• 제목/요약/키워드: Trus

검색결과 47건 처리시간 0.033초

Prostate-specific Antigen Velocity (PSAV) and PSAV per Initial Volume (PSAVD) for Early Detection of Prostate Cancer in Chinese Men

  • Zheng, Xiang-Yi;Zhang, Peng;Xie, Li-Ping;You, Qi-Han;Cai, Bo-Sen;Qin, Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권11호
    • /
    • pp.5529-5533
    • /
    • 2012
  • Aim: To investigate the utility of prostate-specific antigen velocity (PSAV) and PSAV per initial volume (PSAVD) for early detection of prostate cancer (PCa) in Chinese men. Methods: Between January 2009 and June 2012, a total of 193 men (aged 49-84 years, median 67 years) with at least 2 transrectal ultrasonography (TRUS) procedures and concurrent serum PSA measurements underwent prostate biopsy because of suspicion of PCa. The total group were classified into PCa and non-PCa groups, and the variables of the two groups were compared. Univariate and multivariate analyses were used to investigate which variables were predictove. The diagnostic values of PSAV, PSAVD and prostate-specific antigen density (PSAD) were compared using receiver operating characteristic (ROC) analysis. Results: Prostate cancer was diagnosed in 44 (22.8%) of the 193 men. There were significant differences between the groups in last and initial prostate volumes determined by TRUS, initial age, last serum PSA levels, PSAV, PSAD and PSAVD. After adjusting for confounding factors, the odds ratios of PCa across the quartile of PSAVD were 1, 4.06, 10.6, and 18.9 (P for trend <0.001).The area under the ROC curves (AUCs) of PSAD (0.779) and PSAVD (0.776) were similar and both significantly greater than that of PSA (AUC 0.667). PSAVD was a significantly better indicator of PCa than PSAV (AUC 0.736). There was no statistical significant difference between the AUC of PSAV and that of last serum PSA level. The sensitivity and specificity of PSAVD at a cutoff of 0.023ng in participants with last serum PSA levels of 4.0ng/mL-10.0ng was 73.7% and 70.7%, respectively. Conclusions: The results of this study demonstrated PSAVD may be a useful tool in PCa detection, especially in those undergoing previous TRUS examination.

혈액, 초음파 검사 결과를 이용한 전립선이행대용적의 상관관계 연구: 기초질환이 없는 30대를 대상으로 (A Study on the Correlations between Total Prostate Volume and Prostate Transition Zone Volume Assessed Using Blood and Ultrasound Tests: in the Healthy Korean Men in Thirties)

  • 김상현
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.407-412
    • /
    • 2017
  • 본 연구는 혈액 검사 결과인 전립선특이항원(PSA) 및 전립선특이항원밀도 (PSAD), 전립선 경직장 초음파 (TRUS)를 이용한 전립선 전체용적 (TPV), 나이등 변수와 전립선이행대용적 (PTZV)과 상관관계를 연구하여 임상적 지표로 활용하고자 한다. 2007년 6월부터 2016년 4월 까지 전립선에 대한 치료력이 없는 건강한 30대 성인 남성으로 TRUS와 PSA, PSAD 혈액 검사를 실시한 총 68명을 후향적으로 분석하였다. 초음파 장비는 Siemens Acuson sequoia 512)와 탐촉자 Siemens EC~10C5 Endocavitary를 이용하였다. 통계 처리의 경우, SPSS 18.0 각 변수와 표준 편차의 평균을 계산하는 데 사용하고, 피어슨 상관관계 분석을 수행 하였다. 변수들의 기술 통계량은 TPV; $24.27{\pm}6.60$, PTZV; $6.99{\pm}6.60$, PSA; $2.12{\pm}2.76$와 PSAD; $0.281{\pm}0.1$이고. 전립선 이행용적과 변수의 상관 계수는 PSAD; 0.831, TPV; 0.707, 나이; 0.398, 그리고 PSA; 0.118이었다. PSA 및 연령과의 양의 크기의 상관관계지만, PSAD, TPV가 높은 상관관계를 보였다. 따라서, 기저 질환이 없는 30대 남성의 PTZV는 TPV와 PSAD를 통해 예측할 수 있다.

