• 제목/요약/키워드: Two-step self-etch

Search Result 18, Processing Time 1.465 seconds

Effects of Artificial Saliva Contamination on the Bond Strength of Three Dentin Adhesives to Dentin of Primary Teeth (인공타액오염이 유치 상아질에서 3종 상아질 접착제의 결합 강도에 미치는 영향)

  • Bae, Youngeun;Kim, Shin;Jeong, Teasung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.72-81
    • /
    • 2017
  • The aim of this study was to evaluate the effectiveness of artificial saliva contamination and decontamination procedures at different stages of a bonding procedure on the microtensile bond strength (MTBS) of two one-step self-etch adhesives and a two-step total-etch adhesive to dentin of primary teeth. Forty-two extracted sound primary molars were randomly divided into three groups depending on three adhesives, Scotchbond Universal Adhesive (SBU), All-Bond Universal (ABU) and Prime & Bond NT (PNT). For each adhesive, the teeth were allocated into seven groups. Except for control group, group 1, the groups were contaminated with artificial saliva at three different stages: the groups 2 and 3 - before adhesive application; the groups 4 and 5 - before adhesive polymerization; the groups 6 and 7 - after adhesive polymerization. Decontaminating procedures were rinsing, air-drying (group 2, 4, 6) and air-drying (group 3, 5, 7). The specimens were restored with composite resin (Filtek, Z350) and microtensile bond strength was measured. The data was analyzed with one-way ANOVA and Tukey HSD test (p < 0.05). In the control group, using PNT resulted in significantly higher bond strength than when ABU and SBU were used (p < 0.001). For three adhesives, the groups 2, 4 and 6 had greater bond strength than the groups 3, 5 and 7. Also, when the artificial saliva was contaminated before adhesive polymerization (group 4, 5), it showed a significantly lower bond strength. Generally the two-step total-etch adhesive generated a higher bond strength than the one-step self-etch adhesive. Artificial saliva contamination before adhesive polymerization led to a drastic decrease in bond strength, and rinsing with water followed by air-drying could not recover the bond strength.

MICRO-TENSILE BONDING STRENGTH OF REGIONAL PRIMARY MOLAR DENTIN (유구치 상아질의 각 부위에 적용된 수종의 복합레진 접착제의 미세인장접착강도에 관한 연구)

  • You, Jung-Eun;Choi, Yeong-Chul;Chio, Sung-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.348-357
    • /
    • 2009
  • The purpose of this study was to evaluate the micro-tensile bond strength (${\mu}TBS$) of four luting resin to regional dentin of human primary teeth. Dentin from non-carious primary molars were prepared from different regions (s, superficial dentin; d, deep dentin; c, cervical dentin), and divided into groups based on anatomical locations and types of luting resins (Scotchbond Multi-purpose : SB ; One-Step : OS ; AdheSE Bond : ASE ; G-Bond : GB) : SB-s, SB-d, SB-c; OS-s, OS-d, OS-c; ASE-s, ASE-d, ASE-c ; GB-s, GB-d, GB-c. Luting resins were used according to the manufacturers' instructions, to bond $Light-Core^{TM}$ Core Build-Up Composite) to the exposed dentin specimens in the light-curing mode. After storage for 1 day, ${\mu}TBS$ was tested at a cross-head speed of 1 mm/min. Data were analyzed with T-test and two-way ANOVA. The bonding interface and fractography analyses were performed with SEM. The results were as follows : 1. ${\mu}TBS$ to superficial dentin was significantly higher than to deep dentin for SB(p<0.05). But there were no significant differences in regional ${\mu}TBS$ among OS, ASE, GB(p>0.05). 2. There were no significant differences in ${\mu}TBS$ to superficial dentin among each groups. But, in deep dentin, ${\mu}TBS$ of SB-d was significantly lower than those of OS-d, ASE-d, and GB-d(p<0.05). ${\mu}TBS$ of OS-d was significantly higher than those of GB-d(p<0.05), but there were no significant differences in ${\mu}TBS$ of ASEd. There were no significant differences among ${\mu}TBS$ of ASE-d, OS-d, and GB-d.

