Messaging System Analysis for Effective Embedded Tester Log Processing (효과적인 Embedded Tester Log 처리를 위한 Messaging System 분석)

  • Nam, Ki-ahn;Kwon, Oh-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.645-648
    • /
    • 2017
  • The existing embedded tester used TCP and shared file system for log processing. In addition, the existing processing method was treated as 1-N structure. This method wastes resources of the tester for exception handling. We implemented a log processing message layer that can be distributed by messaging system. And we compare the transmission method using the message layer and the transmission method using TCP and the shared file system. As a result of comparison, transmission using the message layer showed higher transmission bandwidth than TCP. In the CPU usage, the message layer showed lower efficiency than TCP, but showed no significant difference. It can be seen that the log processing using the message layer shows higher efficiency.

  • PDF

A Study on the Hazard Factor and Safety Management at Transmission Line During Live Line Works (송전선로 직접활선공법의 위험요인과 안전대책에 관한 연구)

  • Choi, Seung-Dong;Kang, Kyong-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.3
    • /
    • pp.51-66
    • /
    • 2006
  • This study was attempted to analyze risk factors and suggest accident prevention in live line works for power transmission lines to be developed and applied in Korea. Safety problem cannot but occur at development of live line works and application to the field. With respect to this, problems likely to occur in the field among works adopting methods of works including live line works for power transmission lines were investigated and analyzed through documentary survey and risk assessment method. The results are summarized as follows. A risk assessment method model was suggested. This method enables scientific and systematic development of safety control. That is, the owner may autonomously induce safety control and build risk assessment database by work process to use them as best training data for workers. Also, in the field, it may induce all workers to participate in safety program and secure safety by making workers seek for safety working method under smooth flow from looking at risk factors to accident prevention activities. It is deemed that this humble study will prevent both accident and injury likely to occur in live line works for power transmission lines.

Object Regions Prior Transmission Method Using Bidirectional Round fitter (양방향 반올림 필터를 이용한 객체 영역 우선 전송 기법)

  • 강경원;문광석
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.4
    • /
    • pp.1-6
    • /
    • 2002
  • Generally, most significant information of images is included in the object regions. Thus, this paper proposes the object regions prior transmission method using the bidirectional round filter. The proposed method extracts the object regions, and then transmits the wavelet coefficients of the object regions, prior to others, in the encoding procedure using SPIHT So, it makes significant image information be restored faster than others for a short time. Consequently, through the proposed method the significant information of images is able to be recognized at a low bit rate and the condition of the continuous transmission is decidable by recognizing significant information fast, so that the searching time and efficiency can be improved.

  • PDF

Spectral element method in the analysis of vibrations of overhead transmission line in damping environment

  • Dutkiewicz, Maciej;Machado, Marcela
    • Structural Engineering and Mechanics
    • /
    • v.71 no.3
    • /
    • pp.291-303
    • /
    • 2019
  • In the paper the analysis of natural vibrations of the transmission line with use of spectral elements and the laboratory experiments is performed. The purpose of the investigation is to analyze the natural vibrations of the transmission line and compare with the results obtained in the numerical simulations. Particular attention is paid to the hysteretic and aerodynamic damping analysis. Sensitivity of the wave number is performed for changing of the tension force, as well as for the different damping parameters. The numerical model is made using the Spectral Element Method. In the spectral model, for various parameters of stiffness, damping and tension force, the system response is checked and compared with the results of the accelerations obtained in the measurements. A frequency response functions (FRF) are calculated. The credibility of the model is assessed through a validation process carried out by comparing graphical plots of FRF and time history analysis and numerical values expressing differences in acceleration amplitude (MSG), phase angle differences (PSG) and differences in acceleration and phase angle total (CSG) values. The next aspect constituting the purpose of this paper is to present the wide possibilities of modelling and simulation of slender conductors using the Spectral Element Method. The obtained results show good accuracy in the range of both experimental measurements as well as simulation analysis. The paper emphasizes the ease with which the sensitivity of the conductor and its response to changes in density of spectral mesh division, tensile strength or material damping can be studied.

