• 제목/요약/키워드: Ultrasonic transmission time

검색결과 66건 처리시간 0.02초

고온에 노출된 링형 강관 구속 콘크리트의 폭렬 및 초음파투과시간 (Spalling and Ultrasonic Pulse Transmission Time of Ring-Type Restrained Concrete exposed to High Temperature)

  • 황의철;김규용;이상규;손민재;편수정;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.174-175
    • /
    • 2019
  • In this study, the spalling and ultrasonic pulse transmission time of concrete were investigated according to compressive strength during heating. As a result, the higher the compressive strength of the concrete, the more the explosion occurs, which affects the cross-sectional loss and the spalling fragment size. Also, ultrasonic pulse transmission time was found to be strongly influenced by the section loss of concrete.

  • PDF

촉진 열화 목재의 초음파 전달 시간 측정을 통한 탄성 계수의 평가 (Evaluation of Modulus of Elasticity of Wood Exposed to Accelerated Weathering Test by Measuring Ultrasonic Transmission Time)

  • 박천영;김광철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권3호
    • /
    • pp.275-281
    • /
    • 2014
  • 본 연구에서는 전통 목조 건축물의 주재료인 목재를 인공 촉진 열화 시킨 후 초음파 전달 속도 측정을 통하여 탄성계수를 측정하였다. 촉진 열화 시간은 0시간에서 500, 1000, 1500, 2000시간이며, 자외선 조사와 주기적인 인공 강우를 통해 열화를 진행시켰다. 초음파 전달 속도 측정을 통하여 동적 탄성 계수를 평가하고 이를 3점 휨 시험을 통하여 측정한 정적 탄성계수와 비교분석하였다. 초음파 전달 속도, 정적 탄성계수, 동적 탄성계수는 열화 시간이 증가함에 따라 동일한 경향을 나타내었는데, 열화 1000시간까지는 탄성계수가 감소하다가 1500시간 이후 다시 회복되는 경향을 보였다. 이러한 결과는 비파괴 검사법을 통하여 전통 목조 건축물의 구조 부재의 열화 평가는 물론 구조 안전성 평가의 기초 자료로 활용될 수 있음을 알려준다.

Application of the Through-Transmitted Ultrasonic Signal for the Identification of Two-Phase Flow Patterns in a Simulated High Temperature Vertical Channel

  • Chu In-Cheol;Song Chul-Hwa;Baek Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.12-23
    • /
    • 2004
  • In the present study a new measurement technique has been developed, which uses an ultrasonic transmission signal in order to identify the vertical two phase flow pattern. The ultrasonic measurement system developed in the present study not only provides the information required for the identification of vertical two phase flow patterns but also makes real time identification possible. Various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. have been accurately identified with the present ultrasonic measurement system under atmospheric condition. In addition, the present test apparatus can practically simulate the ultrasonic propagation characteristics under high temperature and high pressure systems. Therefore, it is expected that the present ultrasonic flow pattern identification technique could be applicable to the vertical two phase flow systems under high temperature and high pressure conditions.

레일용접부의 용접결함검출을 위한 투과주사시스템의 구축 (Construction of Through Transmission Scanning System for Weld Defects Detection of Rail Weld Zone)

  • 윤인식
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2005
  • This study proposes construction of through transmission for weld defects detection of rail weld zone from ultrasonic signals. For these purposes, the ultrasonic signals for defects(porosity and crack) of weld zone in rails are acquired in the type of time series data and echo strength. 6 lines in the distance amplitude characteristics curve(DACC) indicated damage evaluation standard of weld zone in rails. The acquired ultrasonic signals agree flirty well with the mesured results of reference block and sensitivity block(defect location beam propagation distance, echo strength, etc). The proposed construction of through transmission in this study can be used for weld defects detection of rail weld zone.

유도초음파의 반사법과 투과법 비교를 통한 록볼트 건전도 평가 (Rock bolt integrity evaluation using reflected and transmitted guided ultrasonic waves)

  • 이종섭;유정동;한신인;배명호;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.42-50
    • /
    • 2008
  • To evaluate rock bolt integrity, destructive test such as pull-out test has been commonly carried out. This method is known as time consuming, expensive, and inaccurate procedure. To improve destructive method, non-destructive techniques using transmitted guided ultrasonic waves were suggested. Note for the transmission method, the source for the generation of ultrasonic waves should be installed during the rock bolt construction. The purpose of this study is to investigate the reflection method using reflected guided ultrasonic waves to evaluate the integrity of the rock bolt grouted, and to compare the results evaluated by the reflection and transmission methods. The guided waves are generated by PZT element and received by AE sensor. The measured signals are analyzed by the wavelet transform. The results show that the energy velocities of guided ultrasonic waves increase with the defect ratio in both transmission and reflection method. The reflection method produces the lower velocity in all defect ratio. This research demonstrates that the reflection method may be suitable and easer method for the field tests.