  • PDF

Design, Fabricaiton and Testing of a Piezoresistive Cantilever-Beam Microaccelerometer for Automotive Airbag Applications (에어백용 압저항형 외팔보 미소 가속도계의 설계, 제작 및 시험)

  • Ko, Jong-Soo;Cho, Young-Ho;Kwak, Byung-Man;Park, Kwan-Hum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.408-413
    • /
    • 1996
  • A self-diagnostic, air-damped, piezoresitive, cantilever-beam microaccelerometer has been designed, fabricated and tested for applications to automotive electronic airbag systems. A skew-symmetric proof-mass has been designed for self-diagnostic capability and zero transverse sensitivity. Two kinds of multi-step anisotropic etching processes are developed for beam thickness control and fillet-rounding formation, UV-curing paste has been used for sillicon-to-glass bounding. The resonant frequency of 2.07kHz has been measured from the fabricated devices. The sensitivity of 195 $\mu{V}$/g is obtained with a nonlinearity of 4% over $\pm$50g ranges. Flat amplitude response and frequency-proportional phase response have been obserbed, It is shown that the design and fabricaiton methods developed in the present study yield a simple, practical and effective mean for improving the performance, reliability as well as the reproducibility of the accelerometers.

THE EFFECT OF Er,Cr:YSGG IRRADIATION ON MICROTENSILE BOND STRENGTH OF COMPOSITE RESIN RESTORATION (Er,Cr:YSGG 조사가 복합레진 수복의 미세인장 결합강도에 미치는 영향)

  • Son, Jeong-Hye;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.134-142
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of Er,Cr:YSGG laser irradiation with hypersensitivity mode on microtensile bond strength of composite resin. Twenty extracted permanent molars were randomly assigned to six groups, according to the irradiation of Er,Cr:YSGG laser, adhesive system (Optibond FL or Clearfil SE bond) and application time of etchant (15 sec or 20 sec). Then composite resin was build up on each conditioned surface. The restored teeth were stored in distilled water at room temperature for 24 h and twelve specimens for each group were prepared. All specimens were subjected to microtensile bond strength and the fracture modes were evaluated. Also, the prepared dentin surface and laser irradiated dentin surface were examined under SEM. The results were as follows: 1. The microtensile bond strength of laser irradiated group was lower than that of no laser irradiated group. 2. Regardless of laser irradiation, the microtensile bond strength of Optibond FL was higher than that of Clearfil SE bond. And the microtensile bond strength of 20 sec etching group was higher than that of 15 sec etching group when using Optibond FL. 3. The SEM image of laser irradiated dentin surface showed prominent peritubular dentin, opened dentinal tubules and no smear layer.

Microshear bond strength of a flowable resin to enamel according to the different adhesive systems (접착시스템의 종류에 따른 유동성 레진과 법랑질의 미세전단 결합강도)

  • Kim, Jeong-Ho;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • Objectives: The purpose of this study was to compare the microshear bond strength (uSBS) of two totaletch and four self-etch adhesive systems and a flowable resin to enamel. Materials and Methods: Enamels of sixty human molars were used. They were divided into one of six equal groups (n = 10) by adhesives used; OS group (One-Step Plus), SB group (Single Bond), CE group (Clearfil SE Bond), TY group (Tyrian SPE/One-Step Plus), AP group (Adper Prompt L-Pop) and GB group (G-Bond). After enamel surfaces were treated with six adhesive systems, a flowable composite resin (Filek Z 350) was bonded to enamel surface using Tygon tubes. the bonded specimens were subjected to uSBS testing and the failure modes of each group were observed under FE-SEM. Results: 1. The uSBS of SB group was statistically higher than that of all other groups, and the uSBS of OS, SE and AP group was statistically higher than that of TY and GB group (p < 0.05). 2. The uSBS for TY group was statistically higher than that for GB group (p < 0.05). 3. Adhesive failures in TY and GB group and mixed failures in SB group and SE group were often analysed. One cohesive failure was observed in OS, SB, SE and AP group, respectively. Conclusions: Although adhesives using the same step were applied the enamel surface, the uSBS of a flowable resin to enamel was different.

