• Title/Summary/Keyword: Tumor-to-tumor

Search Result 12,976, Processing Time 0.079 seconds

Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response (국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가)

  • Kim Hunjung;Cho Young Kap;Kim Chulsu;Kim Woo Chul;Lee Sukho;Loh J K
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • Purpose : To evaluate possible acute toxicity and early response of concurrent radiation therapy and low dose daily cisplatin as a radiosensitizer in patients with locally advanced uterine cervical carcinomas. Materials and Method : From December 1996 to January 1999, 38 previously untreated Patients with locally advanced squamous cell carcinoma of the uterine cervix (from stage IIB to stage IIIB) were treated at Inha University Hospital. All patients underwent standard pretreatment staging Procedures after the initial evaluation by gynecologists and radiation oncologists. Sixteen Patients with huge cervical mass (>4 cm) were submitted to the group treated with concurrent radiation therapy and low dose daily cisplatin while the remainder was treated with radiation therapy alone. Radiation therapy consisted of 4500 cGy external beam irradiation to whole pelvis (midline block after 3000 cGy), 900$\~$1000 cGy boost to involved parametrium, and high dose-rate intracavitary brachytherapy (a total dose of 3000$\~$3500 cGy/500 cGy per fraction to point A, twice per week). In the group treated with low dose cisplatin concurrently, 10 mg of daily intravenous cisplatin was given from the 1st day of radiation therapy to the 20th day of radiation therapy. Acute toxicity was measured according to expanded common toxicity criteria of the NCI (C) Clinical Trials. Early response data were analyzed at minimum 4 weeks' follow-up after completion of the treatment protocol. Results: Hematolgic toxici쇼 was more prominent in patients treated with radiation therapy and cisplatin. Six of 16 patients (37.5$\~$) treated with radiation therapy and cisplatin and one of 22 patients (4.5$\~$) treated with radiation therapy alone experienced grade 3 leukopenia. In Fisher's exact test, there was statistically significant difference between two groups regarding leukopenia (P=0.030). There was no apparent difference in the frequency of gastrointestinal and genitourinary toxicity between two groups (P=0.066). Three of 16 patients (18.7$\~$) treated with radiation therapy and cisplatin and two of 22 patients (9.1$\~$) treated with radiation therapy alone experienced more than 5 kg weight loss during the treatment. There was no statistically significant difference on weight loss between two groups (P=0.63). Two patients on each group were not evaluable for the early response because of incomplete treatment. The complete response rate at four weeks' follow-up was 80$\~$(16/20) for the radiation therapy alone group and 78$\~$ (11/14) for the radiation therapy and cisplatin group. There was no statistically significant difference in early response between two treatment groups (P=0.126). Conclusion : This study led to the conclusion that the hematologic toxicity from the treatment with concurrent radiation therapy and low dose daily cisplatin seems to be more prominent than that from the treatment of radiation therapy alone. There was no grade 4 hematologic toxicity or mortality in both groups. The hematologic toxicity in both treatment groups seems to be well managable modically. Since the risk factors were not balanced between two treatment groups, the direct comparison of early response of both groups was not possible. However, preliminary results regarding early response for patients with bulky cervical tumor mass treated with radiation therapy and low dose daily cisplatin was encouraging. Longer follow-up is necessary to evaluate the survival data. A phase III study is needed to evaluate the efficacy of concurrent daily low dose cisplatin with radiation therapy in bulky cervical cancer.

  • PDF

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Individualized Determination of Lower Margin in Pelvic Radiation Field after Low Anterior Resection for Rectal Cancer Resulted in Equivalent Local Control and Radiation Volume Reduction Compared with Traditional Method (하전방 절제술을 시행한 직장암 환자에서 방사선조사 영역 하연의 개별화)