  • PDF

저장기간에 따른 사과 과육의 기계적 특성 및 초음파 파라미터 (Mechanical Properties and Ultrasonic Parameters of the Apple Flesh while in Storage)

  • 김기복;김만수;정현모;이상대
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.239-244
    • /
    • 2003
  • The potential use of ultrasonic technique for firmness measurement of apples was evaluated. Mechanical properties(bioyield deformation, bioyield strength, rupture deformation, ultimate strength, and elastic modulus) and ultrasonic parameters (ultrasonic velocity, attenuation coefficient and the first peak frequency) of the apple flesh during the storage time were measured and analyzed. Ultrasonic parameters were determined from the measurement of ultrasonic wave transmission through the apple flesh specimen. Mechanical properties were obtained by universal testing machine. The bioyield strength, rupture strength, elastic modulus, ultrasonic velocity, and the first peak frequency of the apple flesh decreased with the storage time. The bioyield deformation, rupture deformation, and ultrasonic attenuation coefficient increased with the storage time. The correlation analysis between ultrasonic parameters and mechanical properties and the storage time was performed. The high correlations were found between the storage time and the ultrasonic parameters, and these relationships seem to be useful for determining the firmness of the apple flesh.

습식방식의 초음파 유량계 시스템 개발에 관한 연구 (A Study on the Wet Type Ultrasonic Flow-meter System Development)

  • 이응석;권오훈;노명환;이형석
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

초음파 속도법을 이용한 콘크리트 구조물의 균열깊이 측정 (Crack Depth Evaluation of Concrete Structures using Ultrasonic Pulse Velocity method)

  • 오병환;김광수;김세훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.659-662
    • /
    • 1999
  • Ultrasonic pulse velocity method is employed for evaluation of crack depth in concrete structures. Due to the heterogeneous nature of concrete and the indirect transmission arrangement for the transit time measurement through the surface-opening cracks in concrete structures, ultrasonic pulse velocity has so many variations as crack depths and transmission lengths vary. In this study, ultrasonic pulse velocity method is investigated to evaluate the surface-opening crack depth of concrete slabs, reinforced concrete slabs, reinforced concrete flexural members. the resent study gives a modified method for deminishing errors in transit time measurements and show limitations to the evaluation of crack depth in reinforced concrete structures.

  • PDF

목재 내 초음파 전달 경로 구명 (Investigation of Transmission Process for Ultrasonic Wave in Wood)

  • 이전제;김광모;배문성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제31권2호
    • /
    • pp.31-37
    • /
    • 2003
  • 목재의 결함을 탐지하는 비파괴 진단법 중에서 초음파를 이용한 비파괴 시험법은 그 경제성과 사용에서 큰 장점을 지니고 있어, 그 활용과 관련된 연구가 활발히 진행 중이다. 그러나 현재까지의 연구는 입목 또는 원목 등과 같이 비파괴 평가를 위한 측정이 비교적 적은 경우에 국한되어 있어, 목조 문화재 등을 비롯한 구조물의 부재와 같이 부재의 일부 면만을 측정할 수 있는 경우에 대한 연구가 미비한 실정이다. 따라서 본 연구에는 이러한 초음파 시험기의 측정방법의 제한을 극복하는 방법을 모색하고자 그 첫 번째 단계로 결함을 갖는 목재 내에서 초음파 전달 경로를 구명하고자 하였다. 다양한 전달 경로 모델을 가정하고 실제 실험과 비교를 통해 초음파 전달의 가장 적합한 모델을 제시하고자 한다. 실험 시편에 인위적인 결함을 만들어 실험한 결과 초음파가 직접 전달될 수 없는 부분의 경우 그 결함을 피해서 전달되고 전달 경로는 탐촉자의 반대 측면에서 일차반사를 통해 전달되는 것으로 판단되었다.

Time Reversal Beam Focusing of Ultrasonic Array Transducer on a Defect in a Two Layer Medium

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Bae, Sung-Min
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.242-247
    • /
    • 2009
  • The ability of time reversal techniques to focus ultrasonic beams on the source location is important in many aspects of ultrasonic nondestructive evaluation. In this paper, we investigate the time reversal beam focusing of ultrasonic array sensors on a defect in layered media. Numerical modeling is performed using the commercially available software which employs a time domain finite difference method. Two different time reversal approaches are considered - the through transmission and the pulse-echo. Linear array sensors composed of N elements of line sources are used for signal reception/excitation, time reversal, and reemission in time reversal processes associated with the scattering source of a side-drilled hole located in the second layer of two layer structure. The simulation results demonstrate the time reversal focusing even with multiple reflections from the interface of layered structure. We examine the focusing resolution that is related to the propagation distance, the size of array sensor and the wavelength.