• Title/Summary/Keyword: Two-way Imaging

Search Result 70, Processing Time 0.027 seconds

The Detection of Yellow Sand with Satellite Infrared bands

  • Ha, Jong-Sung;Kim, Jae-Hwan;Lee, Hyun-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.5
    • /
    • pp.403-406
    • /
    • 2006
  • An algorithm for detection of yellow sand aerosols has been developed with infrared bands. This algorithm is a hybrid algorithm that has used two methods combined. The first method used the differential absorption in brightness temperature difference between $11{\mu}m\;and\;12{\mu}m\;(BTD1)$. The radiation at $11{\mu}m$ is absorbed more than at $12{\mu}m$ when yellow sand is loaded in the atmosphere, whereas it will be the other way around when cloud is present. The second method uses the brightness temperature difference between $3.7{\mu}m\;and\;11{\mu}m(BTD2)$. This technique is sensitive to dust loading, which the BTD2 is enhanced by reflection of $3.7{\mu}m$ solar radiation. First the Principle Component Analysis (PCA), a form of eigenvector statistical analysis from the two methods, is performed and the aerosol pixel with the lowest 10% of the eigenvalue is eliminated. Then the aerosol index (AI) from the combination of BTD 1 and 2 is derived. We applied this method to Multi-functional Transport Satellite-l Replacement (MTSAT-1R) data and obtained that the derived AI showed remarkably good agreements with Ozone Mapping Instrument (OMI) AI and Moderate Resolution Imaging Spectroradiometer (MODIS) aerosol optical depth.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Comparison of Relative Value on Physician Payment Schedule for reimbursement of health insurance between Korea and U.S.A. (한국과 미국의 기술료에 대한 상대가치 비교)

  • 김한중;조우현;손명세;박은철
    • Health Policy and Management
    • /
    • v.2 no.1
    • /
    • pp.1-16
    • /
    • 1992
  • This study compares the physician payment of national fee schedule for Korean Medical Insurance with that of the United States based on Resource Based Relative Value Scales (RBRVS) which Hsiao developed in 1988 for the Medicare reimbursement. Through the comparison of two fees schedules, this study is purposed to evaluate the appropriateness of relative values which assigned to each physician services of Korean fee schedule. A total of 264 physician services are selected for the comparison. The ratio of Korean schedule to RBRVS is selected as an index of appropriateness. It the score of index shows large variation among services, the relative value of Korean fee schedule is inappropriate with U.S. RBRVS which was developed recently. The Ratios of Korean schedule to RBRVS are widly variated ; the range of those is 8.1 to 379.3. In subgroups which are regrouped to controll systematic differences between two national fee schedules, these ratios are also variated. Services which are relatively less compensated are management/evaluation services, while services which are relatively more compensated are invasive and imaging services. By the way, the service classification of Korean fee schedule is unclear, specially in management/evalutaion services. Therefore, Korean Medical Insurance fee schedule should be modified to be more balanced and rational.

  • PDF

Reverse-time migration using the Poynting vector (포인팅 벡터를 이용한 역시간 구조보정)

  • Yoon, Kwang-Jin;Marfurt, Kurt J.
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.102-107
    • /
    • 2006
  • Recently, rapid developments in computer hardware have enabled reverse-time migration to be applied to various production imaging problems. As a wave-equation technique using the two-way wave equation, reverse-time migration can handle not only multi-path arrivals but also steep dips and overturned reflections. However, reverse-time migration causes unwanted artefacts, which arise from the two-way characteristics of the hyperbolic wave equation. Zero-lag cross correlation with diving waves, head waves and back-scattered waves result in spurious artefacts. These strong artefacts have the common feature that the correlating forward and backward wavefields propagate in almost the opposite direction to each other at each correlation point. This is because the ray paths of the forward and backward wavefields are almost identical. In this paper, we present several tactics to avoid artefacts in shot-domain reverse-time migration. Simple muting of a shot gather before migration, or wavefront migration which performs correlation only within a time window following first arriving travel times, are useful in suppressing artefacts. Calculating the wave propagation direction from the Poynting vector gives rise to a new imaging condition, which can eliminate strong artefacts and can produce common image gathers in the reflection angle domain.

Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

  • Rabelo, Katharina Alves;Cavalcanti, Yuri Wanderley;de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Campos, Paulo Sergio Flores;de Andrade Freitas Oliveira, Luciana Soares;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.189-197
    • /
    • 2017
  • Purpose: To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Materials and Methods: Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P<.05. Results: There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (P<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos(P>.05). Conclusion: Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

Reverse-time Migration for VTI and TTI Media (VTI 및 TTI 매질에서의 역시간 구조보정)

  • Kwak, Na-Eun;Min, Dong-Joo;Bae, Ho-Seuk
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.3
    • /
    • pp.191-202
    • /
    • 2011
  • Reserve-time migration (RTM) using a two-way wave equation is one of the most accurate migration techniques. RTM has been conducted by assuming that subsurface media are isotropic. However, anisotropic media are commonly encountered in reality. Conventional isotropic RTM may yield inaccurate results for anisotropic media. In this paper, we develop RTM algorithms for vertical transversely isotropic media (VTI) and tilted transversely isotropic media (TTI). For this, the pseudo-acoustic wave equations are used. The modeling algorithms are based on the high-order finite-difference method (FDM). The RTM algorithms are composed using the cross-correlation imaging condition or the imaging condition using virtual sources. By applying the developed RTM algorithms to the Hess VTI and BP TTI models, we could obtain better images than those obtained by the conventional isotropic RTM.

