• 제목/요약/키워드: Tube-by-tube method

검색결과 1,970건 처리시간 0.025초

Charcoal Tube에 의(依)한 작업환경중(作業環境中) Toluene 함량(含量)에 관(關)한 연구(硏究) (Toluene Determination in Workplace by Charcoal Tube Method)

  • 김형석;구도서;박양원;이정환
    • Journal of Preventive Medicine and Public Health
    • /
    • 제16권1호
    • /
    • pp.193-198
    • /
    • 1983
  • In the determination of organic solvents in workplaces direct reading tube method have been used in Korea for decades. But this method is less accurate and couldn't measure TWA(Time Weighted Average) for 8 hours. Authors tried to detect Toluene concentration in S factory by using charcoal tube according to NIOSH method. The concentration was 158.8ppm. We propose this charcoal tube method should be substituted to get accurate results and to protect employee in workplaces related with solvents.

  • PDF

강관구속 고강도 철근콘크리트 기둥의 내진성능 (Seismic Performance of High-Stringth RC Short Columns Confined in Rectangular Steel Tube)

  • 한병찬
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.182-190
    • /
    • 1997
  • A new method to prevent reinforced concrete columns from brittle failure. The method is called transversely reinforcing method in which only the critical regions are confined in steel tube. The steel tubes can change the failure mode of the latter columns from the shear to the flexure. The steel tubes also increase the compressive strength, shear strength and deformation capacity of the infilled concrete. The following conclusions are reached on bases of the study on the seismic performance of the high-strength RC rectangualr short columns confined in steel tube with shear span tho depth ratio of 2.0 The brittle shear failure of high-strength reinforced concrete short columns with large amount of longitudinal bars, which cannot prevented by using the maximum amount of welded hoops, can be prevented by using the steel tube which confines all the maximum amount of welded hoops, can be prevented by using the steel tube which confines all the concrete inclusive of cover concrete. High-strength RC short columns confined in rectangular steel tube provided excellent enhancement of seismic performance but, found that plastic buckling of the steel tube in the hinge regions tended to occur when the columns were subjected to large cyclic lateral displacements. In order to prevent the plastic buckling when the columns lies on large on cyclic lateral displacements, the steel ribs were used for columns. Tests have established that the columns provide excellent enhancement of seismic performance of inadequately confined columns.

  • PDF

역공학과 해석적 방법을 이용한 관재벌지시험에서의 관재물성치 결정 (Determination of Material Properties of Tube using Inverse Engineering and Analytic Method in Tube Bulge Test)

  • 김태준;김낙수
    • 대한기계학회논문집A
    • /
    • 제27권9호
    • /
    • pp.1508-1516
    • /
    • 2003
  • In numerical analysis for hydroforming process, the stress calculation is effected by flow stress which is general obtained by stress-strain relationship from uni-axial tension test, so the result of the analysis, especially in tube hydroforming, has limitation of accuracy, tubes are made in roll-forming process and become work-hardened. Then roll forming process causes material properties between rolling direction and circumstantial direction of the tube to be different. So it is difficult to predict material behavior in the process condition of bi-axial stress state. In this study, the flow stress of the tube is determined by inverse engineering approach and bulge test that is widely used for formability test in the condition of bi-axial stress. And Hill's quadratic yield function and flow rule are used to consider the anisotropy of the tube in the roll forming process.

C-arm 각도 변화에 따른 피폭선량 비교 (Comparison of Exposure dose according to the C-arm Angle Change)

  • 신성규
    • 한국콘텐츠학회논문지
    • /
    • 제11권9호
    • /
    • pp.453-458
    • /
    • 2011
  • 본 연구는 C-arm의 각도 변화에 따라 술자의 피폭선량의 변화를 알아보고자 시행 하였다. 실험방법은 101kvp, 4.9mA로 고정하고 조사시간을 3초와 5초로 나누어 시행 하였으며 C-arm Tube를 under와 over로 위치시켜 각각 -30도에서 0, 30, 60, 90도로 변화를 주어 5회 측정하여 평균값을 구하였다. 검출기는 C-arm을 조작하는 방사선사의 위치에서 지면으로부터 160cm의 높이에서 측정하였다. 결과는 -30도에서 측정치가 가장 높았고 0, 30, 60, 90도 순으로 낮았으며 under보다 over tube 방식에서 높았다. 그러므로 방사선사의 피폭선량 저감을 위해서는 over tube 방식보다는 under tube 방식을 사용하고 각도에 변화를 줄 때에는 tube가 술자로부터 멀어지는 각도를 사용하고 가능하다면 조사시간을 단축하는 것이 같은 영상을 만들 수 있으면서도 피폭을 줄일 수 있는 방안이다.

