• Title/Summary/Keyword: Tube Current

Search Result 926, Processing Time 0.03 seconds

MRPC eddy current flaw classification in tubes using deep neural networks

  • Park, Jinhyun;Han, Seong-Jin;Munir, Nauman;Yeom, Yun-Taek;Song, Sung-Jin;Kim, Hak-Joon;Kwon, Se-Gon
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1784-1790
    • /
    • 2019
  • Accurate and consistent characterization of defects in steam generator tubes (SGT) in nuclear power plants is one of the key issues in the field of nondestructive testing since the large number of signals to be analyzed in a time-limited in-service inspection causes a serious problem in practice. This paper presents an effective approach to this difficult task of automated classification of motorized rotating pancake coil (MRPC) eddy current flaw acquired from tube specimens with deliberated defects using deep neural networks (DNN). This approach consists of five steps, namely, the data acquisition using the MRPC probe in the tube, the signal preprocessing to make data more suitable for training DNN, the data augmentation for boosting a training performance, the training of DNN, and finally demonstration of the trained DNN for discriminating the axial and circumferential defects. The high performance obtained in this study shows that DNN is useful for classification of defects in tubes from the MRPC eddy current signals even though the number of signals is very large.

Computation of the Current Limiting Behavior of BSCCO-2212 High-Temperature Superconducting Tube with Shunt Coils

  • Kim, H.M.;Park, K.B.;Lee, B.W.;Oh, I.;Sim, J.;Hyun, O.B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.4
    • /
    • pp.22-25
    • /
    • 2006
  • This paper deals with the computation of the current limiting behavior of high-temperature superconducting (HTS) modules for the superconducting fault current limiter (SFCL). The SFCL module consists of a monofilar type BSCCO-2212 tube and a shunt coil made of copper or brass. The shunt coil is connected to the monofilar superconducting tube in parallel. Through analysis of the quench behavior of the monofilar component with shunt coils, it is achieved to drive an equivalent circuit equation from the experimental circuit structure. In order to analyze the quench behavior of the SFCL module, we derived a partial differential equation technique. Inductance of the monofilar component and the impedance of the shunt coil are calculated by Bio-Savart and Ohm's formula, respectively. We computed the quench behavior using the calculated values, and compared the results with experimental results for the quench characteristics of a component. The results of computation and test agreed well each other, and it was concluded that the analytic result could be applied effectively to design of the distribution-level SFCL system.

Fiber-Optic Michelson Interferometric AC Current Sensor (광섬유 마이켈슨 간섭계형 교류 전류센서)

  • Kim, Chang-Won;Park, Dong-Su;Kim, Myung-Gyoo;Lee, Jung-Hee;Kang, Shin-Won;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.22-28
    • /
    • 1995
  • A Michelson interferometric AC current sensor has been fabricated by using a single mode optical fiber and a cylindrical PZT tube of which a radial dimension varies with applied voltage. The signal processing scheme used in this work, measures the magnitude of AC current regardless of the frequency of the current. An AC current is measured by counting the number of interference fringe during half cycle of the AC current. The number of interference fringes varies linearly with the magnitude of the current and the error range is within 5% at the temperature range from $-20^{\circ}C$ to $80^{\circ}C$.

  • PDF

Do North Korean Social Media Show Signs of Change?: An Examination of a YouTube Channel Using Qualitative Tagging and Social Network Analysis

  • Park, Han Woo;Lim, Yon Soo
    • Journal of Contemporary Eastern Asia
    • /
    • v.19 no.1
    • /
    • pp.123-143
    • /
    • 2020
  • This study examines the interplay between the reactions of YouTube users and North Korean propaganda. Interesting enough, the study has noticed changes in the strict media environment under young leader Kim. Messages delivered by the communist regime to the outside world appeared to resemble those of 'normal' countries. Although North Korean YouTube was led mainly by the account operator, visitors from different nations do comment on the channel, which suggests the possibility of building international communities for propaganda purposes. Overall, the study observed a sparsely connected social network among ordinary commenters. However, the operator did not exercise tight control over peer-to-peer communication but merely answered questions and tried to facilitate mass participation. In contrast to the many news clips, the documentary content on North Korea's YouTube channel did not explicitly advocate for North Korea's current political positions.

