• Title/Summary/Keyword: Tube 방향

Search Result 376, Processing Time 0.032 seconds

Optical system design for stereoscopic video-recorder (비디오 입체영상녹화를 위한 광학계 설계)

  • Hong, Kyung-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.506-509
    • /
    • 2002
  • An optical system for a stereoscopic video recorder is designed with the field of view 42$^{\circ}$ and effective diameter 22 mm. We can use it by attaching it to the front lens of any video camera or camcorder to record a stereoscopic scene. This system is a double Kepler type afocal system to make the image erect and a bi-ocular type to record and display the stereoscopic scene. The optical tube length is folded with several flat mirrors and a beam splitter to be compact. This optical system is composed of 4 groups of lenses and each group serves as a relay lens for minimizing the vignetting effect. Whole field stereoscopic scenes may be captured by perpendicularly polarized alternated recording with a chopper and two perpendicular polarizers, without any loss of light energy. The displayed images may be seen stereoscopically with polarized spectacles and are kinetic because of an afterimage effect.

Observation of Light-Propagation along the Tube of Cold Cathode Fluorescent Lamp (냉음극 형광램프의 광 전파)

  • Cho, Y.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.114-126
    • /
    • 2011
  • The light propagation along a long positive column has been observed in a cold cathode fluorescent lamp. The optical signals are observed with the DC and AC voltage power during lamp operation. The light propagating is observed in the operation with the DC-rippled voltage as well as the AC-voltage. The optical signals propagate from the high voltage side to the ground. These signals show two kinds of features according to the before and after Townsend breakdown. At the dark current before Townsend breakdown, the optical intensity is damped and the propagation velocity is $10^4{\sim}10^5m/s$. At the high current of normal glow after Townsend breakdown, the propagation velocity is 1$10^5{\sim}10^6m/s$ without damping.

The Effects of Diluted Fibrin Glue about Continuous Air Leakage after Lung Surgery (폐수술 후 지속적 공기누출에 희석한 Fibrin Glue의 효과)

  • Choi Chang-Woo;Lee Seong-Jin;Lee Chol-Sae;Lee Kihl-Rho;Lee Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.770-774
    • /
    • 2006
  • Background: Continuous air leakage through chest tube after lung surgery may increase pt's hospital stay and lead to many complications including empyema etc. Chemical pleurodesis has frequently been used for prevention of air leakage. Therefore, we performed chemical pleurodesis using diluted fibrin glue in patients with continuous air leak-age and observed the effects and efficiency of treatment. Material and Method: From September, 2001 to August, 2005, 16 patients whose continuous air leakage lasted more than 7 days underwent chemical pleurodesis with diluted fibrin glue. The effects of treatment, complications and recurrences were reviewed. Dissolved fibrinogen 1.0 g and aprotinin 500,000 KIU were mixed in a 50 cc syringe (Mixed solution A). And dissolved thrombin 5,000 IU and Calcium chloride 600 mg were mixed in a 50 cc syringe (Mixed solution B). Cefazolin 1.0 g was mixed in a 50 cc syringe (Mixed solution C). Rubber tube was inserted between the chest tube and the collecting bottle. An inserted rubber tube was positioned 60cm above the patient and forming a loop appearance was done. Mixed solutions A, B and C were injected into the highest rubber tube. Results: Continuous air leakages disappeared in all f6 patients at next day. Chest tubes were removed after 3 days in all patients. Complications were chest pain in 12 patients (75%), leukocytosis in 14 patients (88%), fever and chill in 14 patients (88%). All complications were transient and disappeared without specific treatment. Conclusion: Our findings demonstrated that diluted fibrin glue chemical pleurodesis was effective in patients with continuous air leakage lasting more than 7 days. Diluted fibrin glue chemical pleurodesis had good results with acceptable complications. long term follow-up is necessary to evaluate the accurate effects of treatment and recurrence in a large number of patients.

Photoluminescence Characteristics of ZnO Nanowires Grown on a-, c- and m-plane Oriented 4H-SiC Substrates (4H-SiC 기판의 a-, c-, m-면방향에 따른 ZnO 나노선의 Photoluminescence 특성 분석)

  • Kim, Ik-Ju;Yer, In-Hyung;Moon, Byung-Moo;Kang, Min-Seok;Koo, Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.349-352
    • /
    • 2012
  • ZnO thin films were deposited on a-, c- and m- plane oriented 4H-SiC substrates by pulsed laser deposition. ZnO nanowires were formed on substrates by tube furnace. Shape and density of the ZnO nanowires were investigated by field emission scanning electron microscope. Average surface roughness and root mean square surface roughness were measure by atomic force microscope. Optical properties were investigated by Photoluminescence measurement. Density of ZnO nanowires grown on a-, c- and m-plane oriented 4H-SiC substrates were 17.89 ${\mu}m^{-2}$, 9.98 ${\mu}m^{-2}$ and 2.61 ${\mu}m^{-2}$, respectively.

