• Title/Summary/Keyword: Transmission Line Method

Search Result 1,067, Processing Time 0.027 seconds

Compensation Characteristics of Distorted Channels in 200 Gbps WDM Systems using Mid-Span Spectral Inversion Method (200 Gbps WDM 시스템에서 Mid-Span Spectral Inversion 기법을 이용한 채널 왜곡의 보상 특성)

  • 이성렬
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.845-854
    • /
    • 2003
  • In this paper, the characteristics of compensation for WDM channel signal distortion due to both chromatic dispersion and Ken effect in 1,000 km 200 Gbps(5${\times}$40 Gbps) WDM systems was investigated. The WDM system has a path-averaged intensity approximation(PAIA) mid-span spectral inversion(MSSI) as a compensation method. This system has a highly nonlinear dispersion shifted fiber(HNL-DSF) optical phase conjugator(OPC) in the mid-way of transmission line. In order to evaluate the degree of compensation, 1 dB eye opening penalty(EOP), bit error rate(BER) characteristics and power penalty of 10$\^$-9/ BER are used. It is confirmed that HNL-DSF is an useful nonlinear medium in OPC fur wideband WDM system with PAIA MSSI and that the optimal compensation for WDM channel distortion is achieved by the selection of pump light power of OPC, which equalize the conjugated light power into the second half fiber section with the input WDM signal light power depending on total transmission length, dispersion coefficient of fiber, OPC pump light wavelength, conversion efficiency of WDM channel in OPC.

The study on the effect of fracture zone and its orientation on the behavior of shield TBM cable tunnel (단층파쇄대 규모 및 조우 조건에 따른 전력구 쉴드 TBM 터널의 거동 특성 분석)

  • Cho, Won-Sub;Song, Ki-Il;Kim, Kyoung-Yul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.403-415
    • /
    • 2014
  • Recently, the temperature rise in the summer due to climate change, power usage is increasing rapidly. As a result, power generation facilities have been newly completed and the need for ultra-high-voltage transmission line for power transmission of electricity to the urban area has increased. The mechanized tunnelling method using a shield TBM have an advantage that it can minimize vibrations transmitted to the ground and ground subsidence as compared with the conventional tunnelling method. Despite the popularity of shield TBM for cable tunnel construction, study on the mechanical behavior of cable tunnel driven by shield TBM is insufficient. Thus, in this study, the effect of fractured zone ahead of tunnel face on the mechanical behavior of the shield TBM cable tunnel is investigated. In addition, it is intended to compare the behavior characteristics of the fractured zone with continuous model and applying the interface elements. Tunnelling with shield TBM is simulated using 3D FEM. According to the change of the direction and magnitude of the fractured zone, Sectional forces such as axial force, shear force and bending moment are monitored and vertical displacement at the ground surface is measured. Based on the stability analysis with the results obtained from the numerical analysis, it is possible to predict fractured zone ahead of the shield TBM and ensure the stability of the tunnel structure.

An Improved Monte-Carlo Simulation Method for Typhoon Risk Assessment in Korea (개선(改善)된 Monte-Carlo 시뮬레이션 방법(方法)에 의한 한국(韓國)의 태풍위험도(颱風危險度) 분석(分析))

  • Cho, Hyo Nam;Chang, Dong Il;Cha, Cheol Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.4
    • /
    • pp.159-165
    • /
    • 1987
  • This study proposes an operational method of typhoon risk assessments in Korea, using Statistical analysis and probabilistic description of typhoon at a site. Two alternative simulation and fitting methods are discussed to predict the probabilistic typhoon wind speeds by indirect methods. A Commonly used indirect method is Russell's procedure, which generates about 1,000 Simulation data for typhoon winds, statistically evaluate the base-line distribution, and then fits the results to the Weibull distribution based on probabilistic description of climatological Characteristics and Wind field model of typhoon at a site. However, an alternative procedure proposed in this Paper simulates extreme typhoon wind data of about 150~200 years and directly fits the generated data to the Weibull distribution. The computational results show that the proposed simulation method is more economical and reasonable for typhoon risk-assessment based on the indirect method. And using the proposed indirect method, the probabilistic design wind speed for transmission towers in typhoon-prone region along the South-Western coast is investigated.

