• 제목/요약/키워드: Triple-A

검색결과 2,170건 처리시간 0.024초

Outcome of Inhaler Withdrawal in Patients Receiving Triple Therapy for COPD

  • Kim, Sae Ahm;Lee, Ji-Hyun;Kim, Eun-Kyung;Kim, Tae-Hyung;Kim, Woo Jin;Lee, Jin Hwa;Yoon, Ho Il;Baek, Seunghee;Lee, Jae Seung;Oh, Yeon-Mok;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • 제79권1호
    • /
    • pp.22-30
    • /
    • 2016
  • Background: The purpose of this study was to document outcomes following withdrawal of a single inhaler (step-down) in chronic obstructive pulmonary disease (COPD) patients on triple therapy (long-acting muscarinic antagonist and a combination of long-acting ${\beta}2$-agonists and inhaled corticosteroid), which a common treatment strategy in clinical practice. Methods: Through a retrospective observational study, COPD patients receiving triple therapy over 2 years (triple group; n=109) were compared with those who had undergone triple therapy for at least 1 year and subsequently, over 9 months, initiated inhaler withdrawal (step-down group, n=39). The index time was defined as the time of withdrawal in the step-down group and as 1 year after the start of triple therapy in the triple group. Results: Lung function at the index time was superior and the previous exacerbation frequency was lower in the step-down group than in the triple group. Step-down resulted in aggravating disease symptoms, a reduced overall quality of life, decreasing exercise performance, and accelerated forced expiratory volume in 1 second ($FEV_1$) decline ($54.7{\pm}15.7mL/yr$ vs. $10.7{\pm}7.1mL/yr$, p=0.007), but there was no observed increase in the frequency of exacerbations. Conclusion: Withdrawal of a single inhaler during triple therapy in COPD patients should be conducted with caution as it may impair the exercise capacity and quality of life while accelerating $FEV_1$ decline.

INTEGRAL REPRESENTATIONS FOR SRIVASTAVA'S HYPERGEOMETRIC FUNCTION HA

  • Choi, June-Sang;Hasanov, Anvar;Turaev, Mamasali
    • 호남수학학술지
    • /
    • 제34권1호
    • /
    • pp.113-124
    • /
    • 2012
  • While investigating the Lauricella's list of 14 complete second-order hypergeometric series in three variables, Srivastava noticed the existence of three additional complete triple hypergeometric series of the second order, which were denoted by $H_A$, $H_B$ and $H_C$. Each of these three triple hypergeometric functions $H_A$, $H_B$ and $H_C$ has been investigated extensively in many different ways including, for example, in the problem of finding their integral representations of one kind or the other. Here, in this paper, we aim at presenting further integral representations for the Srivatava's triple hypergeometric function $H_A$.

SUMMATION FORMULAS DERIVED FROM THE SRIVASTAVA'S TRIPLE HYPERGEOMETRIC SERIES HC

  • Kim, Yong-Sup;Rathie, Arjun Kumar;Choi, June-Sang
    • 대한수학회논문집
    • /
    • 제25권2호
    • /
    • pp.185-191
    • /
    • 2010
  • Srivastava noticed the existence of three additional complete triple hypergeometric functions $H_A$, $H_B$ and $H_C$ of the second order in the course of an extensive investigation of Lauricella's fourteen hypergeometric functions of three variables. In 2004, Rathie and Kim obtained four summation formulas containing a large number of very interesting reducible cases of Srivastava's triple hypergeometric series $H_A$ and $H_C$. Here we are also aiming at presenting two unified summation formulas (actually, including 62 ones) for some reducible cases of Srivastava's $H_C$ with the help of generalized Dixon's theorem and generalized Whipple's theorem on the sum of a $_3F_2$ obtained earlier by Lavoie et al.. Some special cases of our results are also considered.

Thermal Analysis on Triple-Passage Heat Exchangers for a Continuous Hot-Steel Tube Cooling System

  • Ko, Bong-Hwan;Park, Seung-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권1호
    • /
    • pp.10-18
    • /
    • 2002
  • The objective of present study is to analyze a concentric triple-passage heat exchanger for an optimal design of a continuous hot steel-tube cooling system, where a hot-steel tube line is passing through an antioxidant gas with a constant speed. Velocities and temperatures of the inert gas flowing between inner and outer tubes are calculated theoretically for laminar and numerically for turbulent flow regimes. From their profiles Nusselt numbers and friction factors are calculated (or various ratios of inner/outer tube radii and relative velocities. With these Nusselt numbers triple-passage heat exchangers are investigated for their thermal characteristics. It is shown that heat transfer coefficients based on ratios of average heat fluxes from inner and outer tubes might result in great errors for the temperature distributions of the flows, since local heat transfer coefficients for flows through an annulus are dependent on local wall heat flux ratios.