CO Gas Sensing Characteristic of ZnO Nanowires Based on the a-, cand m-plane Oriented 4H-SiC Substrate at 300℃ (a-, c-, m-면방향의 4H-SiC 기판에 형성된 ZnO 나노선 가스센서의 300℃에서 CO 가스 감지 특성)

  • Jeong, Gyeong-Hwan;Lee, Jung-Ho;Kang, Min-Seok;Koo, Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.441-445
    • /
    • 2013
  • ZnO nanowires on the a-, c- and m-plane oriented 4H-SiC substrates were grown by using a high temperature tube furnace. Ti/Au electrodes were deposited on ZnO nanowires and a-, c- and m-plane 4H-SiC substrates, respectively. The shape and density of the ZnO nanowires were investigated by field emission scanning electron microscope. It was found that the growth direction of nanowires depends strongly on growth parameters such as growth temperature and pressure. In this work, The sensitivity of nanowires formed a-, c- and m-plane oriented 4H-SiC gas sensor was measured at $300^{\circ}C$ with CO gas concentration of 80%. The nanowires grown on a-plane oriented 4H-SiC show improved sensing performance than those on c- and m-plane oriented 4H-SiC due to the increased density of nanowire on a-plane 4H-SiC.

Investigation of Cell Size Effects of Honeycomb Sandwich Composite Square Tubes Under Compressive Loadings (허니콤 샌드위치 복합소재 정사각 튜브의 셀 크기에 따른 압축거동평가)

  • Kim, Jung-Seok;Yoon, Hyuk-Jin;Kwon, Tae-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • The objective of this study is to evaluate effects of honeycomb cell size for compressive behaviors of square sandwich composite tubes with woven fabric carbon/epoxy skin and Al honeycomb core. In order to achieve these goals, four different kinds of tubes were fabricated and compressed to 200mm~250mm under quasi-static load of 10mm/min. The Al honeycombs with cell size of 6.35mm and 9.53mm were used. The relationship of mean compressive load and cell size was evaluated. In addition, the effect of peel strength and equivalent elastic modulus in ribbon direction for the mean compressive load was investigated.

Experimental Study of Thermal Performance of Heat Pipe with Axial Trapezoidal Grooves (축방향 사다리꼴 그루브 히트파이프의 열성능에 대한 실험적 연구)

  • Suh, Jeong-Se;Lee, Woon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.407-414
    • /
    • 2003
  • Analysis and experiment are performed to investigate the thermal performance of a heat pipe with axial grooves. The heat pipe was designed in a 6.5 mm I.D., 17 axial trapezoidal grooves. 1000 mm long tube of aluminium, and ammonia as working fluid. A mathematical equations fur heat pipe with axial grooves is formulated to obtain the capillary limitation on heat transport rate in a steady state. As a result, heat transport factor of heat pipe has the maximum at the operating temperature of 293K in 0m elevation. As the elevation of heat pipe increases. the heat transport factor of the heat pipe is reduced markedly, comparing with that of horizontal elevation of the heat pipe. It may be considered that such behavior of heat pipe is caused by the working fluid swarmed back to the condenser port due to gravity force and supercooled by a coolant of heat exchanger. Analytical results of heat transport factor are in a good agreement with those of experiment.

Effects of Flow Diretion and Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Two-Phase Flow(I) - In Case of Upward Flow - (수직이상유에서 유동방향과 동심원관 간극이 유동양식과 보이드분포에 미치는 영향 (I))

  • 손병진;김인석;김문철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.5
    • /
    • pp.856-866
    • /
    • 1987
  • In the present paper a statistical method using probability density function has been applied to investigate experimentally the flow patterns and fluctuations of time-averaged local void fraction in air-water two-phase mixtures which flow vertically upwards in concentric annuli. This study was carried out using three vertical concentric annuli. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel inner rod. The rod diameter is either 12mm, 16mm or 20mm. The two-phase flow patterns observed in the experiment were bubbly, slug, annular and each transition patterns. It was first demonstrated that the variance, coefficients of skewness and kurtosis calculated from probability density function on time-averaged local void fraction can be used to identify the flow patterns in the annular passage, and the fluctuation of time-averaged local void fraction varies with the radial position in annular gap and the flow pattern.

Effects of Wake-Passing Orientation and Frequency on Unsteady Boundary Layer Transition on an Airfoil (주기적 통과 후류의 방향과 주파수가 익형 위 비정상 천이경계층에 미치는 영향)

  • Gang, Sin-Hyeong;Park, Tae-Chun;Jeon, U-Pyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.685-694
    • /
    • 2002
  • Effects of wake-passing orientation and frequency on the wake-induced boundary layer transition on a NACA0012 airfoil are investigated. The wakes are generated by rotating cylinders clockwise (CW) and counterclockwise (CCW) around the airfoil. Time- and phase-averaged streamwise mean velocities and turbulent fluctuations are measured with a single hot-wire probe. Wall skin frictions are estimated by the Computational Preston Tube Method (CPM). The pressure distribution on the airfoil is different according to the wake-passing orientation and frequency. Turbulent patches are generated in the laminar boundary layer due to the passing wake and the boundary layer becomes temporarily transitional. The transition process is significantly affected by the pressure gradient and the turbulent patches. For the receding wake, the turbulent patches propagate more rapidly than those for the approaching wake because adverse pressure gradient becomes larger. As the frequency increases, onset location of transition moles upstream and the boundary layer near the trailing edge becomes more transitional.

A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis (혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구)

  • 김희원;이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.329-336
    • /
    • 2003
  • Intra-Vascular Ultra-Sound (IVUS) transducers were developed for the application to diagnose coronary diseases. The transducer consists of 32 piezoelectric elements with a front insulation layer and a polymeric acoustic backing layer on a hollow alumina tube. The optimal geometrical structure of the transducer was designed through theoretical analysis of radiation patterns of the transducer. Samples of the IVUS transducers of the diameter of 3㎜ were fabricated to illustrate the design scheme. For the piezoelectric elements, 2-2 mode piezocomposite materials were employed. Experimental performance of the transducers showed good agreement with the design results, which verified feasibility of the transducer for IVUS applications.