  • PDF

Power Factor Compensation System based on Voltage-controlled Method for 3-phase 4-wire Power System (3상 4선식 전력계통에서 전압제어 방식의 역률보상시스템)

  • Park, Chul-woo;Lee, Hyun-woo;Park, Young-kyun;Joung, Sanghyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.107-114
    • /
    • 2017
  • In this paper, a novel power factor compensation system based on voltage-controlled method is proposed for 3-phase 4-wire power system. The proposed voltage-controlled power factor compensation system generates a reactive power required for compensation by applying a variable output voltage by a slidac to a capacitor. In conventional power factor compensation system using the capacitor bank method, the power factor compensation error occurs depending on the load condition due to the limited capacity of the capacitors. However, the proposed system compensates the power factor up to 100% without error. In this paper, we have developed a voltage-controlled power factor compensation system and a control algorithm for 3-phase 4-wire power system, and verify its performance through simulation and experiments. If the proposed power factor compensation system is applied to an industrial field, a power factor compensation performance can be maximized. As a result, it is possible to reduce of electricity prices, reduce of line loss, increase of load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Feasibility of Coculture Method for Production of Chimeric Mice Using J1 Embryonic Stem Cells

  • Shin Hye-Jun;Park Sung-Sik;Kim Sun-Uk;Cho Sang-Mi;Han Ying-Hao;Kim Hyun-Sun;Kim Sang-Geun;Lee Dong-Seok;Yu Dae-Yeul
    • Biomedical Science Letters
    • /
    • v.10 no.4
    • /
    • pp.391-395
    • /
    • 2004
  • The demand for the production of gene-defective mice from embryonic stem (ES) cells is increasing to clarify decisive gene function in vivo. Although blastocyst injection is widely used to generate ES cell-mediated knockout mice, coculture method has been alternatively used because of several advantages, such as low cost and simple procedure. Thus, this experiment was designed to demonstrate the feasibility of the coculture method using J1 ES cells, which are known to be efficient for blastocyst injection. Eight-cell embryos were harvested from 2.5 days post-coitum (dpc), denuded with acid tyrode's solution, and transferred onto trypsinized J1 ES cells. Aggregation was carried out following two typical methods, which are simple coculture method and aggregation in groove prepared by aggregation needle. Successfully aggregated-embryos were developed to blastocysts for 24 h and transferred into uterus of pseudo-pregnant foster mother. Chimeric offspring was judged by coat pigmentation. In this study, we could obtain chimeric mice from all the two aggregation methods, but the chimera production efficiencies in coculture using groove were three times higher at least than those in the other group. In conclusion, these observations suggest that coculture method should be available for production of knockout mice from J1 ES cells. Presently, the germ-line transmission rates of the chimeras produced from the two methods are under investigation.

  • PDF

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

A Study of Broadband Propagation Characteristics for The Future Mobile Communications (II) - The Improvement of Broadband Propagation Characteristics using Polarization Diversity under Indoor Environment (차세대 이동통신에서의 광대역 전파특성 연구(II) - 편파 다이버시티를 이용한 실내에서의 광대역 전파특성 개선-)

  • 하덕호;윤영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.78-89
    • /
    • 1999
  • In this paper, to improve bandwidth amplitude fluctuation for the broadband signal in indoor propagation environment, we measured and analyzed broadband signal using a vertically polarized, horizontally polarized and circularly polarized antenna, conducting by frequency sweeping method in NLOS (Non-Line-of-Sight) environment. And, to investigate the optimum condition for the improvement of broadband propagation characteristics we also examined the effects of both human motions and transmission antenna height in the NLOS environment. As a result, in the case of NLOS environment, it was found that the amplitude deviation characteristics in frequency bandwidth can be improved by polarization diversity reception. Especially, we found that it is the best effective one to make polarization diversity reception branches, which install the circularly polarized antenna at transmitting end and install the polarized diversity branches received vertical or/and horizontal polarized wave at receiving end. The affection of a human motions is not so much in LOS and NLOS environment, but it can lead to the cause of burst error in indoor digital radio communications as the fade of signal strength become more deeper. And also, when raise the transmitting antenna up to the ceiling, the LOS and NLOS environment could be coexisted. In this case, it can be also inferred that frequency bandwidth amplitude deviation must be fundamentally improved by using polarization diversity reception technique to make the possibility of high transmission rate.

