• 제목/요약/키워드: Ultrasonic frequency

검색결과 907건 처리시간 0.025초

초음파 진동 절삭공구 혼(tool horn)의 설계에 관한 연구 (A Study on the Design of Ultrasonic Vibration Cutting Tool Horn)

  • 강종표
    • 한국정밀공학회지
    • /
    • 제8권3호
    • /
    • pp.55-63
    • /
    • 1991
  • Transforming small ultrasonic energy into large mechanical energy is the essential feature of ultrasonic vibration in various application fields. This energy amplification can be obtained by achieving resonance condition between booster or tool horn and transducer. When it has uniform section with small sectional area, one dimensional analysis provides good estimation of the natural frequency of the horn. But, for arbitrary shape of horn, one dimensional analysis can no longer be applied. At present, designing tool horn whose natural frequency is identical to that of transducer requires serveral stages of trial and error in actual manufacturing process. In this paper, frequency analysis program is developed to easily predict the natural frequency of ultrasonic vibration cutting tool with axisymmetry and 3- dimensional shape using finite element method.

  • PDF

저장기간에 따른 사과 과육의 기계적 특성 및 초음파 파라미터 (Mechanical Properties and Ultrasonic Parameters of the Apple Flesh while in Storage)

  • 김기복;김만수;정현모;이상대
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.239-244
    • /
    • 2003
  • The potential use of ultrasonic technique for firmness measurement of apples was evaluated. Mechanical properties(bioyield deformation, bioyield strength, rupture deformation, ultimate strength, and elastic modulus) and ultrasonic parameters (ultrasonic velocity, attenuation coefficient and the first peak frequency) of the apple flesh during the storage time were measured and analyzed. Ultrasonic parameters were determined from the measurement of ultrasonic wave transmission through the apple flesh specimen. Mechanical properties were obtained by universal testing machine. The bioyield strength, rupture strength, elastic modulus, ultrasonic velocity, and the first peak frequency of the apple flesh decreased with the storage time. The bioyield deformation, rupture deformation, and ultrasonic attenuation coefficient increased with the storage time. The correlation analysis between ultrasonic parameters and mechanical properties and the storage time was performed. The high correlations were found between the storage time and the ultrasonic parameters, and these relationships seem to be useful for determining the firmness of the apple flesh.

초음파 주파수 분석법에 의한 결함의 정량적 평가에 관한 연구 (Quantitative Evaluation of Flaw by Ultrasonic Spectroscopy)

  • 한응교;김성규;박준서;이범성;박익근
    • 대한기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.1004-1010
    • /
    • 1992
  • 본 연구에서는 초음파 펄스 파형을 주파수 영역에서 해석하는 초음파 주파수 분석법을 결함 모델에 적용하여 결함의 정량화의 가능성을 검토하고, 그 결과를 반도 체 패키지내에 존재하는 보이드 및 박리에 응용함으로써 초음파 주파수 분석법에 기초 한 결함의 정량화에 관하여 연구하였다.

광대역 초음파 변환기를 위한 전기 임피던스 정합 연구 (Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer)

  • 김건우;김기복;백광세
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 초음파탐상법을 이용하여 마이크로미터의 크기 작은 결함을 검출하기 위해서는 높은 공진주파수와 큰 분해능의 초음파 변환기가 필요하다. 초음파 변환기의 공진주파수와 분해능은 변환기에 사용된 압전소자의 두께, 후면재 및 탐상 시스템 간의 전기 임피던스 정합과 밀접한 관련이 있으며, 이 중 전기 임피던스 매칭은 초음파 변환기와 초음파탐상 시스템 사이의 서로 다른 입 출력단을 연결하는 과정에서, 두 연결단의 전기적 임피던스 차이에 의한 에너지 반사와 손실을 줄이는 중요한 역할을 한다. 임피던스 정합에서 흔히 많이 사용하는 방법은 LC-정합회로이다. 이러한 LC-정합을 통해 탐상 시스템과 초음파 변환기의 전기 임피던스를 $50{\Omega}$으로 맞추어 두 연결단 사이의 임피던스 차이를 보정해 줌으로서 초음파 변환기에서 발생되는 전기신호의 손실을 줄 수 있다. 본 연구에서는 15 MHz의 공진주파수를 가지는 광대역 수침형 초음파 탐촉자를 제작하고 광대역 특성을 갖는 초음파 변환기를 위한 LC 임피던스 정합법을 적용하였다.

Improved Attenuation Estimation of Ultrasonic Signals Using Frequency Compounding Method

  • Kim, Hyungsuk;Shim, Jaeyoon;Heo, Seo Weon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.430-437
    • /
    • 2018
  • Ultrasonic attenuation is an important parameter in Quantitative Ultrasound and many algorithms have been proposed to improve estimation accuracy and repeatability for multiple independent estimates. In this work, we propose an improved algorithm for estimating ultrasonic attenuation utilizing the optimal frequency compounding technique based on stochastic noise model. We formulate mathematical compounding equations in the AWGN channel model and solve optimization problems to maximize the signal-to-noise ratio for multiple frequency components. Individual estimates are calculated by the reference phantom method which provides very stable results in uniformly attenuating regions. We also propose the guideline to select frequency ranges of reflected RF signals. Simulation results using numerical phantoms show that the proposed optimal frequency compounding method provides improved accuracy while minimizing estimation bias. The estimation variance is reduced by only 16% for the un-compounding case, whereas it is reduced by 68% for the uniformly compounding case. The frequency range corresponding to the half-power for reflected signals also provides robust and efficient estimation performance.