  • Park Suk Won;Ahn Yong Chan;Huh Seung Jae;Chun Ho Kyung;Kang Won Ki;Kim Dae Yong;Lim Do Hoon;Noh Young Ju;Lee Jung Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.194-199
    • /
    • 2000
  • Purpose : Then determining the lower margin of post-operative pelvic radiation therapy field according to the traditional method (recommended by Gunderson), the organs located in the low pelvic cavity and the perineum are vulnerable to unnecessary radiation. This study evaluated the effect of individualized determination of the lower margin at 2 cm to 3 cm below the anastomotic site on the failure patterns. Materials and Methods . Authors included ぉ patients with modified Astler-Coiler (MAC) stages from B2 through C3, who received low anterior resection and post-operative pelvic radiation therapy from Sept. 1994 to May 1998 at Samsung Medical Center, Sungkyunkwan University. The numbers of male and female patients were 44 and 44, and the median age was 57 years (range: 32-81 years). Three field technique (posterior-anterior and bilateral portals) by 6, 10, 15 MV X-rays was used to deliver 4,500 cGy to the whole pelvis followed by Sn cGy's small field boost to the tumor bed over 5.5 weeks. Sixteen patients received radiation therapy by traditional field margin determination, and the lower margin was set either at the low margin of the obturator foramen or at 2 cm to 3 cm below the anastomotic site, whichever is lower. In 72 patients, the lower margin was set at 2 cm to 3 cm below the anastomotic site, irrespectively of the obturator foramen, by which the reduction of radiation volume was possible in 55 patients ($76\%$). Authors evaluated and compared survival, local control, and disease-free survival rates of these two groups. Results : The median follow-up period was 27 months (range : 7-58 months). MAC stages B2 in 32($36\%$), B3 in 2 ($2\%$), Cl in 2 ($2\%$), C2 in 50 ($57\%$), and C3 in 2 ($2\%$) Patients, respectively. The entire patients' overall survival rates at 2 and 4 years were $94\%$ and $68\%$, respectively, and disease-free survival rates at 2 and 4 years were $86\%$ and $58\%$, respectively. The first failure sites were local only in 4, distant only in 14, and combined local and distant in 1 patient, respectively. There was no significant difference with respect to local control and disease-free survival rates ( p=0.42, p=0.68) between two groups of different lower margin determination policies. Conclusion : The new concept in the individualized determination of the lower margin depending on the anastomotic site has led to the equivalent local control and disease-free survival rates, and is expected to contribute to the reduction of unnecessary radiation-related morbidity by reduction of radiation volume, compared with the traditional method of lower margin determination.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

The Ability of Anti-tumor Necrosis Factor Alpha(TNF-${\alpha}$) Antibodies Produced in Sheep Colostrums

  • Yun, Sung-Seob
    • 한국유가공학회:학술대회논문집
    • /
    • 2007.09a
    • /
    • pp.49-58
    • /
    • 2007
  • Inflammatory process leads to the well-known mucosal damage and therefore a further disturbance of the epithelial barrier function, resulting abnormal intestinal wall function, even further accelerating the inflammatory process[1]. Despite of the records, etiology and pathogenesis of IBD remain rather unclear. There are many studies over the past couple of years have led to great advanced in understanding the inflammatory bowel disease(IBD) and their underlying pathophysiologic mechanisms. From the current understanding, it is likely that chronic inflammation in IBD is due to aggressive cellular immune responses including increased serum concentrations of different cytokines. Therefore, targeted molecules can be specifically eliminated in their expression directly on the transcriptional level. Interesting therapeutic trials are expected against adhesion molecules and pro-inflammatory cytokines such as TNF-${\alpha}$. The future development of immune therapies in IBD therefore holds great promises for better treatment modalities of IBD but will also open important new insights into a further understanding of inflammation pathophysiology. Treatment of cytokine inhibitors such as Immunex(Enbrel) and J&J/Centocor(Remicade) which are mouse-derived monoclonal antibodies have been shown in several studies to modulate the symptoms of patients, however, theses TNF inhibitors also have an adverse effect immune-related problems and also are costly and must be administered by injection. Because of the eventual development of unwanted side effects, these two products are used in only a select patient population. The present study was performed to elucidate the ability of TNF-${\alpha}$ antibodies produced in sheep colostrums to neutralize TNF-${\alpha}$ action in a cell-based bioassay and in a small animal model of intestinal inflammation. In vitro study, inhibitory effect of anti-TNF-${\alpha}$ antibody from the sheep was determined by cell bioassay. The antibody from the sheep at 1 in 10,000 dilution was able to completely inhibit TNF-${\alpha}$ activity in the cell bioassay. The antibodies from the same sheep, but different milkings, exhibited some variability in inhibition of TNF-${\alpha}$ activity, but were all greater than the control sample. In vivo study, the degree of inflammation was severe to experiment, despite of the initial pilot trial, main trial 1 was unable to figure out of any effect of antibody to reduce the impact of PAF and LPS. Main rat trial 2 resulted no significant symptoms like characteristic acute diarrhea and weight loss of colitis. This study suggested that colostrums from sheep immunized against TNF-${\alpha}$ significantly inhibited TNF-${\alpha}$ bioactivity in the cell based assay. And the higher than anticipated variability in the two animal models precluded assessment of the ability of antibody to prevent TNF-${\alpha}$ induced intestinal damage in the intact animal. Further study will require to find out an alternative animal model, which is more acceptable to test anti-TNF-${\alpha}$ IgA therapy for reducing the impact of inflammation on gut dysfunction. And subsequent pre-clinical and clinical testing also need generation of more antibody as current supplies are low.

