• Title/Summary/Keyword: Type C test

Search Result 1,934, Processing Time 0.031 seconds

Effect of Temperature and Salinity on Production of Resting Egg in Korean Rotifer, Brachionus plicatilis (L and S-type)

  • Park, Heum-Gi;Hur, Sun-Bum
    • Journal of Aquaculture
    • /
    • v.9 no.4
    • /
    • pp.321-327
    • /
    • 1996
  • Production of resting egg from the Korean rotifer, Brachiunus plicatilis (L and S-type) was investigated at different temperatures (L-type : 20, 24, $28^{\circ}C$, S-type : 28 32, $36^{\circ}C$) and salinities (10, 20,30 ppt). The rotifer was cultured in 25 ml test tube and fed on Nannochloris oculata. With regard to mixis rate, L-type rotifer showed higher rate at lower temperature, and the highest rate was observed at 20 ppt of salinity at each temperature of the experiment. However, for S-type rotifer, the optimum temperature and salinity were $28\~32^{\circ}C$ and 20 ppt, respectively. The highest number of resting egg was 173 eggs/ml in 16 days at $24^{\circ}C$, 10 ppt for L-type rotifer and 410 eggs/ml in 14 days at $28^{\circ}C$, 10 ppt for S-type rotifer. The maximum number of resting egg produced per 10,000 rotifers was 8,122 eggs at $20^{\circ}C$, 20 ppt for L-type rotifer and 8,700 eggs at $28^{\circ}C$, 20 ppt for S-type rotifer. The maximum number of resting egg produced $10^8$ cells of N. oculata was 50.7 eggs for L-type rotifer ($24^{\circ}C$, 20 ppt) and 79.6 eggs for S-type rotifer ($32^{\circ}C$, 10 ppt). The number of resting egg produced per day was $1\~11$ eggs/ml for L-type rotifers and $21\~35$ eggs/ml for S-type rotifer in 9 combination experiments. In this study, S-type rotifer is better than L-type rotifer in resting egg production, and the optimum temperature and salinity for resting egg production were $20^{\circ}C$, 20 ppt for L-type rotifer and $28^{\circ}C$, 20 ppt for S-type rotifer. This result shows the difference of Korean rotifer in the optimum condition for resting egg production from other rotifers reported earlier.

  • PDF

Measurement of Traceability Error for Calibration Service Center Using Type S Thermocouples (S형 열전대를 이용한 교정검사기관의 소급성 오차측정)

  • Gam, Kee-Sool;Kim, Yong-Gyoo;Kim, Sun-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.43-50
    • /
    • 1995
  • We measured the traceability error for nine high temperature calibration service centers including KRISS through the round-robin test. In this test the type S thermocouple, which used as a calibration standard thermometer commonly, was accommodated as a test thermocouple. Intercomparison data of three institutions were coincident with KRISS's data within ${\pm}0.5^{\circ}C$, which was the calibration uncertainty of the type S thermocouple, but the remaining six institution's data were deviated from the assigned uncertainty level. Deviation of the intercomparison data increased gradually according to the increase of the test temperature. and the maximum difference was so large as about $2.0^{\circ}C$ at the highest test temperature, gold point. In this study we found the traceability error of high temperature calibration service center for a high temperature standard was within $2.0^{\circ}C$.

  • PDF

A Comparison of Chromium and Copper-Containing Waterborne Wood Preservatives for Fixing and Leaching Characteristics (크롬-구리 화합물계(化合物系) 목재방부제(木材防腐劑)의 정착(定着) 및 용탈특성(溶脫特性) 비교(比較))

  • Ra, Jong-Bum;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.66-72
    • /
    • 1995
  • The rate of fixation of the components were evaluated in CCA-Type B and CCFZ-treated radiata pine sapwood by quantitative analysis of solution expressed from the treated wood. The leaching characteristics of radiata pine blocks treated with CCA-Type B and CCFZ were also evaluated by the AWPA standard leaching test. Both fixation and leaching charactersistics of CCA-Type B were compared with CCA-Type C treated wood samples. The rate of CCA-Type B fixation was a little faster than that of CCFZ. However, significant amounts of arsenic was unfixed in the CCA-Type B treated samples and consequently leached. These significant quantities of arsenic liberated from the CCA-Type B treated wood during service may pose some environmental concerns. Arsenic was no longer detectable from CCA-Type C treated samples when fixation was complete, even though the fixation of CCA-Type C was slower in some degree than CCA-Type B. In summary, it could be said that CCFZ was much safer preservative than CCA-Type B by the criterion based on the relative hazard assessed by absolute amount of unfixed element present in the treated wood. Also the decision that CCA preservative has to move from Type B to Type C should be made sooner or later for continuous use of CCA preservative in the future.