경직장초음파를 이용한 전립선 볼륨측정 시의 위치 연구: 전립선모형 제작과 실험 (Location Studies of Prostate Volume Measurement by using Transrectal Ultrasonography: Experimental Study by Self-Produced Prostate Phantom)

  • 김연민;윤준;변일균;이후민;김형균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.437-442
    • /
    • 2015
  • 전립선의 정확한 볼륨측정은 전립선암과 전립선비대의 진단, 치료 결정 및 예후 판정에 있어서 중요한 역할을 한다. 또한, 전립선암 선별검사에 사용하고 있는 혈청전립선특이항원(serum prostate-specific antigen)은 전립선의 볼륨과 서로 높은 상관관계를 보이기 때문에 이를 평가하기 위해서는 정확한 볼륨을 아는 것이 중요하다. 기존의 전립선 측정법이 다양하게 제시되고 있으나 전립선 모형 별 측정법에 대한 연구는 없었다. 본 연구에서는 다양한 모형의 팬텀을 제작하고 초음파를 이용하여 볼륨을 알아본 후 모형 별 측정위치를 찾아 새로운 측정방법을 제시하고자 한다. 초음파 검사를 통해 특징적인 전립선 모양 6개를 선정하였다. 이를 횡단과 종단영상을 참고하여 전립선 모형 6개를 제작하였다. 최적의 측정위치에서 각각 3회씩 반복측정 후 실제볼륨과 측정볼륨간의 유의성을 알아보기 위하여 Wilcoxon 부호순위 검정을 실시하였다. p값은 0.05이하일 때 유의한 것으로 정하였다. Axial 영상에서 돌출부위를 제외하고 안쪽으로 두고, Longitudinal 영상에서는 base와 apex의 오목한 부분에 측정 점을 놓았을 때 실제 전립선 크기와 일치도가 높았다. 실제볼륨과 측정볼륨간의 유의성은 p값 0.156으로 통계적으로 유의한 차이가 없었다. 전립선 axial 영상에서 전립선 이행대의 돌출이 심할 경우 돌출부위를 배제하고 측정하는 것이 실제 볼륨에 가까웠다. 또한 longitudinal영상에서는 apex부분이 가늘고 길어질 경우에 끝부분이 아닌 안쪽으로 측정 점을 잡아 그 점을 기준으로 타원을 그려 볼륨을 측정하는 것이 실제 볼륨에 가장 가까웠다.

A Study on the Relationship between Properties of the Elliptic Curves and Performance of Elliptic Curve Method (ECM)

  • Jizhe Cui;Shin, Seung-won;Park, Jong-Uk
    • 한국지능정보시스템학회:학술대회논문집
    • /
    • 한국지능정보시스템학회 2000년도 춘계정기학술대회 e-Business를 위한 지능형 정보기술 / 한국지능정보시스템학회
    • /
    • pp.475-478
    • /
    • 2000
  • Recently encryption algorithms based on difficulties of factorization have been used with popularization. Prime number factorizations are progressed rapidly. In this paper, characteristics of elliptic curve are analyzed and generation of elliptic curves suitable for prime number factorization is discussed.

  • PDF

TRUS 영상에서 질감 특징 예측과 경계 분포를 이용한 전립선 경계 분할 (Delineating the Prostate Boundary on TRUS Image Using Predicting the Texture Features and its Boundary Distribution)

