• Title/Summary/Keyword: Transport loss

Search Result 600, Processing Time 0.036 seconds

A Study on Path Loss Prediction for the PNG of Russia Using the Free Space Model and the Hata Model (자유 공간 모델과 하타 모델을 이용한 러시아 PNG 지역의 경로 손실 예측에 관한 연구)

  • Park, Kyung-Tae;Cho, Hyung-Rae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.87-92
    • /
    • 2011
  • In this paper, we got the 800 ~ 900 MHz path loss model for Russia PNG area using the free space model and the Okumura-Hata Model. In order to add new regional properties to the existing path loss model, the mean square error technique is used to obtain the correction factor. The correction factors for the free space and the Hata model are 28, 13 dB respectively. By applying this correction factors, the new Russain PNG path loss model is proposed.

AC transport current loss analysis for a face-to-face stack of superconducting tapes

  • Yoo, Jaeun;Youm, Dojun;Oh, SangSoo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.34-38
    • /
    • 2013
  • AC Losses for face to face stacks of four identical coated conductors (CCs) were numerically calculated using the H-formulation combined with the E-J power law and the Kim model. The motive sample was the face to face stack of four 2 mm-wide CC tapes with 2 ${\mu}m$ thick superconducting layer of which the critical current density, $J_c$, was $2.16{\times}10^6A/cm^2$ on IBAD-MgO template, which was suggested for the mitigation of ac loss as a round shaped wire by Korea Electrotechnology Research Institute. For the calculation the cross section of the stack was simply modeled as vertically aligned 4 rectangles of superconducting (SC) layers with $E=E_o(J(x,y,t)/J_c(B))^n$ in x-y plane where $E_o$ was $10^{-6}$ V/cm, $J_c$(B) was the field dependence of current density and n was 21. The field dependence of the critical current of the sample measured in four-probe method was employed for $J_c$(B) in the equation. The model was implemented in the finite element method program by commercial software. The ac loss properties for the stacks were compared with those of single 4 cm-wide SC layers with the same critical current density or the same critical current. The constraint for the simulation was imposed in two different ways that the total current of the stack obtained by integrating J(x,y,t) over the cross sections was the same as that of the applied transport current: one is that one fourth of the external current was enforced to flow through each SC. In this case, the ac loss values for the stacks were lower than those of single wide SC layer. This mitigation of the loss is attributed to the reduction of the normal component of the magnetic field near the SC layers due to the strong expulsion of the magnetic field by the enforced transport current. On the contrary, for the other case of no such enforcement, the ac loss values were greater than those of single 4cm-wide SC layer and. In this case, the phase difference of the current flowing through the inner and the outer SC layers of the stack was observed as the transport current was increased, which was a cause of the abrupt increase of ac loss for higher transport current.

The Influence on self Field Losses in 2nd Stage Superconducting Cable for Different Twist Direction of Filaments (2중 연선 초전도 케이블에서 소선내의 필라멘트의 트위스트 방향이 자기자계 손실에 미치는 영향)

  • 이지광;차귀수;정희원
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.1
    • /
    • pp.38-41
    • /
    • 1999
  • Strands composing multistage superconducting cables for AC power applications have twisted structure in each stage for lower AC loss and higher stability. So, when transport currents flow in a cable, each strand is exposed to longitudinal and azimuthal magnetic fields produced by transport current flowing in strand itself and Iongitudinal and transverse magnetic fields by transport current flowing in twisted cable. In this paper. we study the influence on self field lesses generated in second stage superconducting cable for different twist direction of filaments in a strand considering twist of strands in cables.

  • PDF

Modeling As(III) and As(V) adsorption and transport from water by a sand coated with iron-oxide colloids

  • Ko, Il-Won;Lee, Cheol-Hyo;Kim, Kyoung-Woong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.243-247
    • /
    • 2004
  • Tile development of a porous iron-oxide coated sand filter system can be modelled with the analytical solution of tile transport equation in order to obtain the operating parameters and investigate the mechanism of arsenic removal. The adsorbed amount from the model simulation showed the limitation of adsorption removal during arsenic transport. A loss reaction term in the transport equation plays a role in the mass loss in column conditions, and then resulted into the better model fitting, particularly, for arsenate. Further, the competitive oxyanions delayed the breakthrough near MCL (10 $\mu$g/L) due to the competitive adsorption. This is the reason why arsenate can be strongly attracted in tile interface of an iron-oxide coated sand, and competing oxyanions can occupy the adsorption sites. Therefore, arsenic retention was regulated by non-equilibrium of arsenic adsorption in a porous iron-oxide coated sand media. The transport-limited process seemed to be affect the arsenic adsorption by coated sand.

  • PDF

Influence of non-uniform current distribution on transport ac loss in Bi-2223/Ag tapes (불균일 전류분포가 Bi-2223/Ag 초전도선재의 통전손실에 미치는 영향)

  • Choi, S.;Nah, W.;Joo, J.;Kim, J.H.;Ryu, K.W.;Sohn, M.H.;Kwon, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1240-1242
    • /
    • 2005
  • In this study, we estimate the transport current loss of Bi-2223/Ag tapes with non-uniform current distribution. The conductor was consisted of three Bi-2223/Ag tapes and the each tapes were attached in parallel. The loss of conductor was investigated both numerical and experimental methods. The numerical code to predict ac loss was developed, and finite element method was introduced. It contained intrinsic properties of superconducting tape, which was obtained from nonlinear current voltage relation with external magnetic field and its orientation. Two results were compared and discussed. They showed good agreements with each other.

  • PDF

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF

The Study on the Complex Causation of Loss in Marine Insurance (해상보험(海上保險)에서의 복합인과관계(複合因果關係)에 관한 연구(硏究))

  • Park, Sung-Cheul
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.15
    • /
    • pp.119-136
    • /
    • 2001
  • The purpose of this paper is to consider how to decide the cause of loss or damage to the transport goods when maritime accident occurs. In marine insurance, the underwriter is liable for any loss or damage proximately caused by a risk insured(MIA Art.55). So it is very important to determine the proximate cause of loss or damage to ascertain whether it is to be recoverable under the policy. But there is no definite conception or rule what is the proximate cause. It was left to the tribunal as a question of fact. In this paper, I will suggest the general rules to determine the proximate cause of loss or damage of the transport goods in marine insurance. First, in MIA 1906, there is the rule of proximate causation and it has been established the effective causation by cases since 1918. Second, in Institute Cargo Clauses(B) & (C), there are rules of considerably relaxed standards to determine the causation of loss of or damage using the "attributable to" and "caused by" basis. Third, it is noted, under the complex causation situation, there are difference basises to decide the liability of underwriters between the case of successive occurrence of single risk and the case of concurrent occurrence of several risks. Forth, in practice, it couldn't be ascertained the underwrier's liability by a definite rule and it should be fully considered the circumstances and conditions of the loss.

  • PDF

STEAM GENERATOR TUBE INTEGRITY ANALYSIS OF A TOTAL LOSS OF ALL HEAT SINKS ACCIDENT FOR WOLSONG NPP UNIT 1

  • Lim, Heok-Soon;Song, Tae-Young;Chi, Moon-Goo;Kim, Seoung-Rae
    • Nuclear Engineering and Technology
    • /
    • v.46 no.1
    • /
    • pp.39-46
    • /
    • 2014
  • A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.