• Title/Summary/Keyword: Tree Electrode System

Search Result 13, Processing Time 0.018 seconds

Effect of Amino Silane Coupling Agent on the AC Electrical Breakdown Phenomena of Epoxy/Layered Silicate Nanocomposite in Needle-plate Electrodes

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.3
    • /
    • pp.149-152
    • /
    • 2012
  • The effects of amino silane coupling agent on the AC electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were examined in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin by using our AC electric field apparatus. To measure the tree initiation and propagation and the breakdown rate, an alternating current (AC) of 10 kV (60 Hz) was applied to the specimen in needle-plate electrode arrangement with a $30^{\circ}C$ insulating oil bath. In the epoxy/amino silane system, the tree initiation time was 11.5 times higher and the breakdown time was 17.9 times higher than those of the neat epoxy resin. The tree initiation time in the epoxy/layered silicate (1 wt%) system with the amino silane was 2.0 times higher, and the breakdown time was 1.5 times higher than those of the epoxy/layered silicate (1 wt%) system.

Comparison of Electrical Tree Initiation According to Flow Pattern in EHV Power Cable Insulation (초고압 전력 케이블 절연층의 Flow Pattern 방향각에 따른 전기 트리 개시 특성 비교)

  • Lee, Seung-Yoo;Kim, Young-Ho;Cho, Dae-Hee;Lee, In-Ho;Park, Wan-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1532-1534
    • /
    • 1999
  • Electrical treeing phenomenon, regarded as pre-breakdown which accelerates aging process leading an insulation to the complete breakdown, is with no doubt extremely fatal to the performance of the insulation. Investigated in this paper is electrical treeing representing local dielectric failure according to flow pattern, the flow history of liquid polyethylene formed during the extrusion process. Experiments of electrical tree initiation by means of ramp tests were conducted using newly developed electrode system with point-to-point structure. Constant voltage tests were also carried out with the electrode system to estimate the life time of the insulation. Results were analyzed using statistical method such as Weibull distribution.

  • PDF

Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics (고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석)

  • 강성화;홍현문;류부형
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

Dependence of needle tip Curvature of the Inception Stress and Propagation of electrical tree (침전극의 곡율반경에 따른 트리개시전계 및 트리진전 특성)

  • 박영국;김완수;이홍규;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.59-62
    • /
    • 1999
  • Inception and propagation of electrical tree and properties of Partial discharge(PD) pulses accompanying with tree as a function of needle tip radius in low density polyethylene were discussed. To study on these characteristics in different tip radius, we used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscope with computer and investigated the characteristics of the phase resolved PD pulses accompanying with propagation of electrical tree. The PD quantities detected and analysed were PD magnitude, mean phase angle, average discharge, and the statistical characteristics of the PD pulses. As the tip radius ${\gamma}$ increases, tree inception stress E$\sub$i/ converges to constance value. This result suggests that tree inception stress E$\sub$i/ increases due to stress relaxation when the tip radius is small. Branch-type electrical tree was formed When E$\sub$i/ is 640-750[kV/mm]. bush-type electrical tree when E$\sub$i/ is 370∼400[kV/mm], branch-like electrical tree when E$\sub$i/ is 370-400[kV/mm].

  • PDF

Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement (잔류염소 측정용 전기화학센서의 유효성)

  • Kim, Hong-Won;Chung, Nam-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

Effects of Curing Agent Content and Post-curing Conditions on Dielectric Deterioration Characteristics of DGEBA/MDA/SN System (경화제 함량과 후기경화조건에 따른 DGEBA/MDA/SN계의 절연열화 특성)

  • 조영신;박수길;임기조;심미자;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.313-316
    • /
    • 1997
  • The effects of aromatic curing agent of MDA contents and post curing conditions on dielectric deterioration characteristics of DGEBA/MDA/SN system were investigated. The dielectric properties were measured by using needle-plane electrode geometry under the commercial AC high electric field application. As the curing agent content increased, the dielectric breakdown strength increased and then decreased slightly. All the trees initiated from the tip of needle electrode and the shape of the tree in this system was a dendrite type.

