• 제목/요약/키워드: UHPC (ultra-high-performance-concrete)

검색결과 192건 처리시간 0.022초

반복충격을 받은 UHPC의 내충격성능 평가 (Evaluation of Impact resistance of UHPC Under Repeated Impact)

  • 정민승;김규용;이상규;황의철;김경태;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.161-162
    • /
    • 2018
  • In this study, it evaluate the impact resistance of UHPC by repeated impact. smooth steel fiber and polyvinyl alcohol fiber were reinforced in UHPC respectively. Overall, the impact resistance of the specimens reinforced with 0.4vol.% PVA fiber was high, and the crater diameter was small in specimens using 13mm fiber. When 19 mm steel fiber is used, the fracture depth is small due to the increase of macro crack resistance compared with other specimens. On the other hand, in the case of the fracture area, it is considered that the use of the fiber of 13 mm causes an increase in the stress dispersion effect to occur small.

  • PDF

고속 비상체 충격에 의한 시멘트 복합체의 파괴거동 평가 (Evaluation of Fracture Behaviours of Cementitious Composites by High-velocity Projectile Impact)

  • 민지영;조현우;이장화;김성욱;문재흠
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.55-62
    • /
    • 2015
  • 공공시설물의 대형화 및 도심지로의 인구 밀집화에 따라 충돌 또는 폭발과 같은 하중조건 하에서의 구조물 방호성능의 중요성이 대두되고 있다. 그러나 구조물의 방호설계 및 시공에 있어서 필수적이라 할 수 있는 구조 재료 또는 자재에 대한 방호성능 평가기준은 현재 정립되어 있지 않은 실정이다. 따라서 본 연구에서는 구조용 자재의 내충격 성능평가 기준 개발 연구의 일환으로 가스건을 사용한 발사체 충격 파괴시험을 콘크리트 시험체에서 수행함과 동시에, 다양한 접촉식 계측 센서의 적용 가능성을 확인하고자 하였다. 또한, 충격 파괴시험을 통해 일반 콘크리트 및 강섬유가 보강된 초고성능콘크리트의 파괴모드 및 방호성능에 대한 평가를 수행하였다. 실험 수행 결과, 접촉식 계측센서 중 LVDT 변위계의 적용 가능성을 확인하였으며, UHPC의 경우 혼입된 보강섬유의 효과로 인해 일반 콘크리트에 비해 우수한 방호성능을 보여주었다.

UHPC 외장패널을 활용한 비정형건축물 외장패널의 목업 시공사례에 대한 연구 - 부산 오페라 하우스 신축 공사 - (Study on Mock-up Construction Example of Free-Form Building Facade using External UHPC Panels - Focused on the Construction of Busan Opera House -)

  • 김태익;윤주용;최병걸;박용규;윤기원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.187-188
    • /
    • 2021
  • In the case of the Busan North Port, where the Busan Opera House is located, it is an environment exposed to various external deterioration factors such as frequent strong winds, seawater and salty winds, and an exterior material using UHPC (Ultra High Performance Concrete), a highly durable exterior material as a solution to this. Has been adopted. in this study, an economical production and construction direction was reviewed by applying UHPC to the exterior panels of atypical buildings that cannot cope with GFRC, metal, and glass, which are the main exterior finishing materials applied so far. When steel fibers are used, structural performance may be better than organic fibers, but due to environmental factors in Busan, corrosion due to exposure to steel fibers or problems with safety management after construction and completion may occur. Therefore, the site used the newly developed SACF fiber. Facade design of atypical buildings, which will increase in the future, is an important part, and the scope of use of UHPC panels is expected to increase in the future as design trends and demand for high durability increase.

  • PDF

Nondestructive detection of crack density in ultra-high performance concrete using multiple ultrasound measurements: Evidence of microstructural change

  • Seungo Baek;Bada Lee;Jeong Hoon Rhee;Yejin Kim;Hyoeun Kim;Seung Kwan Hong;Goangseup Zi;Gun Kim;Tae Sup Yun
    • Computers and Concrete
    • /
    • 제33권4호
    • /
    • pp.399-407
    • /
    • 2024
  • This study nondestructively examined the evolution of crack density in ultra-high performance concrete (UHPC) upon cyclic loading. Uniaxial compression was repeatedly applied to the cylindrical specimens at levels corresponding to 32% and 53% of the maximum load-bearing capacity, each at a steady strain rate. At each stage, both P-wave and S-wave velocities were measured in the absence of the applied load. In particular, the continuous monitoring of P-wave velocity from the first loading prior to the second loading allowed real-time observation of the strengthening effect during loading and the recovery effect afterwards. Increasing the number of cycles resulted in the reduction of both elastic wave velocities and Young's modulus, along with a slight rise in Poisson's ratio in both tested cases. The computed crack density showed a monotonically increasing trend with repeated loading, more significant at 53% than at 32% loading. Furthermore, the spatial distribution of the crack density along the height was achieved, validating the directional dependency of microcracking development. This study demonstrated the capability of the crack density to capture the evolution of microcracks in UHPC under cyclic loading condition, as an early-stage damage indicator.