  • PDF

The Radioprotective Effect and Mechanism of Captopril on Radiation Induced-Heart Damage in Rats (방사선 조사 후 발생한 흰쥐 심장손상에서 Captopril의 방어역할과 기전)

  • Chang Seung-Hee;Lee Kyung-Ja;Koo Heasoo
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.40-54
    • /
    • 2004
  • Purpose : Captopril (angiotension converting enzyme inhibitor) is known to have a radioproptective effect in the lungs, intestines and skin, but its effect in the heart is unclear. To investigate the radioprotectlve efiect and mechanism of captopril on the heart, the histopathological changes and immunohistochemical stains were compared with radiation alone, and radiation combined with captopril, in the rats. Materials and Methods : The histopathological changes and immunohistochemical stains ($TNF{\alpha}$, $TGF{\beta}1$, PDGF and FGF2) were examined in the radiation alone and the combined captopril and radiation groups, 2 and 8 weeks after irradiation. Each group consisted of 8 to 10 rats (Sprague-Dawley). Irradiation (12.5 Gy) was given to the left hemithorax in a single fraction. Captopril (50 mg/Kg/d) mixed with water, was given orally and continuously from the first week prior to, up to the 8th week of the experiment. Results : In the radiation alone group, the ventricle at 2 weeks after irradiation showed prominent edema (p=0.082) and fibrin deposit (p=0.018) compared to the control group. At 8 weeks, the edema was decreased and fibrosis increased compared to those at 2 weeks. The histopathological changes of the combined group were similar to those of the control group, due to the reduced radiation toxicity at 2 and 8 weeks. The endocardial fibrin deposit (p=0.047) in the atrium, and the interstitial fibrin deposit (p=0.019) and edema (p=0.042) of the ventricle were reduced significantly in the combined group compared to those in the radiation alone group at 2 weeks. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$, PDGF and FGF-2 in the radiation alone group were more increased than in the control group, especially in the pericardium and endocardium of the atrium at 2 weeks. At 8 weeks, the pericardial $TNF-{\alpha}$ and $TGF-{\beta}1$ in the radiation alone group continuously increased. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$ and PDGF were decreased in the combined group at 2 weeks. At 8 weeks, the expressions of $TNF-{\alpha}$ in the atrial and ventricular pericardia were markedly reduced (p=0.049, p=0.009). Conclusion : This study revealed that the early heart damage induced by radiation can be reduced by the addition of captopril in a rat model. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$ and PDGF were further decreased in the combined compared to the radiation alone group at both 2 and 8 weeks. From these results, it may be concluded that these cytokines probably play roles in the radioprotective mechanism of captopril from the radiation-induced heart toxicity, similarly to in other organs.

The Effect of External Radiation Therapy in Management of Malignant Obstructive Jaundice due to Porta Hepatis Metastasis from Stomach Cancer (위암의 간문맥 전이로 발생한 악성 폐쇄성 황달에 대한 외부 방사선치료 효과)