  • 박순화;김호용;서영건
    • 디지털콘텐츠학회 논문지
    • /
    • 제17권6호
    • /
    • pp.603-611
    • /
    • 2016
  • 일반적으로 병원의 의사들은 눈으로 전립선 영상을 보고 수동으로 전립선과 배경의 경계를 구분하였다. 그러나 수동으로 자르는 과정은 너무 많은 시간을 소모하고 의사에 따라 다양한 경계가 추출되었다. 이런 문제를 줄이기 위해 자동 추출방식이 필요하게 되었지만, 전립선 경계의 정확한 추출은 작은 잡음이나 옅은 경계로 인하여 상당히 어려운 일이다. 지금까지 SVM, SIFT, 가버 텍스처 필터, 뱀형상 윤곽선 방법, 평균형상모델들과 같은 많은 연구가 진행되었다. 게다가, 2차원뿐만 3차원 영상, CT나 MRI 등에 관한 연구도 진행되었다. 하지만 아직까지 인간 전문가가 가진 경험을 뛰어 넘는 기술은 개발되지 않았으며, 많은 추가적인 연구를 필요로 하고 있다. 이에 본 논문에서는 전립선 영상의 경계의 평균적인 분포와 경계의 질감 특징을 예축하여 경계를 추출하는 방법을 제안한다. 실험 결과, 의사의 추출 방법과 유사한 경계를 얻을 수 있었다.

Efficacy of Using Sequential Primary Circulating Prostate Cell Detection for Initial Prostate Biopsy in Men Suspected of Prostate Cancer

  • Murray, Nigel P;Reyes, Eduardo;Fuentealba, Cynthia;Jacob, Omar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3385-3390
    • /
    • 2016
  • Background: Sequential use of circulating prostate cell (CPC) detection has been reported to potentially decrease the number of unnecessary prostate biopsies in men suspected of prostate cancer. In order to determine the real world effectiveness of the test, we present a prospective study of men referred to two hospitals from primary care physicians, one using CPC detection to determine the necessity of prostate biopsy the other not doing so. Materials and Methods: Men with a suspicion of prostate cancer because of elevated PSA >4.0ng/ml or abnormal DRE were referred to Hospitals A or B. In Hospital A all underwent 12 core TRUS biopsy, in Hospital B only men CPC (+), with mononuclear cells obtained by differential gel centrifugation identified using double immunomarking with anti-PSA and anti-P504S, were recommended to undergo TRUS biopsy. Biopsies were classifed as cancer or no-cancer. Diagnostic yields were calculated, including the number of posible biopsies that could be avoided and the number of clinically significant cancers that would be missed. Results: Totals of 649 men attended Hospital A, and 552 men attended Hospital B; there were no significant differences in age or serum PSA levels. In Hospital A, 228 (35.1%) men had prostate cancer detected, CPC detection had a sensitivity of 80.7%, a specificity of 88.6%, and a negative predictive value of 89.5%. Some 39/44 men CPC negative with a positive biopsy had low grade small volume tumors. In Hospital B, 316 (57.2%) underwent biopsy. There were no significant differences between populations in terms of CPC and biopsy results. The reduction in the number of biopsies was 40%. Conclusions: The use of sequential CPC testing in the real world gives a clear decision structure for patient management and can reduce the number of biopsies considerably.

The Perceived Information Quality in Accounting Information System: Effects on Trust and Risk

  • Kim, Daekil
    • 한국산업정보학회논문지
    • /
    • 제19권4호
    • /
    • pp.119-131
    • /
    • 2014
  • This study discusses the results of an empirical study carried out to illustrate the key issues that need to be addressed to ensure accounting information quality (AIQ). The study also focuses on the factors of trust and risk as they impact the intention to use accounting information from accounting information systems(AIS). The factors that might impact on accounting information quality have been summarized from the existing literature on previous studies in this area. This study proposes a research model for key issues that have an impact on accounting information quality based on the literature. I use the empirical results of this study to discuss the key components of the research model.

Kaiser Truss를 사용한 일방향 슬래브의 휨 거동에 관한 연구 (An Experimental Study on the Flexural Behavior of Slabs Using Kaiser Truss)

  • 김형근;곽노현;류승곤;이희발;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.30-35
    • /
    • 1994
  • In order to investigate on the behavior of one-way slab with Kaiser. Truss, such as flexural strength, failure mode, and ductile capacity, a total of twenty specimens have been tested and compared with the R.C slab without Kaiser Truss. The major variables are Kaiser Truss intervals(30, 40, 60cm), half slab thickness. Test results showed that support interval of half pc slab can be determined by the flexural strength which causes the concrete crack and there are horizontal cracks between upper concrete and half slab in the connection of the specimen with kaiser truss interval 60cm.