A Study on the Configuration Method of CCPU for Lightning Surge in Underground Transmission System (지중송전계통의 방식층 보호장치 결선방식에 대한 뇌써어지 해석)

  • Kim, Dae-Kyeong;Jeong, Seong-Hwan;Lee, Jong-Bum;Kim, Jeom-Shik
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1018-1020
    • /
    • 1997
  • This paper is compared the configuration method of cable cover protection unit with respect to the lightning surge in 154kV underground transmission system. There are many methods of connecting CCPU, i.e, a conventional method, CIGRE method, inter-connection between sheath with grounding, and interconnection between sheath without grounding.

  • PDF

A Stability Estimation Method of Subspan Oscillation on Overhead Transmission Lines (가공송전선로의 서브스판 진동에 대한 안정성 평가기법)

  • Sohn, Hong-Kwan;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.522-524
    • /
    • 2003
  • This paper presents a stability estimation method for subspan oscillation on overhead transmission line. It has been used method by conductor's fatigue limit or subspan oscillation amplitude. But it is not proper to estimation of subspan oscillation. We suggest to instability index for estimation method of subspan oscillation. And we tried to 4 bundled conductor system. This result will use to establish of the subspan location rules.

  • PDF

Effective Transmission Method using Energy Efficient Adaptive Modulation (에너지 효율과 적응변조를 이용한 이동통신 시스템의 효율적인 데이터 전송방법)

  • Oh, Eyu-Kyo
    • Journal of Digital Convergence
    • /
    • v.10 no.9
    • /
    • pp.369-374
    • /
    • 2012
  • In this paper, the effective transmission method is proposed to save the energy and to increase the throughput of the communication system using adaptive modulation. Traditionally, adaptive modulation has been used to improve the throughput using the power margin of the system design. Considering the instantaneous energy during the modulation method changing duration, the effective transmission method is proposed. By the simulation, the performance and effectiveness is validated.

Variational Image Dehazing using a Fuzzy Membership Function

  • Park, Hasil;Park, Jinho;Kim, Heegwang;Paik, Joonki
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.2
    • /
    • pp.85-92
    • /
    • 2017
  • This paper presents a dehazing method based on a fuzzy membership function and variational method. The proposed algorithm consists of three steps: i) estimate transmission through a pixel-based operation using a fuzzy membership function, ii) refine the transmission using an L1-norm-based regularization method, and iii) obtain the result of haze removal based on a hazy image formation model using the refined transmission. In order to prevent color distortion of the sky region seen in conventional methods, we use a trapezoid-type fuzzy membership function. The proposed method acquires high-quality images without halo artifacts and loss of color contrast.

Analysis of the Sound Radiation of Transmission Gearbox Housing and Reduction Design (변속기 케이스에서 발생하는 방사소음 해석 및 저감 설계)

  • Jeong, Seong-Young;Oh, Ha-Yeong;Park, Jun-Hong;Park, Gyung-Jin;Lee, Hyun-Ah;Choi, Joong-Sun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.6
    • /
    • pp.521-527
    • /
    • 2010
  • This article presents a method to calculate the sound radiation of transmission gearbox housing by using Helmholtz integral. Rayleigh integral is used to verify the method. Half-space radiation is considered because the actual gearbox housing is on hard place like concrete. For optimization, orthogonal array is used as a fractional factorial design method. Sound Radiation is calculated with simple source like plate and sphere shape, then actual gearbox BEM model is applied to the method.

The Coupling Analysis of Electromagnetic Wave to Transmission Line using Nonhomogeneous Differential Equations (비동차 미분방정식을 이용한 외부 전자파에 의한 전송선로 결합해석)

  • 이기철;명성호
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.1 no.1
    • /
    • pp.20-27
    • /
    • 1990
  • This paper presents an efficient method to estimate the induced current by the external electromagnetic wave when the line system is composed of cascaded transmission lines. To solve this phenomena, we apply the state variable method to the nonhomogeneous differential equation. This new method is the way of transferring the sources at a different point by the Ch- aracteristics of the transition matrix. Using this method, we investigate the characteristics of the induced power of the transmission line above the perfectly conducting ground plane.

  • PDF