  • PDF

Electrical Treeing Deterioration and Dielectric Breakdown Phenomena in Polymeric Insulator (고분자 절연재료에서 전기트리 열화 및 절연파괴 현상)

  • Cho, Yeong-Sin;Kim, Sang-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.398-403
    • /
    • 1999
  • Studies on the electrical treeing deterioration and dielectric breakdown phenomena in the polymeric insulator of polyethylene and epoxy resin were carried out. Block type samples with needle-plane electrode geometry were electrically stressed and the tree pattern from the needle tip was observed. In LDPE the density of electrical tree was very high and its pattern was bush type. For the case of XLPE, branched tree was observed. As temperature and SN content increased, the dielectric breakdown voltage decreased and the treeing phenomena became more complicated. Fan type cracks were observed around the conducting tree path in the brittle DGEBA/MDA system.

  • PDF

Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE (LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석)

  • Kang, S.H.;Park, Y.G.;Kwon, S.S.;Shin, T.S.;Lim, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.216-221
    • /
    • 1999
  • The correlation between propagation of electrical tree and internal partial discharges is discussed. We use specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope and investigated the characteristics of the partial discharge (PD) pulses accompanying with propagation of electrical tree. In the specimens with needle-shaped void, the tree propagates branch type. The length of the tree has good linear relation with average discharge power of PD pulses. In the specimens without needle-shaped void, the tree grows bush type tree. The correlation between the area of the tree and the average discharge power of PD pulses has linear relation.

  • PDF

Long-Term Monitoring of Climatic and Soil Factors, and Tree Growths in Worak Mountain Using Phytogram System (파이토그램을 이용한 월악산 기후요소, 토양환경 및 수목생장 장기간 모니터링)

  • 박원규;서정욱
    • The Korean Journal of Quaternary Research
    • /
    • v.14 no.2
    • /
    • pp.101-107
    • /
    • 2000
  • Using the phytogram system, this study monitored hourly environmental factors(climate and soil), and radial growths and cambium activities of conifers in Worak mountain for 28 months from May 1996 to October 1998 to examine the influences of climatic factors on tree growths/carnbium activities of conifers in Worak Mountain, Korea. The phytogram system first puts a fine electrode into cambial zone. This device can automatically record environmental factors and cambium electrochemistry(hydration and proton levels). Dendrometers are attached to the phytogram for monitoring seasonal dynamics of cambial growth. We compared the results of radial growth by species and by diameter class. The growth decreased in order of Larix leptolepis, Pinus densiflora and Pinus rigida. Pre-monsoon growths were fast and May-June moisture regime was the most critical for all species. In the middle of September, radial growths were finished. The proton level and stem diameter reached the minimum at 4 p.m. On the other hand, the hydration level reached the maximum at 4 p.m. This diurnal change resulted from transpiration and the release of water from phloem storage to sapwood through xylem stream.

  • PDF

Failure analysis of capacitor for sub-module in HVDC (HVDC 서브모듈용 커패시터의 고장 분석)

  • Kang, Feel-soon;Song, Sung-Geun
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.941-947
    • /
    • 2018
  • In general, capacitors have a large influence on the life of the system due to frequent charging and discharging. In this paper, we analyze the cause of the core failure of high voltage, high current HVDC sub-module film capacitor and analyze the precautions of the capacitor design and manufacturing process. First, the cause of the fault, the failure mode, and the effect are analyzed through the FMEA of the capacitor. To quantitatively evaluate the causes and effects of faults that have the greatest effect on the failure of a capacitor, a fault tree for the capacitor is presented and the failure rate is analyzed according to the design parameters and the driving conditions. It is verified that the main cause of capacitor failure is the capacitance change, and it is necessary to minimize the temperature rise, corona occurrence, electrode expansion, and insulation distance decrease during capacitor design and manufacturing process in order to reduce the failure rate of the capacitor.