• Title/Summary/Keyword: Tube-by-tube method

Search Result 1,987, Processing Time 0.033 seconds

Bending Performance Evaluation of Concrete Filled Tubular Structures With Various Diameter-thickness Ratios and Concrete Strengths (콘크리트 충전강관 구조의 직경-두께비 및 콘크리트 강도 변화에 따른 휨 성능 평가)

  • Lee, Sang-Youl;Park, Dae-Yong;Lee, Sang-Bum;Lee, Rae-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.223-230
    • /
    • 2009
  • In this study we deal with bending behaviors of a concrete filled tubular(CFT) with various diameter-thickness ratios and concrete strengths. In finite element analysis using a commercial package(LUSAS), the bonding effect between concrete and steel in CFT structures is modeled by applying a joint element for the bonding surface. In order to consider the nonlinearity of concrete and steel tubes, stress-strain curves of the concrete and steel are used for the increased stresses in a plastic domain. The numerical results obtained from the proposed method show good agreement with the experimental data from load-displacement curves of a steel tube under distributed loads. Several parametric studies are focused on structural characteristics of CFT under bending effects for different diameter-thickness ratios and concrete strengths.

Three-dimensional CFD simulation of geyser boiling in high-temperature sodium heat pipe

  • Dahai Wang;Yugao Ma;Fangjun Hong
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2029-2038
    • /
    • 2024
  • A deep understanding of the characteristics and mechanism of geyser boiling and capillary pumping is necessary to optimize a high-temperature sodium heat pipe. In this work, the Volume of Fluid (VOF) two-phase model and the capillary force model in the mesh wick were used to model the complex phase change and fluid flow in the heat pipe. Computational Fluid Dynamics (CFD) simulations successfully predicted the process of bubble nucleation, growth, aggregation, and detachment from the wall in the liquid pool of the evaporation section of the heat pipe in horizontal and tilted states, as well as the reflux phenomenon of capillary suction within the wick. The accuracy and stability of the capillary force model within the wick were verified. In addition, the causes of geyser boiling in heat pipes were analyzed by extracting the oscillation distribution of heat pipe wall temperature. The results show that adding the capillary force model within the wick structure can reasonably simulate the liquid backflow phenomenon at the condensation; Under the horizontal and inclined operating conditions of the heat pipe, the phenomenon of local dry-out will occur, resulting in a sharp increase in local temperature. The speed of bubble detachment and the timely reflux of liquid sodium (condensate) replenishment in the wick play a vital role in the geyser temperature oscillation of the tube wall. The numerical simulation method and the results of this study are anticipated to provide a good reference for the investigation of geyser boiling in high-temperature heat pipes.

Solvothermal Synthesis and Characterization of Cu3(BTC)2 Tubular Membranes Using Surface Modified Supports (표면 개질된 지지체를 이용한 Cu3(BTC)2 튜브형 분리막의 용매열 합성 및 특성분석)

  • Noh, Seung-Jun;Kim, Jinsoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.214-218
    • /
    • 2014
  • In this study, nanoporous $Cu_3(BTC)_2$ membranes were synthesized on macroporous alumina tube supports by solvothermal method. It is very difficult to prepare uniform and crack-free $Cu_3(BTC)_2$ layer on macroporous alumina support by in situ solvothermal method. In this study, continuous and crack-free $Cu_3(BTC)_2$ tubular membranes could be obtained by in situ solvothermal process after surface modification of alumina support. The surface modification was conducted by spraying Cu precursor solution on the alumina support heated at $200^{\circ}C$. The prepared $Cu_3(BTC)_2$ tubular membranes were characterized by XRD, FE-SEM and gas permeation experiments. $H_2$ permeance through $5{\mu}m$ thick $Cu_3(BTC)_2$ tubular membrane was calculated to be $7.8{\times}10^{-7}mol/s{\cdot}m^2{\cdot}Pa$ by single gas permeation test, with the ideal selectivities of $H_2/N_2=11.94$, and $H_2/CO_2=12.82$.