  • PDF

A Quasi-nonlinear Numerical Analysis Considering the Variable Membrane Tension of Vertical Membrane Breakwaters (연직 막체방파제의 변동 막체장력을 고려한 준 비선형 수치해석)

  • Chun, In-Suk;Kim, Sun-Sin;Park, Hyun-Ju
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.4
    • /
    • pp.290-300
    • /
    • 2009
  • The existing numerical methods on the vertical membrane breakwater have employed a linear analysis where the variable membrane tension occurring during membrane motions is assumed to be very negligible compared to the initial tension. In the present study, a quasi-nonlinear analysis is attempted such that the temporary tension of the membrane is substituted by the average tension for a wave period that is sought by an iterative calculation. The results showed that with the increase of the wave period the reflection coefficients appeared larger and the transmission coefficients smaller compared to the results of the linear analysis. The application of the quasi-nonlinear analysis also showed that the performance of the structure is closely dependent on the horizontal deformation of the membrane. In order to suppress the horizontal deformation, it may be required to take the larger initial tension of the membrane or to put additional mooring lines in the middle of the vertical faces of the membrane. But for theses methods to be effective, a largely sized surface float should be installed to secure enough buoyancy to support such downward forces.

Experimental Study of the Effect of Shortening of Life of Tapered Roller Bearings when Subjected to Excessive Axial Pre-Load (과다 예압을 받는 테이퍼롤러 베어링의 수명단축효과에 대한 실험적 연구)

  • Park, Jong-Won;Kim, Hyoung-Eui;Kim, Jong-Ock;Sim, Yang-Jin;Jung, Won-Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1161-1166
    • /
    • 2010
  • Tapered roller bearings are core components of rotating machine parts and are simultaneously subjected to axial and radial loads. Life-shortening effect was particularly evident in the case of tapered roller bearings used in the input and output shafts of transmission; this shortening of life was a result of excessive axial pre-load, which is common in the transmission assembly line. In this study, we derived an equation for evaluating the life of tapered roller bearings subjected to excessive pre-load by using accelerated life test data. The DOE(Design Of Experiment) method and FEA(Finite Element Analysis) was used for determining the condition for performing an accelerated life test. This equation for evaluating the service life of the bearings was derived by analyzing the Weibull distribution of the test results. Using the derived equation the life evaluated was 6-7 times longer than that evaluated by the conventional $L_{10}$ bearing-life equation. The results of this study will be helpful in predicting the life of tapered roller bearings subjected to excessive pre-load and in designing reliable rotating machines.

Low Resistivity Ohmic Co/Si/Ti Contacts to P-type 4H-SiC (Co/Si/Ti P형 4H-SiC 오옴성 접합에서 낮은 접촉 저항에 관한 연구)

  • Yang, S.J.;Lee, J.H.;Nho, I.H.;Kim, C.K.;Cho, N.I.;Jung, K.H.;Kim, E.D.;Kim, N.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.112-114
    • /
    • 2001
  • In this letter, we report on the investigation of Si/Ti, Pt/Si/Ti, Co/Si/Ti Ohmic contacts to p-type 4H-SiC. The contacts were formed by a 2-step vacuum annealing at $550^{\circ}C$ for 5 min, $850^{\circ}C$ for 2 min respectively. The contact resistances were measured using the transmission line model method, which resulted in specific $10^{-4}{\Omega}cm^2$, and the physical properties of the contactcontact resistivities in the $9.2{\times}10^{-4}$, $7.1{\times}10^{-4}$ and $4.5{\times}s$ were examined using microscopy, AES(auger electron spectroscopy). AES analysis has shown that, at this anneal temperature, there was a intermixing of the Ti and Si, migration of into SiC. Overlayer of Pt, Co had the effect of decreasing the specific contact resistivity and improving the surface morphology of the annealed contact.

  • PDF