• Title/Summary/Keyword: Transmission method

Search Result 6,931, Processing Time 0.038 seconds

Using TRIZ about reduction gear noise in transmission (변속기 기어소음 저감을 위한 트리즈의 활용)

  • Heo, Tae-Hyuck;Yoo, Seung-Hyun;Han, Kyoung-Su;Jung, Ung-Rak;Heo, Kwon;Oh, Dae-Jin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1069-1074
    • /
    • 2007
  • TRIZ is innovative problem solving methodology. It can solve problems by systematical and convergent method, not by the existing divergent method like 'Brainstorming'. In this paper, TRIZ is used for reduction noise from gear in transmission. In order to reduce gear noise, design resources is derived first. According to the derived idea, level and function of system can be defined. After that, we suggest a way to reduce the noise from gear in transmission using 40 Principles and Substance-field analysis of TRIZ.

  • PDF

An Improved Dynamic Programming Approach to Economic Power Dispatch with Generator Constraints and Transmission Losses

  • Balamurugan, R.;Subramanian, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.320-330
    • /
    • 2008
  • This paper presents an improved dynamic programming (IDP) approach to solve the economic power dispatch problem including transmission losses in power systems. A detailed mathematical derivation of recursive dynamic programming approach for the economic power dispatch problem with transmission losses is presented. The transmission losses are augmented with the objective function using price factor. The generalized expression for optimal scheduling of thermal generating units derived in this article can be implemented for the solution of the economic power dispatch problem of a large-scale system. Six-unit, fifteen-unit, and forty-unit sample systems with non-linear characteristics of the generator, such as ramp-rate limits and prohibited operating zones are considered to illustrate the effectiveness of the proposed method. The proposed method results have been compared with the results of genetic algorithm and particle swarm optimization methods reported in the literature. Test results show that the proposed IDP approach can obtain a higher quality solution with better performance.

A study on the prediction method of the real fault distance using probability to the relay data of transmission line fault location (송전선로 거리표정치에 대한 실 고장거리의 확률적 예측방안)

  • Lee, Y.H.;Back, D.H.;Jang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.10-11
    • /
    • 2006
  • The fault location is obtained from the distance relay that detects the fault of the transmission line. In this time, transmission line crews track down the fault location and the reasons. However, because of having error at the fault location of the distance relay, there is a discordance between real and obtained fault location. As this reason, the inspection time for finding fault location can be longer. In this paper, we proposed the statistical (regression) analysis method based on each type of relay's the historical fault location data and the real fault distance data to improve the problems. With finding the regression equation based on the regression analysis, and putting the relay fault location into that equation, the real fault distance is calculated. As a result of the Prediction fault location, the inspection time of transmission line can be reduced.

  • PDF

Analysis of traveling wave antenna using rectangular microstip patch array (구형 마이크로스트립 패치 배열을 이용한 진행파 안테나의 특성 해석에 관한 연구)

  • 안광진;윤상원;장익수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.31-38
    • /
    • 1994
  • In this paper, the leaky wave readiation characteristics of a microstrip rectangular patch array is presented. The reflection and transmission characteristics are analyzed using the equivalent transmission line method. Since the leaky wave is generated from the periodic array, using the Floquet'theorem, leaky wave frequency range is predicted and confirmed by the measured reflection and transmission characterstics of the array. A 17 element microstrip patch array at X-Band is designed and tested. Teh scattering Characteristics show good agreement woth those obtained from the equivalent transmission line analysis. The radiatio characteristics at 10GHz using this method show about 3${\circ}$ shift in main lobe angle compared with measured results.

  • PDF

Effective Compensation of the Distorted 1.12 Tbps WDM Signals Using Optimization of Total Dispersion

  • Lee, Seong-Real
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.377-381
    • /
    • 2007
  • Nonlinear effects and chromatic dispersion are the main causes of pulse degradation in high bit-rate WDM transmission systems and several architectures have been proposed to compensate them by means of optical phase conjugation. In this paper, a new method to exploit an optical phase conjugator (OPC) for nonlinearity and dispersion cancellation is disclosed. The proposed method is using optimal total dispersion of each fiber sections and it is simpler than those previously described in literature. Power penalty between WDM channels and the maximum launch power in $28{\times}40$ Gbps WDM transmission system designed by optimal total dispersion are more decreased and more increased than those in the conventional WDM transmission system with OPC, respectively. Furthermore, optimal total dispersion proposed in this research should provide the flexible design of WDM system, which less depends on OPC position.

