraction tomography. The validity of the proposed methods has bee confirmed by computer simulation.

  • PDF

The Decision of Voiding Cystourethrography in Children with Urinary Tract Infection (소아 요로감염에서 배뇨성 방광 요도 조영술의 결정)

  • Kim, Dong-Woon;Choi, Eung-Sang;Lim, In-Seok
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.203-211
    • /
    • 2007
  • Purpose : We attempted to compare the independent factors such as age, sex, C-reactive protein(CRP), and white blood cell count(WBC) in children with radiologic studies and assess the necessity of performing voiding cystourethrography(VCUG). Method : 98 children who have been diagnosed their first time febrile urinary tract infection from Janurary 2002 to Januray 2005 were enrolled. In all patient, the duration of fever which occurred before and after treatment was recorded, and CRP, WBC, $^{99m}Tc$-2,3-dimercaptosuccinic acid($^{99m}Tc$-DMSA) renal scans, renal ultrasound and VCUG were analyzed. Results : Of the 98 children diagnosed with urinary tract infection(UTI), 52 were male and 46 were female. 18 had abnormalities in VCUG, 17 had abnormalities in kidney ultrasound, and 20 had partial defects or diffuse uptake decrease in $^{99m}Tc$-DMSA renal scans. There were no significant relationship between incidence of radiologic abnormalities and age. The risk of renal scar was significantly higher in children who had a longer febrile period before treatment than in those with shorter period. Both CRP and WBC were significantly elevated in children with the radiological abnormalities. A positive of $^{99m}Tc$-DMSA renal scans and renal ultrasound were highly associated with vesicoureteral reflux(VUR). Conclusion : If there are abnormalities in the kidney ultrasound and $^{99m}Tc$-DMSA renal scan of a child with initial UTI, a VCUG is recommended. Even in cases without abnormal findings in $^{99m}Tc$-DMSA renal scan and renal ultrasound, clinical data such as CRP and WBC should be assessed, and VCUG should be Performed for the undetected VUR.

  • PDF