  • PDF

Physics analysis of new TRU recycling options using FCM and MOX fueled PWR assemblies

  • Cho, Ye Seul;Hong, Ser Gi
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.689-699
    • /
    • 2020
  • In this work, new multi-recycling options of TRU nuclides using PWR fuel assemblies comprised of MOX and FCM (Fully Ceramic Micro Encapsulated) fuels are suggested and neutronically analyzed. These options do not use a fully recycling of TRU but a partial recycling where TRUs from MOX fuels are recycled while the ones from FCM fuels are not recycled due to their high consumption rate resulted from high burnup. In particular, additional external TRU feed in MOX fuels for each cycle was considered to significantly increase the TRU consumption rate and the finally selected option is to use external TRU and enriched uranium feed as a makeup for the heavy metal consumption in MOX fuels. This hybrid external feeding of TRU and enriched uranium in MOX fuel was shown to be very effective in significantly increasing TRU consumption rate, maintaining long cycle length, and achieving negative void reactivity worth during recycling.

비만과 전립선암의 연관성 분석 (Association between Obesity and Prostate Cancer)

  • 윤창준;문기학;박동춘
    • Journal of Yeungnam Medical Science
    • /
    • 제22권2호
    • /
    • pp.199-210
    • /
    • 2005
  • 전 세계적으로 비만 인구의 급격한 증가와 이로 인한 다양한 만성질환의 증가가 중요한 건강 문제로 대두되고 있으며, 최근 여러 종류의 암들도 비만과 연관성이 있을 것이라는 연구들이 많이 이루어지고 있다. 비만과 암과의 연관성에 대한 정확한 기전은 아직 밝혀지지 않았으나 다양한 스테로이드와 펩타이드 호르몬 그리고 성장인자가 중요한 역할을 할 것으로 생각되어지며, 전립선암 역시 호르몬 의존성의 종양이므로 남성 비만 환자에서의 증가된 혈청 에스트로겐 농도와 교감 신경계의 활성화 등 비만과 관련된 호르몬의 변화는 전립선암과도 상당한 연관이 있을 것으로 추정된다. 그러나, 지금까지의 비만과 전립선암과의 연관성에 대한 임상연구들은 대부분 서구인을 대상으로 시행되었으며 그 결과 또한 서로 상반되게 발표되고 있어 명확한 연관성을 밝히지 못하고 있는 실정이다. 이에 본 저자들은 한국인을 대상으로 비만과 전립선암과의 연관성을 알아보고자 2000년 1월부터 2005년 6월까지 영남대학교 의과대학 부속병원 비뇨기과에서 임상적으로 전립선암이 의심되어 경직장초음파유도하 전립선생검(transrectal ultrasound guided prostate biopsy)을 시행한 286명을 대상으로 환자들의 의무기록을 후향적으로 분석하여, 환자의 나이, 키, 몸무게, BMI, PSA, DRE, TRUS, 경직장초음파유도하 전립선생검, Gleason 점수, 임상적 병기 등을 비교, 분석하였다. 본 연구 결과에서는 BMI와 전립선암 발병률과는 연관성을 확인 할 수 없었으며, BMI와 임상적 병기와는 다소 연관성이 있는 것으로 나타났으나 통계적 유의성은 없었다. 이러한 비만 환자를 대상으로 한 연구에서는 비만의 기준에 따라서 큰 차이가 유발될 수 있으며, 비만 환자의 경우 전립선암 진단 및 치료 방법 등에 있어서 다양한 편견 및 오류가 작용할 수 있을 것으로 생각된다. 따라서, 비만과 전립선암과의 명확한 연관성을 확인하기 위해서는 향후 비만에 영향을 미칠 수 있는 다양한 인자와 호르몬 측정 및 BMI 이외의 여러 가지 비만 지수 등의 측정을 포함한 대규모 임상연구가 필요하리라 생각된다.

  • PDF