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI) (ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구)

  • Park Jae Hong;Lee Jong Beom
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

An Interference Avoidance Method Using Two Dimensional Genetic Algorithm for Multicarrier Communication Systems

  • Huynh, Chuyen Khoa;Lee, Won Cheol
    • Journal of Communications and Networks
    • /
    • v.15 no.5
    • /
    • pp.486-495
    • /
    • 2013
  • In this article, we suggest a two-dimensional genetic algorithm (GA) method that applies a cognitive radio (CR) decision engine which determines the optimal transmission parameters for multicarrier communication systems. Because a CR is capable of sensing the previous environmental communication information, CR decision engine plays the role of optimizing the individual transmission parameters. In order to obtain the allowable transmission power of multicarrier based CR system demands interference analysis a priori, for the sake of efficient optimization, a two-dimensionalGA structure is proposed in this paper which enhances the computational complexity. Combined with the fitness objective evaluation standard, we focus on two multi-objective optimization methods: The conventional GA applied with the multi-objective fitness approach and the non-dominated sorting GA with Pareto-optimal sorting fronts. After comparing the convergence performance of these algorithms, the transmission power of each subcarrier is proposed as non-interference emission with its optimal values in multicarrier based CR system.

An Analysis of the Eigenstructure and a New Design Method of Fault Detection Filters using Transmission Zeros (전달영점을 이용한 이상검출필터의 고유구조 해석 및 새로운 구성 방법)

  • Kim, Yong-Min;Park, Jae-Hong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1264-1271
    • /
    • 1999
  • In this paper, an efficient method of analysis and design of fault detection filter is presented. Since the directional constraint is applied to the eigenstructure associated with the detection space, an eigenvector is determined by the eigenvalues associated with other eigenvectors. Further, the assignment of a pair of eigenvalue and eigenvector leads to the fixation of overall eigenstructure related with the detection space. Using the transmission zeros and the transmission zero vectors, these phenomenon are clearly proven, and an efficient algorithm for design of the fault detection filters is presented.

  • PDF

Reduction Methods of Sheath Circulating Current in Underground Cable (지중 송전선로에서 시스 순환전류 저감 방안)

  • Ha, C.W.;Kim, J.N.;Lee, S.K.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.175-177
    • /
    • 2002
  • The use of underground transmission cables has increased continuously in densely inhabited urban and suburban for power transmission. Two or more transmission lines are outgoing from one substation in many cases, and one line comprises twin circuits. In order to meet the increasing do and for electric power, underground tables of two or fore circuits are installed in ducts in parallel for several kilometer in the same route. It, however, has not been known generally that the sheath circulating current is generated in a system where a large number of cables are laid on the same route. Therefore, this paper describes an improved analysis method for sheath circulating current on underground transmission cables using EMTP. Author propose several methods to reduce sheath circulating current. The analysing method and reduction methods for two or more underground cables will be really improved for cable system utility.

  • PDF

Reliability Evaluation of Transmission System using Monte Carlo Simulation Method (Monte Carlo Simulation기법을 이용한 송전계통의 신뢰도 평가)

  • Moon, Seung-Pil;Kim, Hong-Sik;Choi, Jae-Seok;Cha, Jun-Min
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.169-171
    • /
    • 2001
  • This paper presents a method fer evaluation nodal probabilistic congestion and reliability indices of transmission systems using Monte Carlo simulation methods. Quantitative evaluation of transmission system reliability is very important because successful operation of an electric power system. In the deregulated electricity market depends on transmission system reliability management Monte Carlo methods are often preferable, when complex operating conditions are involved and/or the number of sever events is relatively large. To evaluate the reliability of a real power system, Monte Carlo Methods will be more useful. The characteristics and effectiveness of this methodology are illustrated by the case study using a small test system.

  • PDF