• Title/Summary/Keyword: Triple Glazing System

Search Result 11, Processing Time 0.026 seconds

Analysis of the Optimal Thickness and the Heat Transmission for the Triple Glazing System with Vacuum and Carbon Dioxide Gaps (진공 및 이산화탄소 삼중유리 시스템의 최적 두께 및 열관류율 분석)

  • Baek, Sang-Hoon
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.61-68
    • /
    • 2020
  • Advanced glazing systems with excellent heat transmission values (Ug-Value) have been developed to reduce the energy consumption and the greenhouse gas emission. This study proposes a triple glazing system consisting of gaps with a vacuum and a carbon dioxide gas layer which is one of greenhouse gases. As a fundamental stage, this study is focused on calculating the optimal glazing thickness and the Ug-Value via a computer simulation, Therm & Window package. As the results, it was presented that the optimal thickness of the proposed triple glazing system is 22.2 mm, and the Ug-Value is 0.273 W/㎡·K. If this glazing system is to be applied to buildings, it could not only reduce building energy consumption but could also contribute to the treatment of carbon dioxide gas which is one of greenhouse gases.

Case Study on 5kWp Transparent Thin-Film BIPV System (5kW급 투광형 박막 BIPV시스템의 실증연구)

  • An, Young-Sub;Kim, Sung-Tae;Lee, Sung-Jin;Song, Jong-Hwa;Hwang, Sang-Kun;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.29-35
    • /
    • 2010
  • This study has been carried out empirical research on Transparent Thin-film BIPV modules, BIPV modules installed on the exterior of the building are applied a laminated module 1kWp, double-glazing module 3kWp and triple-glazing module 1kWp. Applied to the total capacity of BIPV modules are 5kWp. In this study, design and construction process of BIPV systems is presented. In addition, through monitoring of the BIPV system, the temperature and the power characteristics of each module were analyzed. During the measurement period, the module temperature measurement results, the maximum surface temperature of $51.5^{\circ}C$ triple-glazing BIPV module showed the highest, followed by double-glazing BIPV module $49.1^{\circ}C$, $44.7^{\circ}C$ laminated modules, respectively. Power output results, the daily average double-layer modules showed 4.10kWh/day, triple-glazing module 1.57kWh, respectively 1.81kWh laminated modules. In particular, the power efficiency of triple-glazing BIPV module was lower than the power efficiency of the laminated BIPV module. This phenomenon is considered to be affected by the module temperature. In the future, BIPV modules in this study the relationship between module temperature and power characteristics plans to identify.

A Study on the Heat Transfer Phenomenon through the Glazing System (창호를 통한 열전달 현상에 관한 연구)

  • Kang, Eun-Yul;Oh, Myung-Won;Kim, Byung-Sean
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments (공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo;Hwang, Sang-Kun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

An Evaluation of Application Possibility of Window System in the Building based on Optical Characteristics Analysis of DSSC (염료감응태양전지의 광학특성분석을 통한 건축창호 적용가능성 평가 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Jeong, Seon-Yeong;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.109-115
    • /
    • 2011
  • It can gain both the electric energy production and disperse of light at the same time if DSSC is applied in the building as window system. It means to help facade design and to be used in lighting, heating, cooling energy directly by applicating DSSC BIPV window that is possible to daylighting and materialization of color. For this, optical characteristics analysis that is basic step must take precedence. So, basic databases of DSSC are builded and optical performances according to the double and triple glazing are evaluated by analyzing spectral data of various colored DSSC. As a result, Green(4) has the highest visible transmittance that is 28.8%, and Blue(3) has the lowest that is 0.3%. And, in case of optical performance of Green(4) depending on the incidence angle, SHGC and Tsol are decreased sharply from more than $60^{\circ}C$. Finally, It is judged that Red(4), Green(1), (4), Blue(4) are suitable for application in office building because visible transmittance is high and solar heat gain coefficient is low relatively in spite of composing to double and triple glazing.

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF

The Study on the Zero-Energy House Prototype of Country House (농촌주택에 적합한 제로에너지 하우스의 프로토타입 연구)

  • Im, Kyung-Up;Kim, Bich-Na;Lee, Chul-Sung;Yoon, Jong-Ho;Jin, Kyeong-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.185-190
    • /
    • 2009
  • Due to the building energy consumption of total energy consumption of Korea takes over 24%, economizing building energy and using renewable energy resources is being required. To suggest the prototype of zero energy house of country house, the passive systems and active systems are applicated and simulated. In case of wall insulation system is applicated, the heating load of building is reduced. Also, clear triple pair glazing system reduced 2.1% of heating load of building. The amount of reducing heating load by infiltration is depending on the Heating system. In this model, the 0.3ACH made 14.6% saving on heating load from base infiltration 0.82ACH. The solar thermal system of active system could save 80% of DHW and PV system supplies electric power more than average consumption of year. Through the optimum process, the end use of zero energy house of country house is 36kWh/m2.yr and total energy consumption is reduced about 74.2%.

  • PDF

Study on High Performance Building Envelope for raising Building Energy Rating (건물에너지효율등급향상을 위한 고효율 건물외피 성능 연구)

  • Hyun, Jong-Hun;Hong, Sung-Hee;Park, Hyo-Soon;Choi, Moo-Hyuck
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.801-806
    • /
    • 2008
  • The best plan is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, influence, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case1,2) and vacuum or triple glazing can retrieves the investment with $120 and $$140{\sim}150$ per barrel each.

  • PDF

Study on Application and Economic Evaluation of New Insulation Material to Confront High Oil Price: Focus on an Apartment (고유가 대응을 위한 신단열재 적용과 경제성평가 연구 : 공동주택을 중심으로)

  • Hyun, Jong-Hun;Kim, Ji-Yeon;Park, Hyo-soon;Choi, Moo-Hyuck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.746-751
    • /
    • 2008
  • The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case 1, 2) and vacuum or triple glazing can retrieves the investment with $120 and $140$\sim$150 per barrel each.