• 제목/요약/키워드: Tree electrode system

검색결과 13건 처리시간 0.032초

Effect of Amino Silane Coupling Agent on the AC Electrical Breakdown Phenomena of Epoxy/Layered Silicate Nanocomposite in Needle-plate Electrodes

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권3호
    • /
    • pp.149-152
    • /
    • 2012
  • The effects of amino silane coupling agent on the AC electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were examined in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin by using our AC electric field apparatus. To measure the tree initiation and propagation and the breakdown rate, an alternating current (AC) of 10 kV (60 Hz) was applied to the specimen in needle-plate electrode arrangement with a $30^{\circ}C$ insulating oil bath. In the epoxy/amino silane system, the tree initiation time was 11.5 times higher and the breakdown time was 17.9 times higher than those of the neat epoxy resin. The tree initiation time in the epoxy/layered silicate (1 wt%) system with the amino silane was 2.0 times higher, and the breakdown time was 1.5 times higher than those of the epoxy/layered silicate (1 wt%) system.

초고압 전력 케이블 절연층의 Flow Pattern 방향각에 따른 전기 트리 개시 특성 비교 (Comparison of Electrical Tree Initiation According to Flow Pattern in EHV Power Cable Insulation)

  • 이승엽;김영호;조대희;이인호;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1532-1534
    • /
    • 1999
  • Electrical treeing phenomenon, regarded as pre-breakdown which accelerates aging process leading an insulation to the complete breakdown, is with no doubt extremely fatal to the performance of the insulation. Investigated in this paper is electrical treeing representing local dielectric failure according to flow pattern, the flow history of liquid polyethylene formed during the extrusion process. Experiments of electrical tree initiation by means of ramp tests were conducted using newly developed electrode system with point-to-point structure. Constant voltage tests were also carried out with the electrode system to estimate the life time of the insulation. Results were analyzed using statistical method such as Weibull distribution.

  • PDF

고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석 (Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics)

  • 강성화;홍현문;류부형
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

침전극의 곡율반경에 따른 트리개시전계 및 트리진전 특성 (Dependence of needle tip Curvature of the Inception Stress and Propagation of electrical tree)

  • 박영국;김완수;이홍규;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 1999
  • Inception and propagation of electrical tree and properties of Partial discharge(PD) pulses accompanying with tree as a function of needle tip radius in low density polyethylene were discussed. To study on these characteristics in different tip radius, we used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscope with computer and investigated the characteristics of the phase resolved PD pulses accompanying with propagation of electrical tree. The PD quantities detected and analysed were PD magnitude, mean phase angle, average discharge, and the statistical characteristics of the PD pulses. As the tip radius ${\gamma}$ increases, tree inception stress E$\sub$i/ converges to constance value. This result suggests that tree inception stress E$\sub$i/ increases due to stress relaxation when the tip radius is small. Branch-type electrical tree was formed When E$\sub$i/ is 640-750[kV/mm]. bush-type electrical tree when E$\sub$i/ is 370∼400[kV/mm], branch-like electrical tree when E$\sub$i/ is 370-400[kV/mm].

  • PDF

잔류염소 측정용 전기화학센서의 유효성 (Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement)

  • 김홍원;정남용
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

경화제 함량과 후기경화조건에 따른 DGEBA/MDA/SN계의 절연열화 특성 (Effects of Curing Agent Content and Post-curing Conditions on Dielectric Deterioration Characteristics of DGEBA/MDA/SN System)

  • 조영신;박수길;임기조;심미자;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.313-316
    • /
    • 1997
  • The effects of aromatic curing agent of MDA contents and post curing conditions on dielectric deterioration characteristics of DGEBA/MDA/SN system were investigated. The dielectric properties were measured by using needle-plane electrode geometry under the commercial AC high electric field application. As the curing agent content increased, the dielectric breakdown strength increased and then decreased slightly. All the trees initiated from the tip of needle electrode and the shape of the tree in this system was a dendrite type.

  • PDF

고분자 절연재료에서 전기트리 열화 및 절연파괴 현상 (Electrical Treeing Deterioration and Dielectric Breakdown Phenomena in Polymeric Insulator)

  • 조영신;김상욱
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.398-403
    • /
    • 1999
  • 폴리에틸렌과 에폭시 수지계 고분자 정연재료에서 발생하는 전기트리 열화 및 절연파괴 현상에 대해 연구하였다. 침-평판 전극구조를 갖는 블럭상 시편에 전기적 응력을 가하고 침 선단에서 발생하는 전기트리를 관찰하였다. 저밀도 폴리에틸렌에서 발생하는 전기트리 형상은 밀도가 매우 높은 부시상이었으며, 가교 풀려에틸렌에서는 가지형 전기트리가 관찰되었다. 에폭시 수지 에서는 첨가제 SN의 함량과 온도가 증가함에 따라 절연파괴 강도는 감소하였으며 전기트리는 더욱 복잡해졌다. 가교밀도가 높아 딱딱한 DGEBA/MDA 에폭시 수지계에서는 전도성 트리 경로 주위에 일련의 부채꼴 크랙이 관찰되었다.

