• 제목/요약/키워드: Two-step method

검색결과 2,404건 처리시간 0.023초

양호교사에 의한 학생(學生) 신체검사(身體檢査) 능력(能力)에 관한 평가(評價) (A Study on the analysis of physical assessment by school nurses)

  • 김화중
    • 한국학교보건학회지
    • /
    • 제1권1호
    • /
    • pp.148-159
    • /
    • 1988
  • For the evaluation of physical assessment by school nurses, this study was designed in two steps physical assessment. The first step is the primary health screening by school health nurses. The second step is the Physicians' physical examination of ill health students selected by school nurses. This study was conducted on a total of 3,525 students of three primary schools located in urban, township, and rural area during the period from May to June, 1987, all data were collected through direct observation & survey method. The main findings are as follows 1. The number of ill health students selected by two step method was more than that of one step method by the physician. 2. The types of ill health students selected by two step method had more diversity than that of one step method by the physician. 3. Budgets and time consumption for two step method were more reductive than that of one step method by the physician.

  • PDF

Estimation of Spatial Dependence with GEE

  • Lee, Yoon-Dong;Choi, Hye-Mi
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.269-273
    • /
    • 2003
  • We consider an efficient parametric estimation method of spatial dependence in weak stationary processes. Spatial dependence is modeled through variogram and correlogram. Most of parametric estimation methods of correlogram use two step method; nonparametric estimation and parametric integration. We bind these two steps into one step by using GEE method instead of least squares type optimization. Our one step method is more efficient statistically and gives a clear interpretation of related concepts used in traditional two step methods.

  • PDF

자동차 내장용 직물의 난연 및 발수가공 (Flame-Retardant and Water-Repellent Finishing of Automobile Indoor Fabrics)

  • 박병기;이방원;김환철;김학용
    • 한국염색가공학회지
    • /
    • 제11권5호
    • /
    • pp.7-12
    • /
    • 1999
  • The objective of this study is to apply water repellent and flame retardant finishes simultaneously to the fabric used for automobile. Both two step and one step methods were tried to apply the finishing agent to the fabric. In the two step method, water repellent agent was treated first, and flame retardant agent was applied next. The reverse finishing process was also attempted. In the one step method, flame retardant agent and water repellent agent treated to the fabric in one bath. The results of two step method revealed that the finishing effect was better when the water repellent agent was treated first than when flame retardant agent was treated first. In one step method, fluoro water repellent agent was superior to silicon water repellent agent.

  • PDF

양모/카티온화 면 혼방품의 산성염료/반응성염료에 의한 1욕2단 염색에 관한 연구 (Studies on the One Bath Two Step Dyeing of Wool/Cationized Cotton Blends with Acid Dye/Reactive Dye)

  • 성우경;이춘길;권오경
    • 한국염색가공학회지
    • /
    • 제11권2호
    • /
    • pp.46-54
    • /
    • 1999
  • The conventional dyeing of wool/cotton blends involves a two bath two step method, i.e., after dyeing of the wool component with acid dyes in an acidic dyebath at $100^\circ{C}$, the dyeing of the cotton component with reactive dyes in an alkaline dyebath is performed. In order to overcome the disadvantage of the conventional two bath two step dyeing method of wool/cotton blends, it had prompted significant effort to the development of the one bath dyeing method which can accomplish savings in time, energy and water usage. To improve dyeing property of wool/cotton blends, cotton component was pretreated with cationizing agent containing chlorohydrine group in aqueous solution of sodium hydroxide. This study was carried out to investigate dyeing possibilities of wool/cationized cotton blends with acid dye/reactive dye by one bath two step method.

  • PDF

Development of uncertainty quantification module for VVER analysis in STREAM/RAST-V two-step method

  • Jaerim Jang;Yunki Jo;Deokjung Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권8호
    • /
    • pp.3276-3285
    • /
    • 2024
  • This paper introduces the creation of a module for Uncertainty Quantification (UQ) specifically designed for VVER analysis through the implementation of the STREAM/RAST-V two-step approach. The aim was to expand the range of use by developing a UQ module tailored for analyzing VVER. This research presents two innovative computational functionalities: (1) development of a library for the pin-based pointwise energy slowing down method (PSM), and (2) extension of the analysis area to study hexagonal-geometry fuel assemblies. The proposed UQ scheme was evaluated through verification using UAM benchmark, and comparative analysis between codes using SCALE 6.2.2 for. STREAM provides an accuracy comparable to that of SCALE 6.2.2. Additionally, a PSM covariance library was utilized in the calculations, achieving 0.7941% and 0.7907% accuracies in the hot full power and hot zero power calculations, respectively. To assess the UQ sequences in the two-step method, the STREAM/RAST-V calculation scheme was verified using the STREAM lattice code. To conclude, this study furnishes comprehensive insights into the development of the UQ module within the two-step method for VVER analysis, and it validates its performance through utilization of the UAM benchmark.

