Novel Dual DC-DC Flyback Converter with Leakage-Energy Recycling

  • Yang, Lung-Sheng
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1007-1014
    • /
    • 2018
  • A novel dual DC-DC flyback converter with leakage-energy recycling is presented in this paper. Only an active switch is used for this converter. A pulse-width-modulation strategy is adopeted to control this switch. Two transformers are employed for the proposed converter. During the switch ON-period, the primary windings of the two transformers store energies. At the switch OFF-period, the energies stored in the primary windings of the two transformers are released to the output via the secondary windings of the two transformers. Meanwhile, the leakage energies of the two transformers can be recycled. The operating principles and steady-state analyses of the proposed converter are described in detail. A prototype circuit of the proposed converter is implemented for verifying the performances.

배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석 (Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers)

  • 안정식;최순호;방정주;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

실시간 감시를 이용한 배전용변압기 과부하 평가 시스템 개발 (Development of Overload Evaluation System of Distribution Transformers using Real-Time Monitoring)

  • 박창호;윤상윤
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1741-1747
    • /
    • 2010
  • The development of overload management systems for distribution transformers offers new opportunities for improving the reliability of distribution systems. It allows network planners to optimize the system resource utilization and investment cost. Such an improvement in the flexibility of the distribution network is only possible if the operator has more accurate knowledge of the realtime conditions of distribution transformers. In this paper, we present an improved overload decision system for distribution transformers using realtime monitoring data. Our study can be categorized into two parts: (a) improvement in the criteria for judging the overload conditions of distribution transformers and (b) development of an overload evaluation system using realtime monitoring data. In order to determine the overload criteria, overload experiments are performed on sample transformers; the results of these experiments are used to define the relationship between the transformer overload and the increase in the top-oil temperature. To verify the accuracy of the experimental results, field tests are performed using specially manufactured transformers, the loads and top-oil temperatures of which can be measured. For arriving at online overload decisions, we propose methods whereby the measured load curve can be converted into an overload characteristic curve and the overload time can be calculated for any load condition. The developed system is able to evaluate the overload for individual distribution transformers and calculate the losses using realtime monitoring data.

두 대의 LLT 변압기 적용 LLC 직렬 공진 컨버터 (LLC Series Resonant Converter with two Transformers)

  • 강성인;김주훈;김은수;박준호;허동영;정용채
    • 전력전자학회논문지
    • /
    • 제14권6호
    • /
    • pp.431-439
    • /
    • 2009
  • 본 논문에서는 두 대의 LLT 변압기 적용 LLC 직렬공진 컨버터의 입출력 이득 특성 및 설계과정에 대하여 서술 하였다. 적용된 두 대의 변압기 1차측은 직렬로 연결하고, 변압기 2차측은 병렬로 연결 하여 변압기 1차측 전류 불균형이 없도록 하였다. 부하 변동과 전압이득 특성을 고려하여 이론적 분석 및 시뮬레이션 결과를 토대로 50인치 PDP TV전원을 위한 400W 시제품을 제작 실험하여 설계 절차의 타당성을 검증하였다.

변압기 병렬운전시 순환전류 추정 (Estimation of the circulating currents in the parallel operation of transformers)

  • 강용철;이미선;이병은;장성일;김용균;주행로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.23-24
    • /
    • 2008
  • For the $Y-Y-{\Delta}$ transformers operated in parallel, there exist two kinds of the circulating currents i.e. between the tanks and between the banks of the delta side. The proposed algorithm estimates the two circulating currents in the transformers in parallel in an ultra high voltage system. As the circulating current between the tanks is 90 deg out of phase of the load current, it is estimated by decomposing the line current into the component 90 deg out of phase of the load current. The circulating current between the banks in the delta side is estimated from the delta winding current and the line currents. The performance of the proposed algorithm is investigated when the impedances of the two transformer tanks are different or the taps of the on-load tap changer of the transformers are mismatched temporarily. Test results indicate that the algorithm can estimate the two kinds of the circulating currents successfully for both cases.

  • PDF

직렬 연결된 두 개의 트랜스포머를 갖는 새로운 위상 천이 풀 브릿지 컨버터 (A New Phase Shift Full Bridge Converter with Serially Connected Two Transformers)

  • 구관본;김태성;문건우;윤명중
    • 전력전자학회논문지
    • /
    • 제7권5호
    • /
    • pp.443-452
    • /
    • 2002
  • 수 백 Watt 급의 통신용 장비 등에 적합하도록 고안된, 직렬 연결된 두 개의 트랜스포머를 갖는 새로운 위상천이 풀 브릿지 컨버터를 제시한다. 제안된 회로의 장점은 넓은 입력 범위를 가지며, 경부하에서도 스위치의 영전압 조건을 보다 쉽게 만족시킬 수 있다는 점, 그리고 작은 출력 변동율을 갖는다는 점 등이다. 뿐만 아니라, 직렬로 연결된 두 개의 트랜스포머가 번갈아 가면서 주 트랜스포머로서의 역할과 출력 인덕터로서의 역할을 함께 수행하므로, 출력측에서는 인덕터없이 필터링이 가능하게 되고, 따라서 고전력밀도의 컨버터를 제작할 수 있게 된다. 모드 해석과 대신호 모델링을 통한 설계식의 유도, 그리고 실험 결과를 보여줌으로써 제안된 컨버터를 검증한다.