초음파 진동자를 이용한 알루미늄 와이어 용접에 관한 연구 (A Study on the Aluminum Wire Bondingby Using Ultrasonic Vibrator)

  • 김희수;이건복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.571-576
    • /
    • 1994
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. In order to improve the currently used wire bonding machine using ultrasonic energy, technical accumulation is needed steadily through development of exciting device of ultrasonic composed of piezoelectic vibrator and horn. This study investigates the design conditions affecting the dynamic characteristics through the theoretical and experimental analysis of piezoelectric vibrator and horn, The study conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. In theoretical model, the integrated modeling is conducted via a combination of dynamic identification of piezoelectric vibrator and theoretical analysis of horn. Hence comparison is made for theoretical and experimental results of the dynamic characteristics of the ultrasonic transducer composed of piezoelectric vibrator and horn. Form the results of this study we develop the design technique of ultrasonic transducer using dynamic characteristic analysis and propose the possibility of ultrasonic welding considering the optimal condition of the natural frequency and vibration mode of horn.

  • PDF

가청주파수 경계대역에서 저가의 통신채널을 제공하는 초음파 모뎀 구현 (Implementation of an Ultrasonic Modem Providing Low Cost Communication Channel in the Audio Frequency Boundary Band)

  • 전성배;이동원;정해
    • 한국정보통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1391-1396
    • /
    • 2010
  • 최근 출시되고 있는 PAN 용 통신부품으로 Bluetooth와 Zigbee가 선호되고 있으나 가전제품을 비롯하여 오디오기기, 휴대폰, PC 등에서 비교적 저속으로 단순한 메시지를 전달하는데 있어서 이러한 통신부품을 장착하기에는 다소 부담스럽고 제품이 복잡해진다. 본 논문에서는 제품에 이미 장착되어 있는 스피커와 마이크를 이용하여 가청한계 대역에서 초음파를 이용한 무선 통신 방법을 제안한다. 오디오 신호에 영향을 주지 않고 데이터 전송을 가능하게 하기 위하여 가청 한계 대역에서 ASK와 FSK 송수신 방식을 제시하고, 초음파 통신 모뎀을 설계 및 구현한다. 구현된 통신 모뎀은 배경 잡음이 있는 환경에서 실험을 통해 제안한 초음파 통신 모뎀의 성능을 검증한다.

초음파 신호분석을 이용한 접착접합 이음의 결함평가 (Evaluation of Flaws in Adhesively Bonded Joint using Ultrasonic Signal Analysis)

  • 황영택;오승규;한준영;장철섭;윤송남;이원;김환태
    • Journal of Welding and Joining
    • /
    • 제22권2호
    • /
    • pp.38-45
    • /
    • 2004
  • Ultrasonic signals transmitted through adhesively bonded plates were used to evaluate parameters related to attenuation and frequency in the adhesively bonded joint. The kinds of bonding materials with a different bonding thickness of constant pressure were used. And ultrasonic diagnosis was evaluated by p-wave sensor of 10MHz. FFT has been performed to determine bond-layer parameters such as effective thickness and frequency for adhesively bonded joint of A16061 plates in comparison with measured to theoretical ratios. When variable thickness exists, the ultrasonic spectrum was changed the frequency wave. The more materials thickness and the higher the frequency, the larger shift was observed. Measured ratios for cases of bond thickness and variety bonding materials are then used to determine bond parameters. The results show that the technique can be applied to the characterization of adhesively bonded joint.

저가의 통신채널 확보를 위한 가청주파수 한계대역에서의 초음파 모뎀 구현 (Implementation of an Ultrasonic Modem in the Audio Frequency Limit Band for Low Cost Communication Channel)

  • 전성배;이동원;정해
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.109-112
    • /
    • 2010
  • 최근 출시되고 있는 PAN 용 통신부품으로 Bluetooth와 Zigbee가 선호되고 있으나 가전제품을 비롯하여 오디오 기기, 휴대폰, PC 등에서 비교적 저속으로 단순한 메시지를 전달하는데 있어서 이러한 통신부품을 장착하기에는 다소 부담스럽고 제품이 복잡해진다. 본 논문에서는 제품에 이미 장착되어 있는 스피커와 마이크를 이용하여 가청 한계 대역에서 초음파를 이용한 무선 통신 방법을 제안한다. 오디오 신호에 영향을 주지 않고 데이터 전송을 가능하게 하기 위하여 가청 한계 대역에서 ASK와 FSK 송수신 방식을 제시하고, 초음파 통신 모뎀을 설계 및 구현한다. 구현된 통신 모뎀은 배경 잡음이 있는 환경에서 실험을 통해 제안한 초음파 통신 모뎀의 성능을 검증한다.

  • PDF

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.