Analysis and design of LNG open rack vaporizer (LNG 개방래크 기화기의 해석 및 설계)

  • Park, J.S.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.189-197
    • /
    • 1997
  • The vaporizing characteristics of LNG(liquefied natural gas) via heat exchanger with sea water are analytically studied for an open rack vaporizer(ORV). This study is intended to supply the design data for the domestic fabrication of the corrosion-resistant vaporizer tube. A computational program is developed to predict the exit temperature of LNG for various conditions. In the program, thesimple and justifiable heat transfer models are selected for fully-developed internal flow of LNG, the star-shaped finned-tube, and the external falling films of sea water, as well as the possible ice formation and the fouling on the tube walls. It is found that the enongh corrugation inside of the tube wall is the most significant in the vaporizer performance for the current operating conditions. the effects of other design parameters on the heat exchanger between LNG and sea water are quantitatively presented.

  • PDF

A Study on the Image Effect of Tube Voltage (관전압(管電壓)이 화상(畵像)에 미치는 영향(影響))

  • Kang, Hong-Seok;Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.49-55
    • /
    • 1980
  • To know the effect of tube voltage to X-ray film image, authors made an experimental study on the exponential value of applied voltage and the effect of scattered ray in photographic contrast, and obtained the results as follows: 1. The exponential value of tube voltage was under the control of the applied voltage, the kinds of screens and grids, and its existence. The range of its value was from 1.03 to 5.3. 2. The efficiency of X-ray production was directly proportional to the applied voltage, and to oftain the same density, the tube current(mAs) was inversely proportional to applied voltage 3. The production of scattered rays was in proportion to the tube voltage, and the photographic contrast was mainly influenced by the scattered rays.

  • PDF

Development and its Characteristics of the 40kV x-ray transmission anode target tube (40kV용 투과 양극형 x-ray tube의 개발 및 특성분석)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.234-239
    • /
    • 2008
  • Tungsten and rhodium target tube for a 40 kV x-ray transmission anode was developed to apply to the hand-held XRF(X-Ray Fluorescence) apparatus and its characteristics were evaluated. From the measurement of the energy distribution and dose of x-ray, it was confirmed that our results were good agreements with the known ones. The optimum thickness of metal film deposited on Be window to extract the maximum dose were $2.6{\mu}m$ and $2.7{\mu}m$ in case of W-target tube and Rh-target tube, respectively. When it was continuously worked during 30 min. at 40 kV in tube voltage and at $60{\mu}A$ in tube current, the temperature at target did not exceed $50^{\circ}C$. Our results reveals that the 40 kV x-ray transmission anode tube can be applied to the hand-held XRF apparatus.

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Intercomparisonn of Techniques for Pressure Tube Inspection of Pressurized heavy Water Reactor (가압 중수로형 원자력발전소 압력관 비파괴검사기술의 상호비교)

  • Lee, Hee-Jong;Kim, Yong-Si;Yoon, Byung-Sik;Lee, Young-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.294-303
    • /
    • 2005
  • This paper describes the analysis results of a series f Round-Robin test that was performed to intercompare inspection and diagnosis techniques for characterization of pressure tube f a pressurized heavy water reactor under the Coordinated Research Project(CRP) of IAEA's nuclear Power Programme. For this test, six nations, Korea, Canada, India, Argentina, Rumania, and China that currently have pressurized heavy water reactors under operation involved, and the "KOR-1" pressure tube sample prepared by Korea was used. Two kinds of NDE technique, ultrasonic and eddy current test, were applied for these tests. The "KOR-1" pressure tube sample contains total 12 artificial flaws such as crack-like EDM notches, wear that is similar to the real flaws and can be produced on the pressure tubes during plant operation. Test results showed that seven laboratories from six nations detected all twelve flaws in "KOR-1" specimen by using ultrasonic and eddy current test methods, and ultrasonic test method was more accurate than eddy current test method in flaw detectin and sizing. ID flaws in pressure tube sample were more easily detected and accurately sized than OD flaws.

The structural performance of axially loaded CFST columns under various loading conditions

  • Huang, Fuyun;Yu, Xinmeng;Chen, Baochun
    • Steel and Composite Structures
    • /
    • v.13 no.5
    • /
    • pp.451-471
    • /
    • 2012
  • Concrete filled steel tube (CFST) structures have been used widely in high-rise buildings and bridges due to the efficiency of structurally favourable interaction between the steel tube and the concrete core. In the current design codes only one loading condition in the column members is considered, i.e., the load is applied on the steel tube and concrete core at the same time. However, in engineering practice the tube structures may be subjected to various loading conditions such as loading on the concrete core only, preloading on the steel tube skeleton before filling of concrete core, and so on. In this research, a series of comparative experiments were carried out to study the structural performance of concrete filled circular steel tube columns subject to four concentric loading schemes. Then, a generalized prediction method is developed to evaluate the ultimate load capacity of CFST columns subject to various loading conditions. It is shown that the predictions by the proposed method agree well with test results.