• Title/Summary/Keyword: UV light source

Search Result 172, Processing Time 0.023 seconds

Characteristics of porous 3C-SiC thins formed by anodization (양극 산화법으로 형성된 다공질 3C-SiC 막의 특성)

  • Kim, Kang-San;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.45-45
    • /
    • 2009
  • This paper describes the formation of porous 3C-SiC by anodization. 3C-SiC thin films were deposited on p-type Si(100) substrates by APCVD using HMDS (Hexamethyildisilane: $Si_2(CH_3)_6$). UV-LED(380 nm) was used as a light source. The surface morphology was observed by SEM and the pore size was increased with increase of current density. Pore diameter of 70 ~ 90 nm was achieved at 7.1 $mA/cm^2$ current density and 90 sec anodization time. FT-IR was conducted for chemical bonding of thin film and porous 3C-SiC. The Si-H bonding was observed in porous 3C-SiC around wavenumber 2100 $cm^{-1}$. PL shows the band gap enegry of thin film (2.5 eV) and porous 3C-SiC (2.7 eV).

  • PDF

Medical Treatment Machinery Based on LED Light Source (피부질환 치료용 LED 치료기)

  • Kim, J.T.;Bae, S.B.;Youn, D.H.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.5
    • /
    • pp.59-71
    • /
    • 2010
  • 피부질환 치료를 위한 광선요법은 태양광, 레이저, 형광등, UV 램프 등 다양한 광원을 이용하여 광이 피부 내에서 생화학적 반응을 촉진하는 원리를 이용하여 피부 조직의 선택적 재생 또는 파괴 등을 통해 손상된 피부를 치료하는 광 의료 기술이다. 최근 발전하고 있는 LED 광원 기술은 광선요법에서 시용되어온 광원을 대체할 수 있는 기술로 각광을 받고 있다. 이에 본 고에서는 광선요법과 관련된 기초 원리를 살펴보고, LED가 피부질환 치료용 광원으로 사용될 때 고려되어야 하는 임상적, 기술적 문제점과 다양한 피부질환 치료에 있어서 LED 광원의 역할에 대해 살펴 보았다. 아울러, 피부질환 치료용 LED 치료기 관련 국내외 연구 개발 동향과 기업들이 출시한 LED 치료기의 특성을 살펴보았다. LED 치료기 관련 표준화 동향과 국내외 지식재산권 현황을 살펴보았으며, 향후 LED 기반의 피부질환 치료기의 개발 방향을 모색하였다.

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Photocatalytic Decolorization of Rhodamine B using Immobilized TiO2 onto GF/C and Fluidized Bed Reactor (GF/C에 고정된 TiO2와 유동층 반응기를 이용한 Rhodamine B의 광촉매 탈색)

  • 박영식;안갑환
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1277-1284
    • /
    • 2003
  • The photocatalytic oxidation of Rhodamine B (RhB) was studied using immobilized TiO$_2$ and fluidized bed reactor. Immobilized TiO$_2$ onto GF/C was employed as the photocatalyst and a 30 W germicidal lamp was used as the light source and the reactor volume was 4.8 L. The effects of parameters such as the amounts of photocatalyst, initial concentration, initial pH, air flow rate and anion additives (NO$_3$$\^$-/, SO$_4$$\^$2-/, Cl$\^$-/, CO$_3$$\^$2-/) competing for reaction. The results showed that the optimum dosage of the immobilized TiO$_2$ was 40.0 g/L. Initial removal rate of immobilized TiO$_2$ was expressed Langmuir - Hinshelwood equation.

Visible Surface-Assisted Laser Desorption/Ionization Mass Spectrometry of Small Macromolecules Deposited on the Graphite Plate

  • Kim, Jung-Hwan;Paek, Kyung-Soo;Kang, Wee-Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.315-319
    • /
    • 2002
  • Visible surface-assisted desorption/ionization mass spectrometry (SALDI-MS) has been investigated for several small macromolecules deposited on the graphite plate using laser radiation at 532 nm where most of the macromolecules are transparent. The graphite surface functioned well as a photon absorbing material and an energy transfer mediator for visible light. The results show that visible SALDI is a much softer ionization technique than UV-MALDI and FAB-MS in our results with synthetic macromolecules, PPG, PPGMBE and cavitand molecules. For the SALDI of biomolecules, glycerol as a proton source was essential with the graphite plate. As in visible SALDI, the role division of the photon absorbing material and the cationization agent can provide a generality in mass spectrometric analysis of macromolecules compared with MALDI using the dual functional matrix.