  • PDF

LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석 (Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE)

  • 강성화;박영국;권순석;신태수;임기조
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.216-221
    • /
    • 1999
  • 전력용 케이블은 전선로의 지중화 추세에 따라 사용이 증가하고 있다. 케이블 절연체의 경우 장기간의 전압인가에 의해 열화 및 절연파괴 된다. 전력용 케이블의 절연파괴시 발생하는 사회/경제적 문제는 매우 심각한 것으로 알려져 있다. 절연체의 열화에 영향을 주는 요인은 매우 복잡하지만 그중에서도 전기트리 열화에 의한 파괴는 비교적 두꺼운 고체 유전체인 경우에 절연파괴 사고의 주된 원인이 되고 있다. 전기트리의 개시나 진전시 부분방전이 발생하므로 부분방전의 검출에 의해 전기트리의 발생 및 진전 양상을 관측할 수 있고 부분방전의 해석에 의해 절연재료의 잔여 수명을 예측할 수 있다. 본 논문에서는 고전압 전력용 케이블 절연재로써 광범위하게 사용되고 있는 저밀도 폴리에틸렌 시편에서의 전기트리 진전 양상을 비파괴 진단 기법에 의하여 검출하고자 내부 부분방전을 관측/해석하였다.

  • PDF

파이토그램을 이용한 월악산 기후요소, 토양환경 및 수목생장 장기간 모니터링 (Long-Term Monitoring of Climatic and Soil Factors, and Tree Growths in Worak Mountain Using Phytogram System)

  • 박원규;서정욱
    • 한국제4기학회지
    • /
    • 제14권2호
    • /
    • pp.101-107
    • /
    • 2000
  • Phytogram을 이용하여 월악산에 자라는 침엽수류의 비대생장과 형성층의 전기화학적 활성을 기온, 토양수분, 토양온도, 광량 등과 함께 1996년 5월부터 1998년 10월초까지 28개월간 1시간 간격으로 연중 모니터링 함으로써, 이들 수목의 생장에 관여하는 기후인자를 추출하여 연륜을 이용한 고기후 복원과 기후변화(온난화와 강수량 변화)에 따른 수목생장 예측자료로 활용하고자 하였다. Phytogram은 미세전극을 식물체의 사부와 목부 사이에 삽입하여 형성층에서의 산소, 수소이온, 수분을 측정하는 전기화학적 시스템으로 운용되는 기기로서 토양수분, 토양온도, 기온, 광량 등 환경조건과 수목의 비대생장을 기록할 수 있었다. 직경생장개시 시기는 낙엽송, 소나무, 리기다소나무 순이었다. 3 수종 모두 생장초기 생장속도가 빠르며 이때의 환경조건이 이들 수종의 생장량에 가장 큰 영향을 주었다. 즉 장마철 이전(5월과 6월)의 수분조건이 생장량을 가장 크게 좌우하였다. Dendrometer(직경생장)와 proton(수소이온)은 증산작용에 의해 아침부터 오후까지 감소하여 16시에 최저가 되고, hydration(수분)은 아침부터 증가하기 시작하여 16시에 최대가 되었다.

  • PDF

HVDC 서브모듈용 커패시터의 고장 분석 (Failure analysis of capacitor for sub-module in HVDC)

  • 강필순;송성근
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.941-947
    • /
    • 2018
  • 일반적으로 커패시터는 빈번한 충 방전으로 시스템의 수명에 큰 영향을 미친다. 본 논문에서는 고전압, 대전류의 HVDC 서브모듈용 필름 커패시터의 핵심 고장원인을 분석하여 커패시터의 설계 및 제조공정의 주의사항을 분석한다. 먼저 커패시터의 FMEA 수행을 통해 고장원인, 고장모드, 고장영향에 대해 분석한다. 커패시터의 고장에 가장 큰 영향을 주는 고장원인과 영향을 정량적으로 평가하기 위해 커패시터에 대한 고장나무(Fault-tree)를 제시하고 설계인자와 구동환경의 조건에 따른 고장률을 분석한다. 커패시터 고장의 핵심 원인이 커패시턴스 변화에 있음을 확인하고, 커패시터의 고장률 저감을 위해서 커패시터의 설계와 제조공정 중 온도상승, 코로나 발생, 전극팽창, 절연거리 감소를 최소화할 필요가 있음을 검증한다.