실리카 퓸의 첨가량에 따른 UHPC의 강도와 내부조직에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect on Strength and Internal Structure for UHPC by Silics Fume Replacement Ratio)

  • 박정준;강수태;류금성;고경택;김성욱;이장화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.765-768
    • /
    • 2008
  • UHPC에서의 실리카 퓸은 강도와 유동성 증진에 있어 매우 중요한 요소라 할 수 있으며 그 사용량은 시멘트에 대해 25%이상(중량비)을 보편적으로 사용하고 있으나 실리카 퓸의 사용량에 따른 UHPC에 미치는 영향을 파악하는 노력들이 필요하다. 이에 본 연구에서는 실리카 흄의 사용량에 따른 유동성, 압축강도, 탄성계수, 휨강도의 역학적 특성과 SEM 및 MIP(Mercury Intrusion Porosimetry)를 통한 내부조직을 검토하였다. 검토결과, 적절한 실리카 퓸의 사용은 유동성과 강도를 증진시키는데 이는 포졸란 반응에 의한 수화물질의 증대와 필러역할에 의한 콘크리트 내부의 밀도가 효과적으로 증진되어 강도가 증가한 것을 MIP 실험을 통해 알 수 있었다. 또한 시멘트에 대해 중량비로 $10{\sim}25%$ 범위 내에서는 비슷한 역학적 특성을 나타내는 것으로 판단된다.

  • PDF

Test and simulation of circular steel tube confined concrete (STCC) columns made of plain UHPC

  • Le, Phong T.;Le, An H.;Binglin, Lai
    • Structural Engineering and Mechanics
    • /
    • 제75권6호
    • /
    • pp.643-657
    • /
    • 2020
  • This study presents experimental and numerical investigations on circular steel tube confined ultra high performance concrete (UHPC) columns under axial compression. The plain UHPC without fibers was designed to achieve a compressive strength ranged between 150 MPa and 200 MPa. Test results revealed that loading on only the UHPC core can generate a significant confinement effect for the UHPC core, thus leading to an increase in both strength and ductility of columns, and restricting the inherent brittleness of unconfined UHPC. All tested columns failed by shear plane failure of the UHPC core, this causes a softening stage in the axial load versus axial strain curves. In addition, an increase in the steel tube thickness or the confinement index was found to increase the strength and ductility enhancement and to reduce the magnitude of the loss of load capacity. Besides, steel tube with higher yield strength can improve the post-peak behavior. Based on the test results, the load contribution of the steel tube and the concrete core to the total load was examined. It was found that no significant confinement effect can be developed before the peak load, while the ductility of post-peak stage is mainly affected by the degree of the confinement effect. A finite element model (FEM) was also constructed in ABAQUS software to validate the test results. The effect of bond strength between the steel tube and the UHPC core was also investigated through the change of friction coefficient in FEM. Furthermore, the mechanism of circular steel tube confined UHPC columns was examined using the established FEM. Based on the results of FEM, the confining pressures along the height of each modeled column were shown. Furthermore, the interaction between the steel tube and the UHPC core was displayed through the slip length and shear stresses between two surfaces of two materials.

Design and behavior of 160 m-tall post-tensioned precast concrete-steel hybrid wind turbine tower

  • Wu, Xiangguo;Zhang, Xuesen;Zhang, Qingtan;Zhang, Dong;Yang, Xiaojing;Qiu, Faqiang;Park, Suhyun;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.407-421
    • /
    • 2022
  • Prefabricated hybrid wind turbine towers (WTTs) are promising due to height increase. This study proposes the use of ultra-high performance concrete (UHPC) to develop a new type of WTT without the need to use reinforcement. It is demonstrated that the UHPC WTT structure without reinforcing bars could achieve performance similar to that of reinforced concrete WTTs. To simplify the design of WTT, a design approach for the calculation of stresses at the horizontal joints of a WTT is proposed. The stress distribution near the region of the horizontal joint of the WTT structure under normal operating conditions and different load actions is studied using the proposed approach, which is validated by the finite element method. A further parametric study shows that the degree of prestressing and the bending moment both significantly affect the principal stress. The shear-to-torsion ratio also shows a significant influence on the principal tensile stress.

