• Title/Summary/Keyword: Transportation Capacity

Search Result 820, Processing Time 0.025 seconds

Study on Compressive Strength of Cast-in-situ Concrete Pile (현장타설 말뚝의 수중부 콘크리트 강도에 대한 고찰)

  • Shim, Jae-Won;Jeon, Kyung-Soo;Kim, Nag-Young;Park, Chan-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.564-569
    • /
    • 2009
  • Due to the uneasy controllable qualities of the substructures such as pile and foundation, which are laid on underground, geotechnical engineers have applied conservative criteria to them. Therefore, the specification criterion of cast-in-situ concrete pile, which allows only one fourth of the compressive strength of structural capacity, has forced geotechnical designers to consider the most uneconomical design regardless of satisfying the grade of quality-control, required performance, construction cost and so on. Thus, in this study, we proposed the less conservative criteria on the strength of concrete pile, based on the experimental testing results of cast-in-situ concrete piles.

  • PDF

An examination of the analysis of intermodal travel patterns using a stated preference survey for KTX (고속철도 선호조사를 통한 교통수단간 연계특성조사)

  • 이진선;김현웅
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.35-40
    • /
    • 2002
  • The Korean high speed railway system is scheduled to open sometime in 2004. To fulfill its duties, it is essential to view intermodalism in easy access to high speed railway station. To study travelers' choice of mode and to make improvements the transfer, a SP survey of 3628 was conducted in national level in the fall of 2001. An understanding of KTX passenger mode choice is crucial for station-related facility capacity planning. Development of main and regional high speed stations, as well as changes in the roadway and railroad transportation system for station access, will influence the relative demand for traveling by train from compel ing other transportation mode. The research described here was designed to derive a general overview of the basic travel patterns with an emphasis on intermodal transportation system.

  • PDF

A Study on the Outbound Logistics Network Rationalization of Domestic Automobile Industry (국내 완성차 물류 네트워크 합리화 방안 연구)

  • 김대기;조한홍
    • Journal of Distribution Research
    • /
    • v.7 no.1
    • /
    • pp.1-20
    • /
    • 2002
  • Many of logistics-related research in automobile industry has focused on inbound logistics and procurement. Research into outbound logistics is relatively few. As a starting research into outbound logistics in automobile industry, this paper examined its logistics network problems with three aspects - location strategy, inventory strategy and transportation strategy. We proposed alternatives of logistics network design resolution, and presented three practical scenarios based on those alternatives. Based on interview, on-site visit and internal data collection processes, we identified major domestic outbound logistics problems such as redundant logistics bases, inefficient delivery policy, insufficient inventory capacity, inventory stock quality deterioration, inefficient transportation system, and etc. In order to cope with those problems, we proposed such strategic alternatives as introduction of hub-and-spoke system, integration of logistics bases, introduction of (automatic) parking building, diversification of transportation mode, and etc. At the same time, we constructed three practically executable scenarios based on those ideas. The first is "Center Hub" scenario, the second is "Metropolitan Hub" scenario. The third and last scenario is "Regional Consolidation of Warehouses (distribution centers)".

  • PDF

Development of an Appraisal Model for Petroleum Storage and Transport Policy for a Petroleum Production Company (XX정유사의 석유제품 저유 및 수송정책평가모형의 개발)

  • 노정현;임채욱
    • Journal of Korean Society of Transportation
    • /
    • v.11 no.3
    • /
    • pp.49-66
    • /
    • 1993
  • The successful management of logistics in an organization requires the careful coordination and manipulation of both movement and storage. In this study, we can show what is the most efficient and the cheapest method to transport the petroleum products under a few constraints with the model of linear programming. And also, the model can give some important informations so as what is the best coverages of each terminals by types, how many products should be exchanged among each companies and which terminals or complexes are economically prior to the others. Even we can understand that the duality is one of the useful measures to evaluate the economical efficiencies of transportation and storage related elements such as complex and terminal location, transport mode, storage tankage capacity and in/outflow facilities of terminals etc.

  • PDF

A software tool for integrated risk assessment of spent fuel transportation and storage

  • Yun, Mirae;Christian, Robby;Kim, Bo Gyung;Almomani, Belal;Ham, Jaehyun;Lee, Sanghoon;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.721-733
    • /
    • 2017
  • When temporary spent fuel storage pools at nuclear power plants reach their capacity limit, the spent fuel must be moved to an alternative storage facility. However, radioactive materials must be handled and stored carefully to avoid severe consequences to the environment. In this study, the risks of three potential accident scenarios (i.e., maritime transportation, an aircraft crashing into an interim storage facility, and on-site transportation) associated with the spent fuel transportation process were analyzed using a probabilistic approach. For each scenario, the probabilities and the consequences were calculated separately to assess the risks: the probabilities were calculated using existing data and statistical models, and the consequences were calculated using computation models. Risk assessment software was developed to conveniently integrate the three scenarios. The risks were analyzed using the developed software according to the shipment route, building characteristics, and spent fuel handling environment. As a result of the risk analysis with varying accident conditions, transportation and storage strategies with relatively low risk were developed for regulators and licensees. The focus of this study was the risk assessment methodology; however, the applied model and input data have some uncertainties. Further research to reduce these uncertainties will improve the accuracy of this model.