  • PDF

An experimental study on the reduction of autogenous shrinkage of high strength concrete with bar restricted specimen (철근구속을 받는 고강도 콘크리트의 자기수축저감에 관한 실험 연구)

  • 최진영;전철송;임병호;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.431-436
    • /
    • 2002
  • In this paper, to seek a solution of reducing autogenous shrinkage three types of bar restricted concrete specimens which have similar compressive strength were tested. The three type of concrete were plain concrete-P25 type, $10^{\circ}C$ fly-ash replaced concrete-F10 type, and $1^{\circ}C$ expansion admixture replaced concrete-SP1 type, and with the test result an experimental study was conducted to gain the tensile stress of concrete. From the result of P25, SP1, F10 tests, it was found that by the age of 14 the ratios of tensile stress to tensile strength of three specimens are $75^{\circ}C$, $47^{\circ}C$, $52^{\circ}C$ respectively. so we came to a conclusion that the SP1-type concrete has better capacity to reduce autogenous shrinkage than F10-type concrete at similar compressive strength condition.

  • PDF

Variation Analysis on the Quality of Blast Furnace Slag Type Ⅲ that affects Carbonation of Concrete (Type Ⅲ 고로슬래그 미분말의 품질이 콘크리트의 중성화에 미치는 영향에 관한 분산분석)

  • Min, Jeong-Wook;Park, Seung-Bum;Lee, Byoung-Jai;Yoon, Eui-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.605-608
    • /
    • 2008
  • We have studied statistically about quality difference of Blast furnace slag Type Ⅲ that affects carbonation of concrete. According to KS F 2563 blast furnace slag was classified 3 types. Type Ⅲ blast furnace slag(specific surface area is $4000cm^2/g$) from different providers with Type A, the B and the C. The statistical technique was applied to exclude error of engineering judgement. T test and F test were used among 3 groups to investigate statistical meaning. The effect which on the quality of blast furnace slag type Ⅲ that affects carbonation of concrete is significant.

  • PDF

A Study on the Classification of Domestic Fire Detector using Response Time Index (반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구)

  • Hong, Sung Ho;Kim, Dong Suck;Choi, Ki Ok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

Measurement of Real Deformation Behavior in C-type Lng Mock-up Tank using Strain Gage (스트레인 게이지를 이용한 C-type LNG Mock-up 탱크 내조 실 변형 거동 측정)

  • Jung, Won-Do;Kim, Tae-Wook;Kim, Jeong-Hyeon;Lee, Do-Young;Chun, Min-Sung;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • A C-type LNG mock-up tank was constructed to evaluate the durability of the tank and its structural safety. An experimental strain analysis system equipped with strain gages was designed to investigate the structural behavior of the inner tank at a high hydraulic pressure. In addition, the insulation used in the space between the inner tank and outer tank had a compressive strength and the inner tank thickness of the cylindrical shell and hemisphere was 4.0 mm, which was designed to be thinner than the existing rules. The strains on the inner tank were measured with increasing pressure, and these measurements were compared and analyzed at the strain gage attachment points.

Study on Heat Transfer Coefficient Test of Evaporator Tube in Shell and Tube Heat Exchanger by Shape (관 형태에 따른 Shell and Tube 열교환기의 열전달계수 관한 연구)

  • Kwon, Jae-Jeong;Park, Jae-Hong;Kim, In-Kwan;Kim, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1107-1112
    • /
    • 2006
  • The purpose of this study is a heat transfer coefficient test of evaporator tube in shell and tube heat exchanger by shapes, using R-404A. The experimental apparatus is designed to simulate the real heat transfer rate in one shell and tube heat exchanger. The test section is formed four type tubes that are Inner ridged tube, Corrugated tube, Turbo-C tube, Inner fin tube and shell type is formed by electrical heater. All tests were performed at a fixed refrigerant evaporator temperature at $1.5^{\circ}C,\;-3^{\circ}C$ and with mass fluxes of 29, 25 kg/hr. Heat transfer rate is calculated a enthalpy difference in test section. In experiment, heat transfer coefficient measured one by one and electrical heaters are supplemented by evaporator.

  • PDF

A Study on Self Management, Hemoglobin A1c (HbA1c), and Perceived Health Status for the Type II Diabetes Patients (제2형 당뇨병 환자의 자가관리, 당화혈색소 및 주관적 건강상태)

  • Park, Ju-Young
    • Journal of Korean Biological Nursing Science
    • /
    • v.12 no.2
    • /
    • pp.106-113
    • /
    • 2010
  • Purpose: This study is conducted to examine the relationship among self management, HbA1c, and perceived health status of type II diabetes patients in community health department. Methods: Data were collected from 93 type II diabetes patients who are registered at five community health center using comprehensive survey, modified self care behavior, blood glucose and HbA1c were assessed by nurses. The data was analyzed by the SPSS (14.0) computer program, and it included descriptive statistics, t-test, ANOVA, and pearson's correlation coefficient. Results: There was significant relationship between perceived health status and HbA1c (r=-.252, p=.015). There was significant relationship between self management and HbA1c (r=-.279, p=.007). Conclusion: In order to control blood glucose in the type II diabetes patients, it is necessary to develop supportive self management programs by considering perceived health status.