Simultaneous Determination of Octylphenol, Nonylphenol and Bis(2-ethylhexyl)phthalate in Fish Samples Using Two Internal Standards (2가지 내부표준물질을 이용하여 어류시료 중 Octylphenol, Nonylphenol, Bis(2-ethylhexyl)phehalate의 동시정량)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.244-252
    • /
    • 2001
  • A comprehensive analytical method of endocrine distruptors[i.e., nonylphenol(NP), octylphenol(OP), bis(2-ethylhexyl)phthalate(BEHP)] is fish samples was developed using two internal standards. This method employed closed culture tube extraction with dichloromethane and solvent exchange to iso-hexane and SPE(2g) aminopropyl column, followed by determination on gas chromatograph linked to mass spectrometer(GC/MS) operated in the single ion monitoring(SIM) mode. The recoveries of nonylphenol and octyphenol in the range of $0.2{\sim}20{\mu}g/g$ using 1-phenyl decanol as one internal standard were over 75%, and recovery of bis(2-ethylhexyl)phthalate in the range of $0.4{\sim}40{\mu}g/g$ using bis(2-ethylbutyl)phthalate(BEBP) as the other internal standards was showed over 102%. The present method was applied to fish samples from Korea and UK. The range of concentrations for nonylphnol(NP) and bis(2-ethylhexyl)phthalate in Korean fish were $0.02{\sim}0.06{\mu}g/g$ in 2 samples and $0.18{\sim}2.03{\mu}g/g$ in 9 samples respectively, but bis(2-ethylhexyl)phthalate(BEHP) in UK samples was found $2.99{\mu}g/g$ in just 1 sample. But octylphenol(OP) was not dected in any samples by this method. This two internal standard method provides a more precise analytical tool to investigate endocrine disruptors in a biological matrices of limited quantity.

  • PDF

A Literature Study on the Korean Acupuncture for the Treatment of Stroke (국내침구서적의 중풍치료에 관한 문헌 연구 - $\ll$치종지남(治腫指南)$gg$$\ll$동의보감(東醫寶鑑)$gg$$\ll$침구경험방(鍼灸經驗方)$gg$$\ll$교감 사암도인침법(校勘 舍岩道人鍼法)$gg$의 비교연구 -)

  • Han, Chang-Hyun;Park, Sang-Young;Ahn, Sang-Young;Kwon, Oh-Min;Ahn, Sang-Woo
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.145-163
    • /
    • 2009
  • Background : Stroke occurrences are prevalent and require intensive care for its treatment and rehabilitation. Acupuncture has been widely used in Korea throughout the history and provides an efficient method in the treatment of it. Objectives : To establish a distinctive and efficient acupuncture method for the treatment of stroke based in literature research. Method : We reviewed four Korean medical literature, $ll$治腫指南Guide to Swollen Sore Treatment$gg$, $ll$東醫寶鑑Treasured Mirror of Eastern Medicine$gg$, $ll$鍼灸經驗方Experiential Prescriptions of Acupuncture and Moxibustion$gg$, and $ll$舍岩鍼法Essential Rhymes on Acupuncture and Moxibustion by Master Sa-am$gg$, and analyzed the therapeutic characteristics in the treatment of stroke. Result : 1. In $ll$治腫指南Guide to Swollen Sore Treatment$gg$, various types of treatment can be found. Besides acupuncture, cupping, moxibustion with moxa tube, and bath therapy using Duchesneae Indicae Herba and Sal was applied. Needling in sublingual and vocal region, and also points like GB20, GB31, LI15, BL60, GV20, GV20, TE4, GB39, LU5, ST36, GB30 were frequently inserted. 2. In $ll$東醫寶鑑Treasured Mirror of Eastern Medicine$gg$, moxibustion treatment were in top priority. Points like GV20, LI15, LI11, GB31, ST36, GB39, LI4, GB20 pertinent to Governor, Conception, Gallbladder, Large Intestine, and Stomach meridian were most frequently needled. Selection of adjacent point was widely applied. 3. $ll$鍼灸經驗方Experiential Prescriptions of Acupuncture and Moxibustion$gg$ has some similarity compared to $ll$東醫寶鑑 Treasured Mirror of Eastern Medicine$gg$ in considering the moxa in top priority. But selected points far from the disease site. Main points were LI4, ST36, GB39, PC5, GV20, LI11, LR3, BL40, HT7. 4. $ll$校勘 舍岩道人鍼法Essential Rhymes on Acupuncture and Moxibustion by Master Sa-am$gg$ having the same content orders with $ll$鍼灸經驗方Experiential Prescriptions of Acupuncture and Moxibustion$gg$, it may had some influence from it. But the differences are also apparent. It emphasized in using mother-supplementing child-draining method, experiential prescriptions and visceral pattern identification. Conclusions : We could find various efficient methods through literature research of medical classics. This will not be limited in stroke alone but also will be applied in other diseases. This study will concurrently result in establishing distinctive therapeutic method characteristic of Korea.