Experimental and analytical study on RC beam reinforced with SFCB of different fiber volume ratios under flexural loading

  • Lin, Jia-Xiang;Cai, Yong-Jian;Yang, Ze-Ming;Xiao, Shu-Hua;Chen, Zhan-Biao;Li, Li-Juan;Guo, Yong-Chang;Wei, Fei-Fei
    • Steel and Composite Structures
    • /
    • v.45 no.1
    • /
    • pp.133-145
    • /
    • 2022
  • Steel fiber composite bar (SFCB) is a novel type of reinforcement, which has good ductility and durability performance. Due to the unique pseudo strain hardening tensile behavior of SFCB, different flexural behavior is expected of SFCB reinforced concrete (SFCB-RC) beams from traditional steel bar reinforced concrete (S-RC) beams and FRP bar reinforced concrete (F-RC) beams. To investigate the flexural behavior of SFCB-RC beam, four points bending tests were carried out and different flexural behaviors between S/F/SFCB-RC beams were discussed. An flexural analytical model of SFCB-RC beams is proposed and proved by the current and existing experimental results. Based on the proposed model, the influence of the fiber volume ratio R of the SFCB on the flexural behavior of SFCB-RC beams is discussed. The results show that the proposed model is effective for all S/F/SFCB-RC flexural members. Fiber volume ratio R is a key parameter affecting the flexural behavior of SFCB-RC. By controlling the fiber volume ratio of SFCB reinforcements, the flexural behavior of the SFCB-RC flexural members such as bearing capacity, bending stiffness, ductility and repairability of SFCB-RC structures can be designed.

An Experimental Study on the Static Load Capacity of T-Type Tension Joints with High Tension Bolt (고장력볼트 T-인장이음의 정적내력에 관한 실험적 연구)

  • Lee, Seung Yong;Choi, Jun Hyeok;Kim, Kyong Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • The tension type joint is a mechanically very efficient connection method, as it directly uses the load capacity of base metal or high tension bolt, the reduction of the number of drilling hole and fastening and the fatigue resistance. It is applied to the joint of girder and cross beam, horizontal joints of towers, beam to column joints, the secondary member joints of deck floor ends, and brackets. In this paper, static load tests for the T-type tension joint were conducted to investigate the structural behavior of the joint. The parameters were bolt diameter, flange thickness, and the reduction of clamping force of the joint. The failure modes and load capacity of joints and the effects of flange thickness, bolt diameter and clamping force were investigated.

A Study on Model Development of Pedestrian Crossing Capacity at Unsignalized Crosswalks with Pedestrian Refuge Area (중앙분리대 대기공간이 있는 비신호 횡단보도에서의 보행자 횡단용량 모형식 개발)

  • 김상구
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.4
    • /
    • pp.103-111
    • /
    • 2003
  • This study proposes methodology deterimining a basic pedestrian crossing capacity that plays a critical role in the installation of pedestrian signal at the crosswalks. The methodology is based on the pattern of vehicle arrived at the crosswalks. Erlang distribuion is used as headway distribution that can cover the various levels of flow rate. Models using Erlang distribution are represented by Erlang parameter (K) of 1, 2, or 3 at 2-, 4-, or 6-lane roadway in both directions. In addition, this study considered the only type of road with a pedestrian refuge area in the median that is used to wait for the allowable gap provided by the flow of another direction. As a result, the pedestrian capacity decreases as flow rate increases and Erlang parameter increases for the road with the pedestrian refuge. This study develops the models to determine the pedestrian capacity under a variety of flow rates and the outcomes of this study could be used as the criteria for the determination of the installation of pedestrian signal or for the provision of pedestrian refuge in the median of road.

An Economical Efficiency Comparison for Extend Method of Container Terminal Yard Scale followed by the Call of the Mega Ship (초대형 컨테이너선박의 기항에 따른 컨테이너 터미널 장치장 규모 확대방안의 경제성 비교)

  • Song, Yong-Seok
    • Journal of Navigation and Port Research
    • /
    • v.33 no.5
    • /
    • pp.353-359
    • /
    • 2009
  • Most domestic container terminals are lack of container storage capacity compared to the throughput of container. The main reason is the difference between the theoretical capacity applied to the development of terminals and the real capacity of a berth Another reason seems to be the increase of the container crane in number per berth to match the need for the getting larger vessel, which is resulted from the increase of the berth capacity from the start. This study, therefore, aims to suggest the economic size of container yard by comparing the existing one. For this the berth capacity was recalculated, the required yard size derived considering up to 10,000TEU vessel and then cost comparison done.

Bond Capacity of Near-Surface-Mounted FRP in Concrete Corresponding to Fire-Protection Method (콘크리트에 표면매립보강된 FRP의 내화단열방법에 따른 부착성능)

  • Lim, Jong-wook;Kim, Tae-hwan;Seo, Soo-yeon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.1
    • /
    • pp.3-10
    • /
    • 2019
  • The purpose of this paper is to find the fire-protection method for keeping on the bond capacity of Near-Surface-Mounted (NSM) FRP under high temperature. Experiments have been carried out to evaluate the bond capacity of NSM FRP by using CFRP-plates and to confirm the heat transfer to the concrete block when the refractory insulation is attached to the surface of NSM FRP. Bond test of NSM FRP under room temperature was conducted to obtain the maximum bond strength. And then a heating tests were carried out with keeping the bond stress of 30% of the maximum bond strength. As a result, the bond capacity of NSM FRP was disappeared when the temperature at epoxy reached to its glass transition temperature (GTT). In order to secure the bond capacity of the NSM FRP, it is necessary to protect the front as well as side by using insulation materials.