Tidal Stripping Substructure on Spatial Distribution of Stars in Several Globular Clusters from UKIRT Observation

  • Sohn, Young-Jong;Chun, Sang-Hyun;Kang, Minhee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.78.1-78.1
    • /
    • 2013
  • The hierarchical model of galaxy formation predicts that galaxy halos contain merger relics in the form of long stellar stream. Thus, tidal substructure of stars around globular clusters, such as tidal tails, could be an essential evidence of the merging scenario in the formation of the Galaxy. From April 2010 to December 2012, we obtained $45^{\prime}{\times}45^{\prime}$ wide-field JHKs near-infrared photometric imaging data for about 20 globular clusters in the Milky Way, and examined the stellar density distribution around globular clusters. Here, we introduce the preliminary results of stellar spatial distributions and radial surface density profiles of four globular clusters. In order to minimize the field star contamination and identify the cluster's member candidates stars, we used a statistical filtering algorithm and gave weights on the CMDs of globular clusters. In two-dimensional stellar density maps, we could found tidal stripping structures for some globular clusters. The orientation of tidal substructure seems to associate with the effects of dynamical interactions with the Galaxy and cluster's orbit. Indeed, the radial surface density profile accurately describes this stripping structures as a break in the slope of profile. The observational results could give us further observational evidence of merging scenario of the formation of the Galaxy.

  • PDF

Symptomatic Tarlov's Cyst(Sacral Meningeal Cyst) - Case Report - (신경근 압박증상을 동반한 Tarlov씨 낭종 2예 - 증 례 보 고 -)

  • Lim, Kang-Taek;Cho, Byung Moon;Shin, Dong-Ik;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.569-573
    • /
    • 2000
  • Spinal meningeal cyst of the sacrum is uncommon congenital lesion. We experienced two cases of sacral meningeal cyst, so called Tarlov's cyst, who presented with radiating pain. Magnetic resonance imaging is a highly effective way of locating and approximating the size of these entities, which generally appear as intraspinal masses of low intensity on T1-weighted and high intensity on T2-weighted images, similar to cerebrospinal fluid(CSF). We evaluated 2 patients who had Tarlov's cyst diagnosed with conventional MRI. The clinical features, radiological findings, gross appearances of the lesion at surgery, surgical technique, histopathological features of the cyst wall, and surgical outcome are described. We conclude that excellent result can be expected in the case of symptomatic Tarlov's cyst by surgical decompression.

  • PDF

Camera pose estimation framework for array-structured images

  • Shin, Min-Jung;Park, Woojune;Kim, Jung Hee;Kim, Joonsoo;Yun, Kuk-Jin;Kang, Suk-Ju
    • ETRI Journal
    • /
    • v.44 no.1
    • /
    • pp.10-23
    • /
    • 2022
  • Despite the significant progress in camera pose estimation and structure-from-motion reconstruction from unstructured images, methods that exploit a priori information on camera arrangements have been overlooked. Conventional state-of-the-art methods do not exploit the geometric structure to recover accurate camera poses from a set of patch images in an array for mosaic-based imaging that creates a wide field-of-view image by sewing together a collection of regular images. We propose a camera pose estimation framework that exploits the array-structured image settings in each incremental reconstruction step. It consists of the two-way registration, the 3D point outlier elimination and the bundle adjustment with a constraint term for consistent rotation vectors to reduce reprojection errors during optimization. We demonstrate that by using individual images' connected structures at different camera pose estimation steps, we can estimate camera poses more accurately from all structured mosaic-based image sets, including omnidirectional scenes.

Study to Protocol of PET Acquisition Time for Patient Body Type in PET/CT (PET/CT 검사에서 환자체형에 따른 적정검사 프로토콜에 관한 고찰)

  • Cho, Seok Won;Ham, Joon-Chul;Kang, Chun Goo;Bahn, Young Kag;Lee, Seung Jae;Lim, Han Sang;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.72-77
    • /
    • 2013
  • Purpose: Whole-body PET using radiopharmaceutical is one of the imaging study methods for physiological changes of body. High specificity of the PET-CT examination is used to detect an early stages of cancer and metastatic cancer by imaging a physiological changes. During the imaging process, PET image has been characterized by a relatively low image quality due to its low sensitivity and the acquisition of random and scatter coincidences as well as patients figure. Therefore, the image quality as the changes of the acquisition times of patient weight was evaluated in this study. Materials and Methods: Thirty patients who presented to our hospital were enrolled. They were divided to normal, overweight, and obese group using BMI index, respectively. The patients with a liver disease and diabetes were excluded. $^{18}F-FDG$ was administered to the patients as 5.2 MBq per kg. After an hour from an injection, image acquisition was obtained as List mode in a part of liver in 1 bed. SNR (signal-to-noise ratio) of each groups acquisition times were confirmed from the calculated radiation counts and random fractions. The statistical significance of three groups was confirmed through one-way ANOVA test. On the basis of the counts of 2 minutes on normal group, the SNR of overweight group and obese group were compared. Results: The SNR were increased with loger aquisition time in 3 groups. In the condition of same acquisition time, the SNR had a statistical significance (P<0.05). The SNR were decreased to the normal, overweight, and obese, respectively. Liver activity had no significance difference on each group and RF had the significance differences (P<0.05). On the basis of the counts of 2 minutes on normal group, there were no statistical significance in a three minute acquisitions of overweight group and two minute acquisitions of obese group (P=0.150). Conclusion: In this study, the administrated amount of radiation dose did not adjust as the change of the patients weight. Increasing the acquisition time when the administration of the same amount of dose was able to get a good result of SNR. When the Based 2 minute on normal group, if overweight and obese case the increased acquisition time of 3 minute was able to obtain a similar SNR. On the basis of the normal group, the acquisition times of overweight and obese group were increased to 3 minutes per bed and the SNR were similar to the normal group.

  • PDF