Development and Operation Characteristics of XeCl Excimer Laser (방전여기 XeCl 엑시머레이저의 제작 및 동작특성)

  • Jin, Yun-Sik;Lee, Hong-Sik;Kim, Hee-Je;Rho, Young-Soo;Kim, Youn-Taeg
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.268-271
    • /
    • 1993
  • Discharge pumped high power excimer laser is a very useful light source of ultraviolet region. In this paper. the design and operation characteristics of UV pre-ionized discharge pumped XeCl laser are discussed. Maximum output power of 890mJ at the efficiency of 1.4% was achieved with 35kV charging voltage, 3.4atm of total pressure and 10pps of pulse repetition rate. Optimum HCl pressure is considered to be between 2.5 and 3.5torr.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.

Replication of label-free biosensor with nano grating structures (나노 그래이팅 구조를 갖는 비표지식 바이오센서 성형에 관한 연구)

  • Cho, E.H.;Kim, B.W.;Choi, S.W.;Kim, K.H.;Sung, G.Y.;Kang, S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.290-293
    • /
    • 2009
  • This paper presents the development of a disposable label-free biosensor for bio molecular interaction analysis. Label-free biosensors have advantages of high performance in sensitivity and short detection time. Among various label-free systems, we introduced biosensor with nano grating structures based on white light source and spectrometer. And to develop high efficiency label-free biosensor, we suggest replicating processes satisfying required specification. We also report a system set-up to evaluate the characteristics of phenomenon shown in this biosensor system.

  • PDF

The Attractant Effects of LED Lights on Aphidius colemani (콜레마니진디벌에 대한 LED 광원의 유인효과)

  • Eun Hye, Ham;Yun Bok, Nam;Hye Jeong, Jun;Young Gyun, Park;Un Taek, Lim;Young Su, Lee
    • Korean journal of applied entomology
    • /
    • v.61 no.4
    • /
    • pp.615-622
    • /
    • 2022
  • In this study, we sought to determine an appropriate LED light source that can be applied for the quality control of Aphidius colemani. Four LED light sources (385, 405, 450, and 660 nm) were evaluated in a Y-tube experiment (choice test) using a 5,000-k white LED as a control. The 385 nm LED light source was found to have attractant effect on A. colemani. In a no-choice test (Y-tube experiment) evaluating the remaining three LED light sources (385, 405, and 450 nm), the attractiveness of these light sources for A. colemani was high in the order 450 nm > 385 nm > 405 nm light, with no statistically significant differences between 450 nm and 385 nm. Given that 385 nm LED illumination may cause skin damage, we selected 450 nm LEDs for application in a device used for the quality control of A. colemani, which we subsequently demonstrated to have an attraction rate of 87.4%. We believe the findings of this study will make a valuable contribution to the quality control of natural enemies.

FBG Sensor Signal Processing System using SLD Tunable Light Source and Etalon Filter (SLD동조 광원과 에탈론 필터를 이용한 FBG 센서 신호처리 시스템)

  • Chung, Chul;Lee, Ho-Joon;Kim, Ki-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.39-44
    • /
    • 2004
  • Fiber Bragg grating sensors are fabricated by core index modulation using UV laser and phasemask. Bragg wavelength of the grating is changed by the external strain. In this paper, a signal processing system of fiber Bragg grating sensor has studied in the optical wavelength domain. The system is based on the sweep semiconductor light source that consists of SLD, F-P tunable filter and etalon filter. The hysteresis effects of PZT in the F-P tunable filter are compensated. The long term measurement stability is obtained by controlling the temperature of F-P tunable filter and the SLD. We compare the strain data from fiber Bragg grating sensor and that from strain gauge at concrete hume pipe. We also get very good results for the long gauge displacement using fiber Bragg grating sensor which are identical to the data with short gauge length ordinary displacement sensor.