  • PDF

MF sampler: Sampling method for improving the performance of a video based fashion retrieval model (MF sampler: 동영상 기반 패션 검색 모델의 성능 향상을 위한 샘플링 방법)

  • Baek, Sanghun;Park, Jonghyuk
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.4
    • /
    • pp.329-346
    • /
    • 2022
  • Recently, as the market for short form videos (Instagram, TikTok, YouTube) on social media has gradually increased, research using them is actively being conducted in the artificial intelligence field. A representative research field is Video to Shop, which detects fashion products in videos and searches for product images. In such a video-based artificial intelligence model, product features are extracted using convolution operations. However, due to the limitation of computational resources, extracting features using all the frames in the video is practically impossible. For this reason, existing studies have improved the model's performance by sampling only a part of the entire frame or developing a sampling method using the subject's characteristics. In the existing Video to Shop study, when sampling frames, some frames are randomly sampled or sampled at even intervals. However, this sampling method degrades the performance of the fashion product search model while sampling noise frames where the product does not exist. Therefore, this paper proposes a sampling method MF (Missing Fashion items on frame) sampler that removes noise frames and improves the performance of the search model. MF sampler has improved the problem of resource limitations by developing a keyframe mechanism. In addition, the performance of the search model is improved through noise frame removal using the noise detection model. As a result of the experiment, it was confirmed that the proposed method improves the model's performance and helps the model training to be effective.

A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste (생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구)

  • Go, Sung Gyoo;Cho, Yong Kun;Lee, Young Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.97-105
    • /
    • 2012
  • This study examined for possibility of the food wastewater incineration treatment method as one of overland treatment method by incineration through liquefied spray of food wastewater when incinerating domestic wastes under operation and for the relationship, etc of air discharge material discharged in incineration, and the results of study are as follow: The food wastewater as one of overland treatment method was analysed 94-96% of moisture contents. Temperature of incinerator outduct during mixed incineration of food wastewater with MSW was average $897^{\circ}C$ and incineration of only MSW was $925^{\circ}C$. Temperature of the mixed incineration of food wastewater was dropped about $28^{\circ}C$ by incineration of only MSW. Concentration of nitrogen oxides(NOx) among air discharge gases was studied by 50ppm, 46ppm when inputting $200{\ell}/hr$, $300{\ell}/hr$ into the incinerator as the quantity of food wastewater. In the mixed incineration of food wastewater, generation speed of scales in the inside of a tubular exhaust gas boiler became rapid and the scale generation quantity became large but the exhaust gas boiler normally operated since scales were removed in cleaning of the tube with a compressive air cleaning facility and there was no opening clogging phenomena in a filter cloth of the filtering dust collector. The overland treatment method, not ocean dumping of food wastewater can be proposed as a technology since mixed incineration of food wastewater with MSW in the existing domestic waste incineration plant is possible, and operation costs of the incineration facility were reduced since use of chemicals such as ammonia and urinary hydrogen ion excretion, etc used in incineration facilities for removing nitrogen oxides(NOx).

Simultaneous analysis of residual glucocorticoids in egg by LC/MS/MS (LC/MS/MS를 이용한 계란 중 잔류 글루코코티코이드의 동시분석)

  • Jang, Mi-Ae;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.326-335
    • /
    • 2009
  • A specific analytical method able to identify and quantify traces of six glucocorticoids residues in eggs were developed. The extraction and clean-up parameters for simultaneous analysis were evaluated and HPLC and spectrometric conditions were also established. For determination of glucocorticoids, 5 g of egg was transferred into a test tube, adjusted pH 5.2 with acetate buffer and was $\beta$-glucuronidase/arylsulfatase from Helix pomatia added. The mixture was centrifuged and supernatant was extracted twice with 20 mL n-hexane. The extraction was performed with HLB cartridge using methanol, followed by clean-up with silica cartridge using methanol/ethyl acetate (4/6, v/v). The analytes were determined by HPLC/ESI-MS/MS operating in the negative ion mode. Validation studies with fortified egg samples for established method were performed. The result of method validation gave good efficiency, linearity, accuracy and precision. The correlation coefficients ($r^2$) of the calibration curves appeared to be higher than 0.99 in egg, indicating excellent linearity. LOD was ranged 0.09 to $0.17{\mu}g/kg$, and recoveries for most compounds were in the range of 55.7-69.8%. This method can be used to determine ${\mu}g/kg$ levels of glucocorticoids in eggs.

A Suggestion for Counting Efficiency Management of the Automation Instrument (자동화장비 계측효율 관리적 측정방법 제안)

  • Park, Jun Mo;Kim, Han Chul;Choi, Seung Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2018
  • Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.

Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment (진단용엑스선촬영장치의 간접 선량 계산법 개발)

  • Kim, Jung-Su;Kim, Sung-Hwan;Jeon, Min-Cheol;Ju, Won-Ha;Jeong, Min-Gyu;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.