Effect of Er:YAG lasing on the dentin bonding strength of two-step adhesives (2단계 접착제의 상아질 결합강도에 대한 Er:YAG 레이저 조사 영향)

  • Song, Byeong-Choon;Cho, Young-Gon;Lee, Myung-Seon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.409-418
    • /
    • 2011
  • Objectives: The purpose of this study was to compare the microshear bond strength (${\mu}$SBS) and bonding interfaces of two-step total-etching and self-etching adhesive systems to three etch types of dentin either the acid etched, laser etched or laser and acid etched. Materials and Methods: The occlusal dentinal surfaces of thirty human molars were used. They were divided into six groups: group 1, 37% $H_3PO_4$ + Single Bond 2 (3M ESPE); group 2, Er:YAG laser (KEY Laser 3, KaVo) + Single Bond 2; group 3, Er:YAG laser + 37% $H_3PO_4$ + Single Bond 2; group 4, Clearfil SE Primer + Bond (Kuraray); group 5, Er:YAG laser + Clearfil SE Bond; group 6, Er:YAG laser + Clearfil SE Primer + Bond. The samples were subjected to ${\mu}$SBS testing 24 hr after bonding. Also scanning microscopic evaluations were made on the resin-dentin interfaces of six specimens. Results: The ${\mu}$SBS of group 2 was significantly lower than that of groups 1 and 3 in Single Bond 2 (p < 0.05). There were significant differences among the uSBS of groups 4, 5, and 6 in Clearfil SE Bond (p < 0.05). Very short and slender resin tags were observed in groups 2 and 5. Long and slender resin tags and lateral branches of tags were observed in groups 3 and 6. Conclusions: Treatment of dentin surface using phosphoric acid or self-etching primer improved the adhesion of Er:YAG lased dentin.

Comparison of the elastic modulus among three dentin adhesives before and after thermocycling (열시효 처리에 따른 상아질 접착 계면의 탄성계수의 변화 비교)

  • Chang, Ju-Hea;Lee, In-Bog;Cho, Byeong-Hoon;Kim, Hae-Young;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • The purpose of this study was to determine the effects on the elastic moduli of the adhesive and the hybrid layer from thermocycling. Twenty one human molars were used to create flat dentin surfaces. Each specimen was bonded with a light-cured composite using one of three commercial adhesives (OptiBond FL [OP], Clearfil SE Bond [CL], and Xeno III [XE]). These were sectioned into two halves and subsequently cut to yield 2-mm thickness specimens; one specimen for immediate bonding test without thermocycling and the other subjected to 10,000 times of thermocycling. Nanoindentation test was performed to measure the modulus of elasticity of the adhesive and the hybrid layer, respectively, using an atomic force microscope. After thermocycling, XE showed a significant decrease of the modulus in the adhesive layer (p < 0.05). Adhesives containing hydrophilic monomers are prone to hydrolytic degradation. It may result in the reduced modulus of elasticity, which leads to the mechanically weakened bonding interface.

Shear bond strength between universal adhesives with various pH and dual-cured resin cements (다양한 pH를 가지는 Universal adhesives와 이원 중합 레진 세멘트 간의 전단결합강도)

  • Kwon, Sung-Joo;Park, Jeong-Kil;Son, Sung-Ae
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.301-310
    • /
    • 2018
  • The purpose of this study is to evaluate the compatibility of universal adhesives with two dual-cured resin cements. Eighty human molars were divided into eight groups. Tooth was embedded in self-curing acrylic resin and sectioned horizontally to exposure dentine surface. After polishing with 600-grit SiC paper, adhesives were applied. All-Bond Universal (Bisco), G-premio bond (GC), Scotch-bond universal (3M ESPE), Scotch-bond Multipurpose (3M ESPE) were used in this study. Calibra (Dentsply) as a conventional dual-curing resin cement and RelyX Ultimate (3M ESPE) as an amine free resin cement were used. The adhesives and the cements were applied according to the manufacturer's instructions. Final specimens were cylinder (diameter 2mm, height 3mm) shape. After storing in distilled water at $37^{\circ}C$ for 7 days the shear bond strength (SBS) test was performed. There was no significant difference in shear bond strength between the adhesives when RelyX Ultimate was used (p>0.05). However, when Calibra used with Scotch-bond Multipurpose and All-Bond Universal were used, statistically higher SBS was observed, as compared to the groups which Calibra cements with G-premio bond and Scotch-bond universal adhesive (p<0.05) were used. Within the limitations of this study, RelyX Ultimate resin cement was compatible with universal adhesives of various pH. All-Bond Universal adhesive was compatible with a resin cement containing the tertiary amine.