실험에 적합한 직교 배열표의 자동 생성 및 2 단계 구조 최적화에의 적용 (Automatic Generation of Orthogonal Arrays and Its Application to a Two-Step Structural Optimization)

  • 이수범;곽병만
    • 대한기계학회논문집A
    • /
    • 제27권12호
    • /
    • pp.2047-2054
    • /
    • 2003
  • In this paper, an approach of automatically finding and modifying the most appropriate orthogonal array (GO) is suggested and applied to a new structural optimization procedure with two steps. GO is motivated by the situation where finding a proper orthogonal array from the tables in the literature is difficult or impossible. Now the Taguchi method is made available for various numbers of variables and levels. In the two-step structural optimization, the Taguchi method equipped with GO and a shape optimization using the finite differencing method is consecutively applied. The existence or non-existence of an element can be taken as a factor level and this feature is utilized finding the best topology from a set of potential topologies suggested from the user's expertise. This greatly enhances applicability and one can expect a better result than the case in which each step is applied independently because these steps are complementary each other.

필기체 한글의 오프라인 인식을 위한 효과적인 두 단계 패턴 정합 방법 (Efficient two-step pattern matching method for off-line recognition of handwritten Hangul)

  • 박정선;이성환
    • 전자공학회논문지B
    • /
    • 제31B권4호
    • /
    • pp.1-8
    • /
    • 1994
  • In this paper, we propose an efficient two-step pattern matching method which promises shape distortion-tolerant recognition of handwritten of handwritten Hangul syllables. In the first step, nonlinear shape normalization is carried out to compensate for global shape distortions in handwritten characters, then a preliminary classification based on simple pattern matching is performed. In the next step, nonlinear pattern matching which achieves best matching between input and reference pattern is carried out to compensate for local shape distortions, then detailed classification which determines the final result of classification is performed. As the performance of recognition systems based on pattern matching methods is greatly effected by the quality of reference patterns. we construct reference patterns by combining the proposed nonlinear pattern matching method with a well-known averaging techniques. Experimental results reveal that recognition performance is greatly improved by the proposed two-step pattern matching method and the reference pattern construction scheme.

  • PDF

A Simple Volume Tracking Method For Compressible Two-Phase Flow

  • SHYUE KEH-MING
    • 천문학회지
    • /
    • 제34권4호
    • /
    • pp.237-241
    • /
    • 2001
  • Our goal is to present a simple volume-of-fluid type interface-tracking algorithm to compressible two-phase flow in two space dimensions. The algorithm uses a uniform underlying Cartesian grid with some cells cut by the tracked interfaces into two subcells. A volume-moving procedure that consists of two basic steps: (1) the update of volume fractions in each grid cell at the end of the time step, and (2) the reconstruction of interfaces from discrete set of volume fractions, is employed to follow the dynamical behavior of the interface motion. As in the previous work with a surface-tracking procedure for general front tracking (LeVeque & Shyue 1995, 1996), a high resolution finite volume method is then applied on the resulting slightly nonuniform grid to update all the cell values, while the stability of the method is maintained by using a large time step wave propagation approach even in the presence of small cells and the use of a time step with respect to the uniform grid cells. A sample preliminary numerical result for an underwater explosion problem is shown to demonstrate the feasibility of the algorithm for practical problems.

  • PDF

CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구 (A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results)

  • 안재석;김지나;박광서;주은빛;윤상혁;김윤철
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.81-87
    • /
    • 2024
  • Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents. Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent. Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value. Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.

Application of Hyperbolic Two-fluids Equations to Reactor Safety Code

  • Hogon Lim;Lee, Unchul;Kim, Kyungdoo;Lee, Won-Jae
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.45-54
    • /
    • 2003
  • A hyperbolic two-phase, two-fluid equation system developed in the previous work has been implemented in an existing nuclear safety analysis code, MARS. Although the implicit treatment of interfacial pressure force term introduced in momentum equation of the hyperbolic equation system is required to enhance the numerical stability, it is very difficult to implement in the code because it is not possible to maintain the existing numerical solution structure. As an alternative, two-step approach with stabilizer momentum equations has been selected. The results of a linear stability analysis by Von-Neumann method show the equivalent stability improvement with fully-implicit solution method. To illustrate the applicability, the new solution scheme has been implemented into the best-estimate thermal-hydraulic analysis code, MARS. This paper also includes the comparisons of the simulation results for the perturbation propagation and water faucet problems using both two-step method and the original solution scheme.