Multi-Channel Vision System for On-Line Quantification of Appearance Quality Factors of Apple

  • Lee, Soo Hee;Noh, Sang Ha
    • Agricultural and Biosystems Engineering
    • /
    • 제1권2호
    • /
    • pp.106-110
    • /
    • 2000
  • An integrated on-line inspection system was constructed with seven cameras, half mirrors to split images. 720 nm and 970 nm band pass filters, illumination chamber having several tungsten-halogen lamps, one main computer, one color frame grabber, two 4-channel multiplexors, and flat plate conveyer, etc. A total of seven images, that is, one color image form the top of an apple and two B/W images from each side (top, right and left) could be captured and displayed on a computer monitor through the multiplexor. One of the two B/W images captured from each side is 720nm filtered image and the other is 970 nm. With this system an on-line grading software was developed to evaluate appearance quality. On-line test results with Fuji apples that were manually fed on the conveyer showed that grading accuracies of the color, defect and shape were 95.3%, 86% and 88.6%, respectively. Grading time was 0.35 second per apple on an average. Therefore, this on-line grading system could be used for inspection of the final products produced from an apple sorting system.

  • PDF

Design of the IGRINS Calibration System

  • 오희영;김강민;이성호;장비호;이상은;박수종;육인수;천무영
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.155.2-155.2
    • /
    • 2011
  • We present development of the calibration system for IGRINS (the Immersion GRating Infrared Spectrograph). We mainly use Th-Ar and U hollow cathode lamp as the spectral calibration source and telluric features can be used additionally. For the flat source, we selected a 3000K tungsten halogen lamp with 2 inch integrating sphere. From Light Tools simulation, the result flat image through calibration optics satisfied <1% flatness error requirement. We also present mechanical design of calibration box that will be attached on the IGRINS dewar. Three moving stages are designed to perform switching mechanism between all of the observing modes - target observation, flat, precision RV measurement, and spectro-polarimetric observation.

  • PDF

2단계 RTD방법에 의한 $N^+P$ 접합 티타늄 실리사이드 특성연구 (The characterization for the Ti-silicide of $N^+P$ junction by 2 step RTD)

  • 최도영;윤석범;오환술
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권6호
    • /
    • pp.737-743
    • /
    • 1995
  • Two step RTD(Rapid Thermal Diffussion) of P into silicon wafer using tungsten halogen lamp was used to fabricated very shallow n$^{+}$p junction. 1st RTD was performed in the temperature range of 800.deg. C for 60 see and the heating rate was in the 50.deg. C/sec. Phosphrous solid source was transfered on the silicon surface. 2nd RTD process was performed in the temperature range 1050.deg. C, 10sec. Using 2 step RTD we can obtain a shallow junction 0.13.mu.m in depth. After RTD, the Ti-silicide process was performed by the two step RTA(Rapid Thermal Annealing) to reduced the electric resistance and to improve the n$^{+}$p junction diode. The titanium thickness was 300.angs.. The condition of lst RTA process was 600.deg. C of 30sec and that of 2nd RTA process was varied in the range 700.deg. C, 750.deg. C, 800.deg. C for 10sec-60sec. After 2 step RTA, sheet resistance was 46.ohm../[]. Ti-silicide n+p junction diode was fabricated and I-V characteristics were measured.red.

  • PDF

MULTI-CHANNEL VISION SYSTEM FOR ON-LINE QUANTIFICATION OF APPEARANCE QUALITY FACTORS OF APPLE

  • Lee, S. H.;S. H. Noh
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.551-559
    • /
    • 2000
  • An integrated on-line inspection system was constructed with seven cameras, half mirrors to split images, 720 nm and 970 nm band pass filters, illumination chamber having several tungsten-halogen lamps, one main computer, one color frame grabber, two 4-channel multiplexors, and flat plate conveyer, etc., so that a total of seven images, that is, one color image from the top side of an apple and two B/W images from each side (top, right and left) could be captured and displayed on a computer monitor through the multiplexor. One of the two B/W images captured from each side is 720nm filter image and the other is 970nm. With this system an on-line grading software was developed to evaluate appearance quality. On-line test results to the Fuji apples that were manually fed on the conveyer showed that grading accuracies of the color, defective and shape were 95.3%, 86% and 91%, respectively. Grading time was 0.35 sec per apple on an average. Therefore, this on-line grading system could be used for inspection of the final products produced from an apple sorting system.

  • PDF

Phototoxic effect of blue light on the planktonic and biofilm state of anaerobic periodontal pathogens

  • Song, Hyun-Hwa;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok;Lee, Si-Young;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.72-78
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the phototoxic effects of blue light exposure on periodontal pathogens in both planktonic and biofilm cultures. Methods: Strains of Aggregatibacter actinomycetemcomitans, Fusobacterium nucleatum, and Porphyromonas gingivalis, in planktonic or biofilm states, were exposed to visible light at wavelengths of 400.520 nm. A quartz-tungsten-halogen lamp at a power density of $500mW/cm^2$ was used for the light source. Each sample was exposed to 15, 30, 60, 90, or 120 seconds of each bacterial strain in the planktonic or biofilm state. Confocal scanning laser microscopy (CSLM) was used to observe the distribution of live/dead bacterial cells in biofilms. After light exposure, the bacterial killing rates were calculated from colony forming unit (CFU) counts. Results: CLSM images that were obtained from biofilms showed a mixture of dead and live bacterial cells extending to a depth of $30-45{\mu}m$. Obvious differences in the live-to-dead bacterial cell ratio were found in P. gingivalis biofilm according to light exposure time. In the planktonic state, almost all bacteria were killed with 60 seconds of light exposure to F. nucleatum (99.1%) and with 15 seconds to P. gingivalis (100%). In the biofilm state, however, only the CFU of P. gingivalis demonstrated a decreasing tendency with increasing light exposure time, and there was a lower efficacy of phototoxicity to P. gingivalis as biofilm than in the planktonic state. Conclusions: Blue light exposure using a dental halogen curing unit is effective in reducing periodontal pathogens in the planktonic state. It is recommended that an adjunctive exogenous photosensitizer be used and that pathogens be exposed to visible light for clinical antimicrobial periodontal therapy.