경계요소법을 이용한 축대칭 소음기의 성능해석 (Performance Analysis of Axisymmetric Mufflers by BEM)

  • 권영필;임정빈;정갑철
    • 소음진동
    • /
    • 제5권3호
    • /
    • pp.337-344
    • /
    • 1995
  • A BEM program is developed for the performance analysis of axisymmetric mufflers. In the program the sub-region method is used to deal with singularity or inner boundary. The program is applied to typical axisymmjetric mufflers such as simple expansion, extended tube, perforated tube and absorptive expansion sufflers. The transmission losses of the mufflers are calculated by the program and compared with experiments. It is found that the prediction is in a good agreement with measurement, except for the absorptive muffler with parallel lining.

  • PDF

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

Convection Effects on PGSE-NMR Self-Diffusion Measurements at Low Temperature: Investigation into Sources of Induced Convective Flows

  • Chung, Kee-Choo;Yu, Hyo-Yeon;Ahn, Sang-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.1970-1974
    • /
    • 2011
  • The effects of convection on the measurement of the diffusion coefficients of liquids by the pulsed gradient spin echo (PGSE) NMR method at low temperature are discussed. To examine the generation of convective flows, we used four different types of sample tubes in the diffusion measurements with temperature variation; a normal 5 mm NMR tube, a Shigemi tube, an ELISE type tube, and a capillary tube. Below room temperature, the calculated diffusion coefficients of chloroform in 5 mm o.d. type tubes increased with decreasing temperature, while those in the capillary tube decreased linearly. The convective flow was found to be significant even at low temperature and it seemed to be mainly induced by the transverse temperature gradient. It was also found that the capillary tube was most appropriate to measure the diffusion coefficients, since its small diameter is effective in suppressing the convective flows at both high and low temperatures.

자동차용 플라스틱 연료튜브의 환경온도에 따른 후변형에 관한 연구 (A Study on the Post Deformation According to an Environmental Temperature of the Plastic Fuel Tube for Automobile)

  • 박정식;문찬용;정영득
    • 동력기계공학회지
    • /
    • 제7권2호
    • /
    • pp.56-60
    • /
    • 2003
  • Recently the plastic fuel tube is usually used to reduce production cost and weight in automobiles. These days, material used to plastic fuel tube is the polyamide12. The fuel tube is made of the PA12. Post deformation of the tube has been changed by environmental temperature. So, it is important to prevent post deformation. The experiment is performed to investigate post deformation of the tube produced by each bending process. In this study, the results we obtained are used to bending process system for post deformation as the environmental temperature of the tube. It turned out that the method of steam heating and air cooling was shown less deformation than other methods.

  • PDF

중수로 기기냉각수 열교환기 내부 유동 해석 (Analysis of Internal Flow for Component Cooling Water Heat Exchanger in CANDU Nuclear Power Plants)

  • 송석윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.33-41
    • /
    • 2012
  • The component cooling water heat exchangers are critical components in a nuclear power plant. As the operation years of the heat exchanger go by, the maintenance costs required for continuous operation also increase. Most heat exchangers have carbon steel shells, tube support plates and flow baffles. The titanium tube is susceptible to flow induced vibration. The damage on carbon steel tube support rod and titanium tube around cooling water entrance area is inevitable. Therefore, analysis of internal flow around the component cooling water entrance and tube channel is a good opportunity to seek for failure prevention practice and maintenance method. The numerical study was carried out by FLUENT code to find out the causes of tube failure and its location.

화력발전 보일러 과열기 및 재열기 운전 중 튜브 온도예측기법 (Temperature Prediction Method for Superheater and Reheater Tubes of Fossil Power Plant Boiler During Operation)

  • 김범신;송기욱;유성연
    • 대한기계학회논문집A
    • /
    • 제36권5호
    • /
    • pp.563-569
    • /
    • 2012
  • 대용량 화력발전 보일러 과열기와 재열기 튜브는 과열에 취약하여 보일러 정지 시 튜브 내부의 산화 스케일 두께를 측정하여 과열상태를 평가한다. 산화스케일 두께측정에 의한 튜브 온도예측은 튜브의 발췌가 불가피하고 정확한 과열지점의 선정과 튜브의 초기운전온도가 확보되지 못하면 유의한 튜브온도예측결과를 얻을 수 없는 문제점이 있다. 또한 해석적 방법에 의해 튜브 온도를 예측하는 경우 튜브 외부 연소가스에 대한 연소, 복사, 대류 및 난류유동에 대한 방대한 해석이 필요한 반면 순시적인 부하의 변동, 탄종의 변화 및 운전방법의 변화를 반영할 수 없으므로 지속적인 튜브의 온도를 예측할 수 없는 단점이 있다. 본 논문에서는 보일러 운전정보와 유로망 해석을 통해 튜브의 열유속을 계산하고 이를 이용하여 단시간에 튜브의 온도를 예측할 수 있는 기법을 제시하였다. 본 기법을 Larson-Miller Parameter 법과 같은 실용적인 튜브 손상평가기법과 결합하면 유용한 고온손상감시의 수단으로 활용이 가능할 것으로 판단된다.