  • Yang, Kwang-Mo;Kim, Joon-Hee;Kim, Chul-Soo;Suh, Hyun-Suk;Kim, Re-Hwe
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.339-348
    • /
    • 1995
  • Purpose : Since 1983, authors have conducted a study to evaluate the effect of external radiation therapy and to determine affected factors in management of the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. Materials and Methods : Thirty two patients with malignant obstructive jaundice due to porta hepatis metastasis from gastric cancer were presented. We have analysed 23 patients who were treated with external radiation therapy of more than 3000cGy. The radiation dose, disease extent at developement of jaundice, total bilirubin levels before radiation therapy, differentiation of histology, combind treatment, intent of primary surgery, initial stage of gastric cancer were analyzed to determine affected factors in radiation therapy. External radiation therapy was delivered with a daily dose of 180-300cGy, 5 times a week fractionation using 4 MeV linear accelerator. The radiation field included the porta hepatis with tumor mass by the abdominal ultrasonography or CT scan. In twenty three patients received more than 3000cGy, total irradiation dose was ranged from 3000cGy to 5480cGy, median 3770cGy. Among 23 patients, 13 patients were delivered more than equivalant dose of TDF 65(4140cGy/23fx). Results : Among 23 patients, complete, partial and no response were observed in 13, 5, 5 patients, respectively. The median survival for all patients was 5 momths. The significant prolongation of median survival was observed in complete responders(11 months) as compared to partial and no responders(5 months, 5 months respectively) Out of 13 patients with complete response, 6 patients lived more than a year Among 13 patients receiving more than 4140cGy equivalent dose, complete, partial and no response were observed in 10, 2 and 1 patients, respectively. The median survival for all these patients was 9.5 months. The median survival for complete responders(10/13) was 11.5 months. Among 10 patients receiving less than 4140cGy equivalent dose, complete, partial and no response were observed in 3, 3, 4 patients, respetively. The median survival for all these patients was 4.3 months Therefore, the radiation dose affected the results of treatment. For the complete response with prolongation of survival duration, at least 4140cGy equivalant dose should be delivered to porta hepatis. In evaluation of the disease extent, 7 patients of 13 complete responders showed localized disease in porta hepatis or peripancreatic area, but all patients with partial and no response showed wide extensive disease or persistant disease of primary gastric cancer. Therefore. the patients with the localized disease were the higher probability of complete response and long term survival. This study suggested that the radiation dose and the disease extent at developement of jaundice affected in radiation therapy for malignant obstructive jaundice. There were no serious complications related to external radiation therapy. Conclusion : External radiation therapy only could achieve the palliative effect in the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. This study suggested that the prolongation of survival duration could be achived in complete responders and radiation dose, extent of disease affected the results of treatment of malignant obstructive jaundice.

  • PDF

Results of Hyperfractionated Radiation Therapy in Bulky Stage Ib, IIa, and IIb Uterine Cervical Cancer (종괴가 큰 병기 Ib, IIa, IIb 자궁경부암에서 다분할 방사선치료의 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.349-356
    • /
    • 1997
  • Purpose : To evaluate the efficacy of hyperfractionated radiation therapy in carcinoma of the cervix, especially on huge exophytic and endophytic stage Ib, IIa and IIb Materials and Materials : Fourty one patients with carcinoma of the cervix treated with hyperfractionated radiation therapy at the Department of Therapeutic Radiology, Dongsan Hospital, Keimyung University. School of Medicine from Jul, 1991 to Apr, 1994. According to FIGO s1aging system, therewere stage Ib (3 patients) IIa (6 patients) with exophytic ($\geq$5cm in dinmeter) and huge endophytic mass. and IIb (32 patients) with median age of 55 yeavs old. Radiation therapy consisted of hyperfractionated external irradition to the whole pelvis (120cGy/fraction, 2 fraction/day (minimum interval of 6 hours), 3600-5520cGy) and boost parametrial doses (for a total of 4480-6480cGy) with midline shield $(4\times10cm)$, and combined with intracavitary irradiation (up to 7480-8520cGy in Ib, IIa and 8480-9980cGy in IIb to point A). The maximum and mean follow up durations were 70 and 47 months respectively . Results : Five year local control rate was $78\%$ and the actuarial overall five year survival rate was $66.1\%$ for all patients, $44.4\%$ for stage Ib, IIa and $71.4\%$ for stage IIb. In bulky IIb (above 5cm in tumor size, 11 patients) five year local control rate and five rear survival rate was $88.9\%,\;73\%$ respectively Pelvic lymph node status (negative : $74\%,\;positive:25\%$, p=0.0015) was significant Prognostic factor affecting to five rear survival rate. There was marginally significant survival difference by total dose to A point ($>84Gy\;:\;70\%,\;>84Gy\;:\;42.8\%$, p=0.1). We consider that the difference of total dose to A point by stage (mean Ib,IIa : 79Gy. IIb 89Gy P=0.001) is one of the causes in worse local control and survival of Ib,IIa than IIb The overall recurrence rate was $39\%$ (16/41). The rates of local failure alone. distant failure alone. and combined local and distant failure were $9.7\%,\;19.5\%,\;and\;9.7\%$, respectively. Two Patients developed leukopenia ($\geq$ grade 3) and Three patients develoued grade 3 gastrointestinal complication. Above grade 3 complication was not noted. There was no treatment related death noted. Conclusion : We thought that it may be necessary to increase A point dose to more than 85Gy in hyperfractionated radiotherapy of huge exophytic and endophvtic stage Ib,IIa. We considered that hyperfractionated radiation therapy may be tolerable in huge exophytic and endophytic stage IIb cervical carcinoma with acceptable morbidity and possible survival gain but this was results in small patient group and will be confirmed by long term follow up in many patients.

  • PDF

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF