• 제목/요약/키워드: Transmission tower foundation

검색결과 33건 처리시간 0.026초

가공송전철탑 경량화 설계에 관한 연구 (A Study of the Slim Design of Overhead Transmission Tower)

  • 이정원;이원교
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.560-565
    • /
    • 2010
  • This paper presents the design factor of an overhead transmission tower structure in order to reduce the tower weight. The behaviour of transmission tower structures are affected by the horizontal angle of the tower structure, the equivalent wind pressure group, the slope of the main post of the tower, the separation of the internode and the use of high-strength materials in their construction. Tower weight can be reduced by approximately 30% reduce weight by means of optimal design based on a consideration of all the above factors. In addition, the design of the foundation of the tower with the shear key installation to increase horizontal support together with a modified angle of inclination to the ground can reduce by about 37% the amount of concrete used during construction. The area of ground disturbed by the construction of the tower foundation can thus be reduced by approximately 33%. Therefore it is possible to build an environmently-friendly T/L tower with the mechanical properties of existing towers.

점토지반에 근입된 모형송전철탑 연결형 기초의 수평거동분석 (The analysis of lateral behavior of connected foundation for transmission tower in clay)

  • 경두현;송원준;이준환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.629-637
    • /
    • 2010
  • In this study, we analyzed lateral behavior of connected foundation for transmission tower in clay. For this study, we performed model lateral load test, measured load-displacement curve of connected foundation. For the tests, we manufactured connected foundation model that consider a change of rigidity, installed various measuring sensors for understanding of elements and general foundation behavior. From the test results, we measured load capacities using various methods, compared and analyzed these capacities.

  • PDF

점토지반에서 하중특성 및 연결보조건에 따른 송전철탑용 연결형 말뚝기초의 특성 분석 (Analysis of Characteristics of Connected-pile Foundations for Transmission Tower according to Changes of Load and Connection Beam Conditions in Clay)

  • 경두현;이준환;백규호;김영준;김대홍
    • 한국지반공학회논문집
    • /
    • 제29권10호
    • /
    • pp.5-18
    • /
    • 2013
  • 부등침하는 연약지반에 시공되는 철탑기초에 있어서 주요한 손상을 야기한다. 송전철탑용 연결형 말뚝기초는 연약지반에서의 송전철탑기초의 부등침하를 방지하기 위한 구조물로서, 주기초체와 주기초체 사이에 위치하여 기초를 연결하는 연결보로 구성된다. 본 연구에서는 송전용 철탑기초에 작용하는 연결보의 영향을 조사하기 위하여, 전라북도에 위치한 건설현장에서 24회의 모형재하시험을 수행하였다. 시험에서는 다양한 하중조건과 연결보 조건이 고려되었으며, 시험결과 수평하중에 의한 연결형 말뚝기초의 발생변위가 철탑에 작용하는 수평하중의 각도에 따라 달라지는 것으로 나타났다. 연결형 기초의 침하는 연결보의 강성이 증가할수록 감소하였으며, 수평지지력은 수평하중이 재하되는 철탑의 높이가 낮을수록 증가하였고, 파괴시점에서의 하중의 크기는 대부분의 경우 하중재하방향에 상관없이 유사한 것으로 나타났다.

점토지반에 근입된 송전철탑 연결형 말뚝기초의 저항력증가계수 (Resistance Increasing Factor of Connected-pile Foundation for Transmission Tower in Clay)

  • 경두현;이준환;백규호;김대홍
    • 한국지반공학회논문집
    • /
    • 제28권8호
    • /
    • pp.31-41
    • /
    • 2012
  • 연약지반에 건설되는 송전철탑 말뚝기초는 부등침하로 인한 철탑구조체의 손상을 유발 할 수 있다. 이에 따라 일본과 미국에서는 철탑을 지지하는 각 기초부를 연결보로 연결한 연결형기초의 사용을 추천하고 있다(TEPCO 1988, IEEE 2001). 연결형 말뚝기초의 저항력증가계수는 연결체의 영향으로 인하여 증가되는 연결형 말뚝기초의 저항력의 증가량을 나타낸다. 본 연구에서는 점토지반에 근입된 송전철탑 연결형말뚝 기초의 모형수평재하시험을 수행하여 연결형 말뚝기초의 저항력증가계수를 도출하였다. 본 시험은 실트질 점토지반에서 수행되었으며, 수평하중의 재하높이와 재하각도, 말뚝기초를 연결하는 연결체의 강성을 변화시켜 다양한 조건상에서의 저항력 증가계수를 도출하였다. 본 연구에서 도출된 저항력 증가계수는 송전철탑의 하중작용높이와 기초를 연결하는 연결체의 강성에 대한 함수로 나타났으며, 도출된 증가계수를 통하여 연결형 말뚝기초의 저항력을 산정한 결과 측정결과와 비교적 일치하는 것으로 나타났다.

Field measurements of wind-induced transmission tower foundation loads

  • Savory, E.;Parke, G.A.R.;Disney, P.;Toy, N.;Zeinoddini, M.
    • Wind and Structures
    • /
    • 제1권2호
    • /
    • pp.183-199
    • /
    • 1998
  • This paper discusses some of the findings arising from long-term monitoring of the wind effects on a transmission tower located on an exposed site in South-West England. Site wind speeds have been measured, together with the foundation loads at the base of each of the four legs. The results show good correlation between the wind speeds and leg strains (loads) for a given wind direction, as expected, for wind speeds in excess of 10 m/s. Comparisons between the measured strains and those determined from the UK Code of Practice for lattice towers (BS8100), for the same wind speed and direction, show that the Code over-estimates most of the measured foundation loads by a moderate amount of about 14% at the higher wind speeds. This tends to confirm the validity of the Code for assessing design foundation loads. A finite element analysis model has been used to examine the dynamic behaviour of the tower and conductor system. This shows that, in the absence of the conductor, the tower alone has similar natural frequencies of approximately 2.2 Hz in the both the first (transversal) and second (longitudinal) modes, whilst for the complete system and conductor oscillations dominate, giving similar frequencies of approximately 0.1 Hz for both the first and second modes.

가공 송전 철탑기초 설계 및 시공 방법 연구 - 심형기초를 중심으로 - (A Study on the Transmission Tower Foundation Design and Construction Method - A Focus of Cylindrical Foundation -)

  • 장석한;김희광;이강현;한경수;함방욱;정기선
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1031-1034
    • /
    • 2007
  • Electric transmission lines pass through a variety of area. Foundation supporting the conductors and tower are selected properly in accordance with external load, for example dead load, wind load, snow load, construction load etc, and topography and geology condition. Typical types of foundation are as follows: pad foundation for small load and hard soil or rock in mountainous area, pile foundation for medium or large load and soft soil in plain field area. This paper introduced cylindrical foundation design & construction for large load and mountainous area. This foundation failure mode against pulling-out show splitting failure by tensile force toward circumferential direction.

암반 앵커기초로 시공된 송전철탑 구조물의 거동특성에 관한 연구 (Behavior of Electric Transmission Tower with Rock Anchor Foundation)

  • 김경열;홍성연;이대수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.605-614
    • /
    • 2010
  • In this paper, the initial behavior of transmission tower was analyzed. This tower was firstly constructed by rock anchor foundation in domestic 154 kV transmission line and wireless real-time monitoring system was installed to obtain the measured data for analysis of the structure behavior. For this purpose, 16 strain gauges was installed in anchors of foundation and strain gauges, clinometers, anemoscope and settlement sensors was installed at superstructure. As the results, the main factor which influence the behavior of superstructure is wind velocity, wind direction, rainfall and temperature change. Especially, the uplift load at stub of transmission structure revealed about 35.4 percentages of design load. Hereafter the long term stability will be analyzed.

  • PDF

송전용 철탑기초의 현장수평재하시험을 통한 연결형 말뚝기초의 거동 및 지지력특성 (The Behavior and Resistance of Connected-pile Foundations for Transmission Tower from In-situ Lateral Load Tests)

  • 경두현;이준환;백규호;김대홍;김대학
    • 한국지반공학회논문집
    • /
    • 제28권2호
    • /
    • pp.57-70
    • /
    • 2012
  • 연약지반에 시공되는 송전철탑의 경우 말뚝기초가 주로 사용되나, 부등침하로 인한 철탑구조물의 손상이 유발될 수 있으며, 이에 따라 미국과 일본에서는 4각의 기초를 연결보로 연결한 연결형 기초의 사용을 추천하고 있다. 본 연구에서는 송전철탑에 작용하는 하중조건과 연결보의 강성조건이 연결형 말뚝기초의 수평거동에 미치는 영향을 조사하기 위해서 1/8 규모의 축소모델을 이용한 연결형 말뚝기초의 수평재하시험을 수행하였다. 본 시험결과 연결형 기초는 말뚝기초에 비하여 지지력이 크고 부등변위등의 송전철탑의 안전성을 저해하는 요인에 저항하는 효율적인 기초 형식인 것으로 나타났으며, 특히 연결보의 상대강성에 따른 효과를 분석한 결과 연결보의 강성이 매트의 강성대비 25%에서 연결형 기초의 형식으로 사용의 효율성이 좋은 것으로 나타났다.

Seismic responses of transmission tower-line system under coupled horizontal and tilt ground motion

  • Wei, Wenhui;Hu, Ying;Wang, Hao;Pi, YongLin
    • Earthquakes and Structures
    • /
    • 제17권6호
    • /
    • pp.635-647
    • /
    • 2019
  • Tests and theoretical studies for seismic responses of a transmission tower-line system under coupled horizontal and tilt (CHT) ground motion were conducted. The method of obtaining the tilt component from seismic motion was based on comparisons from the Fourier spectrum of uncorrected seismic waves. The collected data were then applied in testing and theoretical analysis. Taking an actual transmission tower-line system as the prototype, shaking table tests of the scale model of a single transmission tower and towers-line systems under horizontal, tilt, and CHT ground motions were carried out. Dynamic equations under CHT ground motion were also derived. The additional P-∆ effect caused by tilt motion was considered as an equivalent horizontal lateral force, and it was added into the equations as the excitation. Test results were compared with the theoretical analysis and indicated some useful conclusions. First, the shaking table test results are consistent with the theoretical analysis from improved dynamic equations and proved its correctness. Second, the tilt component of ground motion has great influence on the seismic response of the transmission tower-line system, and the additional P-∆effect caused by the foundation tilt, not only increases the seismic response of the transmission tower-line system, but also leads to a remarkable asymmetric displacement effect. Third, for the tower-line system, transmission lines under ground motion weaken the horizontal displacement and acceleration responses of transmission towers. This weakening effect of transmission lines to the main structure, however, will be decreased with consideration of tilt component.

수치해석을 이용한 송전철탑 연결형 기초의 연결보 강성에 따른 거동 특성 (Finite Element Analysis for Transmission Tower Behavior Characteristic by Connection Beam Stiffness)

  • 최영호;경두현;이준환
    • 대한토목학회논문집
    • /
    • 제33권1호
    • /
    • pp.219-227
    • /
    • 2013
  • 본 연구에서는 연약점토지반에 근입된 송전철탑 기초를 대상으로, 기초부보강공법의 하나인 연결형 기초 형식의 거동과 연결보 특성에 따른 성능발휘 효과를 분석하였다. 이를 위해 유한요소 해석 모델을 구축하였으며, 송전철탑 기초에 연결보의 매트와 닿는 면적비율변화에 의한 거동 및 저항력 특성을 분석하였고, 송전철탑 연결형 기초 모형실험 결과를 이용하여 구축된 유한요소 해석 모델의 타당성의 검증을 실시하여 다양한 매개변수 해석을 통해 연결보의 강성 증가에 따른 효과를 분석하여 송전철탑 연결형 기초의 거동에 효과적인 연결보의 강성을 선정 하였다. 또한, 연결보 자체 휨 모멘트 분포를 확인하여 취약부 분석을 실시하였다.