Effect of ages and season temperatures on bi-surface shear behavior of HESUHPC-NSC composite

  • Yang Zhang;Yanping Zhu;Pengfei Ma;Shuilong He;Xudong Shao
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.359-376
    • /
    • 2023
  • Ultra-high-performance concrete (UHPC) has become an attractive cast-in-place repairing material for existing engineering structures. The present study aims to investigate age-dependent high-early-strength UHPC (HESUHPC) material properties (i.e., compressive strength, elastic modulus, flexural strength, and tensile strength) as well as interfacial shear properties of HESUHPC-normal strength concrete (NSC) composites cured at different season temperatures (i.e., summer, autumn, and winter). The typical temperatures were kept for at least seven days in different seasons from weather forecasting to guarantee an approximately consistent curing and testing condition (i.e., temperature and relative humidity) for specimens at different ages. The HESUHPC material properties are tested through standardized testing methods, and the interfacial bond performance is tested through a bi-surface shear testing method. The test results quantify the positive development of HESUHPC material properties at the early age, and the increasing amplitude decreases from summer to winter. Three-day mechanical properties in winter (with the lowest curing temperature) still gain more than 60% of the 28-day mechanical properties, and the impact of season temperatures becomes small at the later age. The HESUHPC shrinkage mainly occurs at the early age, and the final shrinkage value is not significant. The HESUHPC-NSC interface exhibits sound shear performance, the interface in most specimens does not fail, and most interfacial shear strengths are higher than the NSC-NSC composite. The HESUHPC-NSC composites at the shear failure do not exhibit a large relative slip and present a significant brittleness at the failure. The typical failures are characterized by thin-layer NSC debonding near the interface, and NSC pure shear failure. Two load-slip development patterns, and two types of main crack location are identified for the HESUHPC-NSC composites tested in different ages and seasons. In addition, shear capacity of the HESUHPC-NSC composite develops rapidly at the early age, and the increasing amplitude decreases as the season temperature decreases. This study will promote the HESUHPC application in practical engineering as a cast-in-place repairing material subjected to different natural environments.

FRP 시트 및 강섬유 보강 콘크리트의 저속 충격에서의 휨 및 펀칭 파괴 거동 (Flexural and Punching Behaviors of Concrete Strengthening with FRP Sheets and Steel Fibers under Low-Velocity Impact Loading)

  • 민경환;신현오;류두열;윤영수
    • 콘크리트학회논문집
    • /
    • 제23권1호
    • /
    • pp.31-38
    • /
    • 2011
  • 이 연구에서는 FRP와 강섬유로 보강한 콘크리트 시편의 충격하중과 정적하중에서의 거동을 보기 위해 휨 실험과 펀칭 실험을 수행하였다. 1방향 휨 실험과 2방향 펀칭 실험에서 콘크리트 시편은 각각 $50{\times}100{\times}350$ mm와 $50{\times}350{\times}350$ mm의 크기로 제작하였다. 0.75% 혼입률의 강섬유 보강 콘크리트는 2방향 충격하중 및 정적하중에서 높은 저항 성능을 보였다. 일반 콘크리트와 강섬유 보강 콘크리트에서 FRP 보강은 높은 성능 증가를 보였다. 초고성능 콘크리트는 콘크리트 자체가 가지고 있는 높은 인장강도와 인성으로 인해, CFRP로 보강한 경우 강도와 에너지 소산 능력이 크게 증가하지 않았다.

72m 초고강도 콘크리트 프리스트레스트 박스 거더의 수치 해석 (Numerical Simulation of 72m-Long Ultra High Performance Concrete Pre-Stressed Box Girder)

  • 비엣 징 마이;한상묵
    • 한국전산구조공학회논문집
    • /
    • 제35권2호
    • /
    • pp.73-82
    • /
    • 2022
  • 이 논문은 72m 초고강도 콘크리트 섬유보강 콘크리트 프리스트레스트 박스거더의 비선형 거동을 해석하는 3차원 해석방법을 제시하였다. UHPC재료의 비선형 거동을 나타내기 위해 콘크리트 손상소성(CDP)모델을 채택하였다. 제시된 응력-변형률 관계 곡선에 근거한 수치해석 모델은 50m UHPC 프리스트레스트 박스 거더 휨실험결과로 검증하였다. 검증된 해석모델을 사용하여 72m UHPC 프리스트레스트 박스거더의 휨거동을 파악하는데 적용하였다. 각 하중단계에 따른 하중 변위관계, 응력상태 및 연결부분 상세를 해석하였다. 하중-변위관계 곡선과 설계하중 및 극한하중 비교 결과는 UHPC 박스거더 휨거동을 해석하는 적절한 수단으로써 비선형 유한요소법의 적용성을 입증하고 있다.