2상 쵸퍼 Preregulator를 갖는 12-step 인버터에서의 DC Link단 전압 불평형 해석 (Analysis of the Unbalance of DC Link Voltage in 12-step Inverter with 2-Phase Chopper Preregulator)

  • 노의철;김인동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.258-260
    • /
    • 1995
  • This paper deals with the voltage unbalance of DC link voltage in series connected two 6-step inverters with double chopper preregulator. Each output of the 6-step inverter is connected to each transformer. The secondary windings of one of the transformers is zig-zag connected and the other star connected. The secondary terminals of the two transformers are series connected which makes 12-step output voltage waveform. In this case, the characteristics of the two transformers are rather different each other. The difference results in the voltage unbalance of the two 6-step inverter input capacitor voltages which make the DC link voltage. The degree of the voltage unbalance is analysied with the variations of load power, load power factor and % impedance of the transformer.

  • PDF

두 개의 변압기를 이용한 새로운 소프트 스위칭 방식의 DC-DC 컨버터 (A New Soft Switching DC-DC Converter using Two Transformers)

  • 이달우;안태영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.444-449
    • /
    • 2005
  • This paper proposes the new soft switching DC-DC converter. We reported the experimental results of the new soft switching DC-DC converter. The proposed converter is to resonate between the leakage inductance of the transformer and the parasitic capacitances of the main switches for zero voltage switching. The voltage stresses of the two switches are the input voltage, it can improve the efficiency and a reduced height used two transformers. Theoretical analysis of the converter along with experimental results is provided. Finally, a 3.3V/20A prototype converter operation at 100kHz is built and experimental waveform verifies the analysis.

두 개의 변압기를 이용한 전류불균형 개선 하프브리지 LLC 공진형 컨버터 (Current Unbalance Improved Half-bridge LLC Resonant Converter using the Two Transformers)

  • 유두희;정강률
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.497-507
    • /
    • 2010
  • 본 논문은 상이한 누설인덕턴스를 가진 두 개의 변압기를 이용하여 전류불균형을 개선한 하프브리지 LLC 공진형 컨버터를 제안한다. 제안된 컨버터는 변압기의 누설인덕턴스와 자화인덕턴스 및 공진커패시턴스를 이용하여 공진하고, 넓은 부하영역을 가지며, 경부하에서도 영전압스위칭 조건을 만족한다. 직/병렬로 연결된 두 개의 변압기는 동작모드에 따라 변압기 또는 공진인덕턴스로써 교대로 동작하고, 변압기 2차측에는 누설인덕턴스를 이용하므로 별도의 출력 필터인덕턴스가 필요하지 않다. 또한 제안된 컨버터는 두 변압기의 상이한 누설인덕턴스와 하프브리지 스위치의 비대칭 펄스폭변조를 이용하여 2차측 정류다이오드의 전류불균형 문제를 개선한다. 본 논문에서는 제안된 컨버터의 동작원리를 모드별로 설명하고 프로토타입 컨버터의 설계 예를 제시한다. 제안된 컨버터의 우수한 성능을 입증하기 위하여 설계된 프로토타입의 회로파라미터로써 프로토타입 컨버터를 제작하고 실험하였다. 제안된 컨버터의 우수한 성능을 실험결과를 통하여 보인다.

변압기 병렬운전시 순환전류 추정 (Estimation of the Circulating Currents in the Parallel Operation of Transformers)

  • 강용철;이미선;이병은;최재선;장성일;김용균;류영식
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2147-2152
    • /
    • 2008
  • This paper proposes an algorithm to estimate the circulating currents in the transformers in parallel in an ultra high voltage system. For the Y-Y-${\Delta}$ transformers operated in parallel, there exist two kinds of the circulating currents i.e. one is between the tanks and the other between the banks of the delta side. As the former is 90 deg out of phase of the load current, it is estimated by decomposing the line current into the component 90 deg out of phase of the load current in the frequency domain. The latter is estimated in the time domain from applying the Kirchhoff's voltage law on the delta winding which gives a first-order differential equation in terms of the delta winding currents. To estimate the circulating currents between the tanks, the performance of the proposed algorithm is investigated when the impedances of the two transformer tanks are different or the taps of the on-load tap changer of the transformers are mismatched temporarily. To estimate the circulating currents between the banks, the performance of the proposed algorithm is also examined under magnetic inrush and over-excitation. Test results indicate that the algorithm can estimate the two kinds of the circulating currents successfully.