• Title/Summary/Keyword: UPS inverter

Search Result 146, Processing Time 0.025 seconds

Design of Time Delay Compensator of Three-Level Inverter for Three-Phase UPS Systems (3상 UPS용 3레벨 인버터의 시지연 보상기 설계)

  • Lee, Jin-Woo;Lim, Seung-Beom;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.63-64
    • /
    • 2011
  • The inevitable calculation time delay of digital controller especially degrades the voltage control performance of three-phase UPS systems. This paper proposes time delay compensators based on the Smith-predictor for both voltage and current controllers of three-level NPC inverters. The PSIM-based simulation results show that the proposed controller with delay compensator gives improved voltage control performance with respect to time delay.

  • PDF

Output Filter and Controller designs for UPS Inverter with Single-Phase (단상 UPS 인버터의 출력필터와 제어기 설계)

  • Kim, Jae-Sig;Choi, Chang-Ho;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1064-1066
    • /
    • 2001
  • In this paper, the harmonic components generated by those two sources are analyzed separately based on the transfer function and shown as the closed form considering the switching frequency, speed of the control processor, gain of the controller, and the inductor and capacitor value of L-C filter. A design procedure is described with one flow chart and explained step by step.

  • PDF

Design and analysis of magnetic components for high power UPS system (대용량 무정전전원장치용 자성부품 설계 및 특성 분석)

  • Lee Dong Ju;Lee Eun Woong;Kim Yung Hun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.980-982
    • /
    • 2004
  • The aim of the paper is to introduce the high power UPS with unity input power factor and to analyze the its major magnetic components. Inductance and flux density of 3 phases boost reactor is obtained by finite element method and compared with its expermental result. Also, basic characteristic of inverter transformer is inverstigated.

  • PDF

Design of Narrowband Voltage Controller for Large Capacity Uninterruptible Power Supply with Low Switching Frequency (낮은 스위칭 주파수를 갖는 대용량 무정전전원장치를 위한 협대역 전압제어기 설계)

  • Yoon, Chun-gi;Cho, Younghoon;Lim, Seung-beom
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.149-150
    • /
    • 2015
  • This paper presents narrowband voltage controller for large capacity UPS system with low switching frequency. The proposed controller is repetitive controller applicable to low sampling. The controller reduces the control error for nonlinear load and improve efficiency. The proposed controller is verified through the experiment using 40kW UPS inverter.

  • PDF

Improvement of Naval Combat System UPS under Abnormal Transients (비정상 과도상태에서의 해군 전투체계 UPS 개선)

  • Kim, Sung-Who;Choi, Han-Go
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.97-103
    • /
    • 2018
  • This paper addresses an improved naval combat UPS(Uninterruptable Power Supply) system under abnormal transients. Previously, thermistor and varistor elements were used to cope with transient overvoltage and overcurrent, however the UPS was frequently unavailable because it was vulnerable to abnormal transient voltage generated during system operation. In order to overcome this problem and protect UPS system, this paper proposes an input power cut-off circuit that detects the initial input power and abnormal transient voltage generated during operation, improvement of power control sequence, and a method to prevent malfunction of an inverter and CPU. The UPS system implementing the proposed method was simulated by input power variable test using programmable AC/DC generator, and finally validated its reliability and stability through field tests by mounting on multifunctional console of naval combat system.

Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply (USP의 신뢰성 향상을 위한 독립제어 고속절환장치)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.278-286
    • /
    • 2008
  • This paper investigates the fault generation type and the cause of output interruptionsin bulky with $30^{\sim}500[KVA]$ double conversion UPS, and proposes the fault detection method to improve the reliability of power supply used in the critical load in industry. Identifies its existing way of detecting a quality of inverter output it to bypass when exceeds its expectation. Under a UPS managing system, when an inner (Power device, Controller, CPU) fault occurs it disrupts the power supply and these occurrences has been verified by the results of experiments and application results. To overcome these problems, the proposed method constructs independently a fault-detection, a bypass-control device and a triple power supply apart from the conventional UPS operation. Also the detection point is changed to the preceding of a circuit breaker, a reference of fault detection is modified to avoid any clash and the breaking equipment is attached to intercept a spread of accident. As a result of applications of these developed systems to 242 UPS which was installed purposefully to the communication power supply, the service errors has not occurred in the UPS for two years since 2006.

Control Characteristics of Current Controlled PWM Using Vector Control in VSI-IM Drive System (VSI-IM 구동 시스템에 벡터제어를 이용한 전류제어 PWM 방식의 제어특성)

  • Dong Hwa Chung
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.12
    • /
    • pp.38-50
    • /
    • 1991
  • A current-controlled scheme of pulse width modulation voltage source inverter (PWM VSI) has attracted considerable attention due to its fast response with current limit and especially suitable for potentially high performance applications such as AC motor drives and UPS systems. These features yield near-sinusoidal currents in the load with reduced current peaks, lower inverter switching frequency and reduce inverter and load stresses. A high performance current-controlled inverter must have a quick response in transient state and low harmonic current in steady state. This paper compares and shows the controlled-characteristics with hysteresis controller(HC), ramp comparison controller(RCC) and predictive controller(PC) of PWM inverter to control actual current of VSI-IM.

  • PDF

A novel resonant pulse control in resonant DC link inverter (공진형 직류 링크 인버터의 공진 펄스 제어기)

  • 유동욱;원충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.152-158
    • /
    • 1996
  • A novel resonant pulse control technique which generates high-quality sinusoidal output voltage from a resonant dc link inverter is presented for UPS applicatons. The proposed control technique limits resonant voltae overshoot without any passive or active clamp circuit, resulting in resonant pulses iwth uniform amplitude and high efficiency. The output voltage is controlled by the third order contorller iwth an inner loop of th efilter inductor current and the feedforward controller. Analysis and design of the proposed control technique are illustrated and verified on a 5kVA experimental unit.

  • PDF

Sag Voltage Compensator using Diode Rectifier and Series Inverter (다이오드 정류기와 인버터를 이용한 순간 전압 강하 보상기)

  • 이준기;박덕희;김희중;한병문;소용철
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.448-451
    • /
    • 1999
  • This paper describes controller development for a dynamic voltage compensator using a shunt diode converter and series inverter. The control system was designed using 1/4 period integrator and vector relationship between the supply voltage and load voltage. A simulation model and scaled hardware model were developed for analyzing performance of the controller and the whole system. Both results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system.

  • PDF

A Study on Synchronized AC Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic Effect

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Kim, Jong-Lae;Jang, Byong-Gon
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.547-553
    • /
    • 1998
  • In this paper, we composed of utility interactive pv generation system of voltage source inverter, and represented uninterrutible power supply (UPS) equipment maintaining constant voltage, using a pulse width modulation(PWM) voltage fed inverter, as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to dc side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

  • PDF