진공 및 이산화탄소 삼중유리 시스템의 최적 두께 및 열관류율 분석 (Analysis of the Optimal Thickness and the Heat Transmission for the Triple Glazing System with Vacuum and Carbon Dioxide Gaps)

  • 백상훈
    • 토지주택연구
    • /
    • 제11권3호
    • /
    • pp.61-68
    • /
    • 2020
  • Advanced glazing systems with excellent heat transmission values (Ug-Value) have been developed to reduce the energy consumption and the greenhouse gas emission. This study proposes a triple glazing system consisting of gaps with a vacuum and a carbon dioxide gas layer which is one of greenhouse gases. As a fundamental stage, this study is focused on calculating the optimal glazing thickness and the Ug-Value via a computer simulation, Therm & Window package. As the results, it was presented that the optimal thickness of the proposed triple glazing system is 22.2 mm, and the Ug-Value is 0.273 W/㎡·K. If this glazing system is to be applied to buildings, it could not only reduce building energy consumption but could also contribute to the treatment of carbon dioxide gas which is one of greenhouse gases.

Triple antibiotics와 관련한 치아 변색의 예방 (Prevention of tooth discoloration associated with triple antibiotics)

  • 김보나;송민주;신수정;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.119-122
    • /
    • 2012
  • Regenerative endodontics has a potential to heal a partially necrotic pulp, which can be beneficial for the continued root development and strengthening of immature teeth. For this purpose, triple antibiotic mixture of ciprofloxacin, metronidazole, and minocycline was recommended as intracanal medicament in an attempt to disinfect the root canal system for revascularization of a tooth with a necrotic pulp. However, discoloration of the tooth was reported after applying this. This case shows the idea for preventing the tooth discoloration using a delivery syringe to avoid the contact between the clinical crown and the antibiotics.

Linear Bipolar OTAs Employing Hyperbolic Function Circuits and Triple-Tail Cell

  • Matsumoto, Fujihiko;Noguchi, Yasuaki
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.763-766
    • /
    • 2002
  • This paper proposes design of new linear bipolar OTAs composed of an hyperbolic function circuit and a triple-tail cell. Two types of the OTAs are presented; one employs a hyperbolic sine circuit and the other contains a hyperbolic cosine circuit. The linear input voltage ranges of the proposed OTAs are wider than that of the conventional triple-tail cell, though the power dissipation is smaller. The results of SPICE simulation show that satisfactory characteristics are obtained.

  • PDF

필터 종류에 따른 Semi-volatile 화합물 이행 특성 (A study on the Delivery of Semivolatile Components in Cigarette Main Stream Smoke with the Filters)

  • 김정열;신창호
    • 한국연초학회지
    • /
    • 제19권2호
    • /
    • pp.124-128
    • /
    • 1997
  • Semivolatile components in mainstream smoke of cigarette attached the different type filter were analysed. Based on the main peak of GC profile, benzene, toluene, acetic acid, limonene, acetamide, pyridine, nicotine, phenol, pyrrole, and furfuryl alcohol were identified. The amount delivered of semivolatile components by each filter was evaluated with the ratio of areas of sample vs area% of ISTD. By comparing dual and triple filter to mono filter, the delivery amounts were 52% benzene, 62% toluene and 74% benzene, 84% toluene, respectively. The delivery amount of limonene which was known of tobacco taste component, were 52%, and 93% by dual and triple filter, respectively. Also, delivery amounts of acetic acid which was one of acidic compounds in smoke, were 86% and 83% by dual and triple filter, respectively. When adding the same amount of active carbon, the amounts delivered of vapour phase such as benzene and toluene by dual filter were lower than that of triple filter. But the delivery amounts of acetic acid and phenol by dual filter were higher than that of triple filter. This results assume that the pH of active carbon in filter affect to the adsorption or absorption of triacetin during filter making process.

  • PDF

공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구 (A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments)

  • 윤종호;안영섭;김병수;황상근
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

a-SiGe solar cell의 광학적 특성 (Effects of optical properties in hydrogenated amorphous silicon germanium alloy solar cells)

  • 백승조;박태진;김범준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.67.1-67.1
    • /
    • 2010
  • Triple junction solar cell을 위한 a-SiGe middle cell의 조건별 광학적 특성에 관한 연구를 실시하였다. a-SiGe I층은 GeH4 유량, 압력, H2 dilution ratio를 변화시켜 제조하였으며 전기적, 광학적 특성을 비교하여 최종적으로 선택된 조건을 triple junction solar cell에 적용하였다. a-SiGe I층은 Ge contents가 증가함에 따라 band gap은 감소하고 45% 이상의 조건에서는 700nm 전후 파장의 투과율이 감소하며, 압력이 감소함에 따라 band gap은 소폭 감소하나 700nm 전후 파장의 투과율은 증가하였다. 그리고 H2 ratio가 증가함에 따라 band gap은 소폭 감소하나 투과율에는 큰 변화가 없었다. 상기 결과를 바탕으로 최종적으로 선택된 조건에서 triple-junction solar cell을 제작하여 평가한 결과 초기 변환효율 9%의 결과를 얻었다.

  • PDF