• Title/Summary/Keyword: Ultra Sonic

Search Result 164, Processing Time 0.049 seconds

Implementation of a silicon sludge recycling system for solar cell using multiple centrifuge (다중 원심분리법을 이용한 태양전지용 실리콘 폐 슬러지 재생 시스템 구현)

  • Kim, Ho-Woon;Choi, Byung-Jin
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • This paper explained about the sludge recycling system which retrieved the silicon and abrasive from solar cell wafer slicing. The basic process of the recycling system was multiple centrifuge and secondary processes of ultra sonic agitation, addition of alcohol-water solution and heating sludge was added for raising separation efficiency. The recycling rate was about 96% and 94% for 2N, 4N silicon respectively. The SiC abrasive recycling rate was about 80%. To retrieve the high purity of 4N silicon, the heat process in vacuum furnace was added to remove remaining impurity components.

Proposal of a non-coherent Communication Protocol with Ultra Sonic which can Improve the Communication Speed (넌코히어런트 전송 방식에서 초음파를 이용한 디지털 통신속도 개선 프로토콜 제안)

  • Yoon, Byung-Woo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Propagation of electromagnetic wave in the water or underground is very difficult because of the conductivity of the propagation materials. In this case, we usually use acoustic signal as ultrasonic but, it is not easy to transfer long distance with coherent method because of time varying multipath, doppler effect, and attenuations. So, we use noncoherent method as FSK to communicate between long distances. But, as the propagation speed of acoustic sound is very slow, the BW of the channel is narrow. It is very hard to guaranty the enough speed of communication like digital image data. In this paper, we proposed a new data communication protocol which can transmit multi-bit digital data with every single ping, and improve the data communication speed in the water.

  • PDF

A Study on the Ground Following and Location Marking Method for Mine Detection System (지뢰 탐지를 위한 지면추종 및 탐지위치 표식에 관한 연구)

  • Lee, Myung-Chun;Shin, Ho-Cheol;Yoon, Jong-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1002-1008
    • /
    • 2011
  • The mine-detection system, which is one of the various mission equipments for Ground Vehicle System, detects mine under the ground. The mine detection sensors comprised of Metal Detection(MD) sensor and Ground Penetration Radar(GPR) are attached on the end of the multi-DOF manipulator. The manipulator moves the sensor to sweep mine areas keeping the pre-determined distance between the sensor and ground to enhance mine detection performance. The detection system can be operated automatically, semi-automatically and manually. When the detection system is operated automatically, the sensor should avoid collisions with unexpected obstacles which may exist on the ground. Two types of ultra-sonic sensors were developed for the mine detection sensor system to keep the appropriate gap between sensor and the ground to avoid the obstacles. Also, mine place marking device was developed.

Characteristics of downslope winds in the Liguria Region

  • Burlando, Massimiliano;Tizzi, Marco;Solari, Giovanni
    • Wind and Structures
    • /
    • v.24 no.6
    • /
    • pp.613-635
    • /
    • 2017
  • Strong downslope windstorms often occur in the Liguria Region. This part of North-Western Italy is characterised by an almost continuous mountain range along its West-East axis consisting of Maritime Alps and Apennines, which separate the Padan Plain to the North from the Mediterranean Sea to the South. Along this mountain range many valleys occur, frequently perpendicular to the mountain range axis, where strong gap flows sometimes develop from the top of the mountains ridge to the sea. In the framework of the European projects "Wind and Ports" and "Wind, Ports, and Sea", an anemometric monitoring network made up of 15 (ultra)sonic anemometric stations and 2 LiDARs has been realised in the three main commercial ports of Liguria. Thanks to this network two investigations are herein carried out. First, the wind climatology and the main statistical parameters of one Liguria valley have been studied through the analysis of the measurements taken along a period of 4 years by the anemometer placed at its southern exit. Then, the main characteristics of two strong gap flows that occurred in two distinct valley of Liguria are examined. Both these studies focus, on the one hand, on the climatological and meteorological characterisation of the downslope wind events and, on the other hand, on their most relevant quantities that can affect wind engineering problems.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Development of Ultra-High Temperature Ceramics (초고온 세라믹스의 발전 동향)

  • Lee, Sea Hoon;Park, Min-Sung;Zou, Yun
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.261-268
    • /
    • 2022
  • Ultra-high temperature ceramics (UHTC) such as ZrB2, ZrC, HfB2, HfC and TaC have been recently investigated for the application to hyper-sonic systems such as nose-cone, rocket nozzle and leading edge. In this paper, the recent research results about UHTC have been reviewed. Domestic and international research results about UHTC mainly during the last 5 years were briefly summarized. Also, the results of C3HARME project, which was one of the Horizon 2020 program in EU, to get over the problems of UHTC such as brittleness through the fabrication of ultra-high temperature ceramic matrix composites (UHTCMC) were briefly introduced.

Application of Air-Polisher (Air-Polisher의 응용법)

  • Kim, Min Jung
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.7 no.1
    • /
    • pp.72-78
    • /
    • 1998
  • Recently, esthetic dentistry has been developed because beauty is pursued by both dentists and patients. A scope of esthetic treatment has been expanded and the roles of hygienists in dental treatment have also become of importance. Generally, we make use of the ultra-sonic scaler to remove the stains attached to teeth surfaces, but when we utilize the rubber cup and pumice in prophylaxis, this increases the hypersensitivity, patient's anxiety, and chairtime. So, we substitute Air-polishing that increases patient's satisfaction and decreases chairtime for above method, Here, I would like to explain indications and contraindications, advantages and disadvantages, and usages of Air-polilshing briefly.

  • PDF

Phenolic Compounds Content and Antioxidant Activity of Rumex crispus Fractions

  • Lee, Kyoung-Min;Jeong, Gwi-Taek;Park, Don-Hee
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.264-267
    • /
    • 2005
  • The purpose of this study was to investigate the ultra sonic extraction method of phenolic compounds and antioxidant activity from Rumex crispus. Rumex crispus was fractionated with hexane, ethyl acetate, butanol and water. The amount of phenol compounds and antioxidant activity was presented higher content in ethyl acetate fraction then others.

  • PDF

Evaluation of Tunnel Lining Concrete Using Ultrasonic Pulse Velocity Method (초음파법을 이용한 무근콘크리트 터널라이닝의 품질평가)

  • 최홍식;이시우;신용석;오영석;오광진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.795-800
    • /
    • 2001
  • Two evaluation techniques of the tunnel lining concrete using ultra sonic velocity method are developed. Modified linear regression technique is proposed to enhance the corelation between the pulse velocity and the compressive strength of core specimens. And bivariate normal distribution is assumed to evaluate the quality of concrete as a terms of compressive strength. A simple corelation table between the pulse velocity and the compressive strength of core specimens are proposed.

  • PDF

The Study for Development on Earlier Evaluation Instrument of Strength of Concrete -Outline of Experiment and Investigation on Suitability of Instrument- (콘크리트 강도 조기 판정기의 개발에 관한 연구 (1) 실험 계획 및 실험기기의 적합성 검토)

  • 김화중;이도헌;윤상천;박정민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.435-440
    • /
    • 1994
  • It is considered to pressing problem that the develpment of the rapid and simple method and measuring instrument, can evaluate for quality of concrete at early period. Accordingly in this paper proposed to earlier evaluation method on quality of concrete using resistance method and ultra-sonic pulse velocity test. It was found to the possibility of development on test method and instrument through a series of fundmental investigation.

  • PDF