백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측 (Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp)

  • 이흥수;김두현
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

근적외 분광법을 응용한 휴대용 벌꿀 품질 평가 장치 개발 (Development of a Portable Quality Evaluation System for Bee-honeys by Using Near Infrared Spectroscopy)

  • 최창현;김종훈;권기현;김용주
    • 한국식품저장유통학회지
    • /
    • 제18권2호
    • /
    • pp.156-164
    • /
    • 2011
  • This study was conducted to develop a portable quality evaluation system of bee-honey by near infrared spectroscopic technique. Two kinds of bee-honeys from acacia and polyflower sources were tested in this study. The system consists of power supply, tungsten-halogen lamp, detector, and optical fiber probe. Performance of the system was analyzed by comparing the prediction accuracy of the laboratory spectrophotometer. Total of 346 spectra was divided into a calibration set and a prediction set. The PLS (Partial Least Squares) models were developed to predict the quality parameters of bee-honeys. Reflectance spectra, moisture contents, ash, invert sugar, sucrose, F/G ratio, HMF(hydroxy methyl furfural), and $C^{12}/C^{13}$ ratio of honeys were measured. The PLS models of the laboratory spectrophotometer showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1.100~2.200 nm. The PLS analysis of the portable quality evaluation system showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1.100~1.300 nm and 1.400~1.700 nm. The results showed the feasibility of the portable quality evaluation system to determine the quality parameters of bee-honey in the field during harvesting.

Design of IGRINS Wavelength Calibration System

  • 오희영;박수종;육인수;박찬;이상은;천무영;김강민;이성호;표태수
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • IGRINS (the Immersion GRating Infrared Spectrograph) is a high resolution infrared spectrograph which is being developed by a collaboration of the University of Texas, the Korea Astronomy and Space Science Institute, and Kyung Hee University. The wavelength calibration unit of IGRINS will be situated between the telescope flange and IGRINS dewar. It will include Th-Ar hallow cathode lamp, optical elements, and gas absorption cell for the case that requires precise calibration (e.g., radial velocity observation). The system will also use a tungsten halogen lamp in an integrating sphere as a blackbody source for the flat-field imaging. IGRINS will be placed initially on the McDonald 2.7m Harlan J. Smith telescope and later on 4-8m class telescopes. We present an overview of the plan for the wavelength calibration sources and of the development process for the optical and mechanical design of the IGRINS calibration system.

  • PDF

제조사 보정상수에 기인한 열유속계의 측정 오차 (Measurement Bias of Heat Flux Gauge based on Calibration Constant supported by Manufacturer)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.1-6
    • /
    • 2018
  • 본 연구는 Schmidt-Boelter형 열유속계의 측정 불확실도를 정량화하기 위한 기초연구로서 제조사에서 제공되는 보정상수의 측정오차를 평가하였다. 보정실험은 미국립표준기술원(NIST) 화재연구부의 2000 W급 할로겐-텅스텐 램프를 열원으로 적용한 열유속계 보정장치를 이용하였으며 동일 열유속 조건들에 대해 보정대상 열유속계와 표준열유속계를 비교하여 보정상수를 얻었다. 3개 제조사의 열유속계에 대한 보정실험 결과를 제조사의 보정상수와 비교하였다. 열유속계의 출력신호의 섭동값은 $1{\cdot}$를 넘지 않았으며 보정실험결과와 제조사의 보정상수의 상대오차는 1.5% ~ 14.3%까지 차이를 보였다. 본 연구는 정확한 열유속을 측정하기 위해 지속적이고 주기적인 보정과정이 필요함을 보여준다.

Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units

  • Mousavinasab, Sayed-Mostafa;Khoroushi, Maryam;Moharreri, Mohammadreza;Atai, Mohammad
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.155-163
    • /
    • 2014
  • Objectives: Light-curing of resin-based materials (RBMs) increases the pulp chamber temperature, with detrimental effects on the vital pulp. This in vitro study compared the temperature rise under demineralized human tooth dentin during light-curing and the degrees of conversion (DCs) of three different RBMs using quartz tungsten halogen (QTH) and light-emitting diode (LED) units (LCUs). Materials and Methods: Demineralized and non-demineralized dentin disks were prepared from 120 extracted human mandibular molars. The temperature rise under the dentin disks (n = 12) during the light-curing of three RBMs, i.e. an Ormocer-based composite resin (Ceram. X, Dentsply DeTrey), a low-shrinkage silorane-based composite (Filtek P90, 3M ESPE), and a giomer (Beautifil II, Shofu GmbH), was measured with a K-type thermocouple wire. The DCs of the materials were investigated using Fourier transform infrared spectroscopy. Results: The temperature rise under the demineralized dentin disks was higher than that under the non-demineralized dentin disks during the polymerization of all restorative materials (p < 0.05). Filtek P90 induced higher temperature rise during polymerization than Ceram.X and Beautifil II under demineralized dentin (p < 0.05). The temperature rise under demineralized dentin during Filtek P90 polymerization exceeded the threshold value ($5.5^{\circ}C$), with no significant differences between the DCs of the test materials (p > 0.05). Conclusions: Although there were no significant differences in the DCs, the temperature rise under demineralized dentin disks for the silorane-based composite was higher than that for dimethacrylate-based restorative materials, particularly with QTH LCU.