• Title/Summary/Keyword: Transient phenomenon

Search Result 251, Processing Time 0.022 seconds

A Study on the Transient Phenomenon Protection System Development for Fire Alarm System Control Unit (화재 수신기용 과도현상 보호시스템 개발에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.55-61
    • /
    • 2009
  • This study has been carried on the transient phenomenon protection system to become fire alarm system control unit of high reliance which can be protected from transient phenomena for surge or transient overvoltage, and constructed engineering base that can develop transient phenomenon protection system by proving performance of protection system in a experimental. This study developed 1 step and 2 step protection system that can be protected from transient phenomenon with process thesis and theory for development of transient phenomenon protection system. It established engineering data construction and a source technology that can develop transient phenomenon protection system as gets satisfied result and test with all performance condition that present in fire protection law and connection regulation.

An Analysis on the Vibration Characteristic of a Automobile at the Sudden Change of an Accelerator under Traveling (주행중 가속페달의 급조작시 승용차의 진동특성 해석)

  • 홍동표;정태진;김상수;태신호
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.353-363
    • /
    • 1994
  • The non-preiodic fluctuation of the engine torque appears to be the major source of the torsional vibration of the automotive driveline. The reduction of this torsional vibration hs become a significant problem along with the requirements of higher performance. The shuffle(tip-in, tip-out) is the transient vibration phenomenon of a vehicle which appears at the sudden change of an accelerator under traveling. By executing of an experiment and a simulation using a model, it has become possible to obtain the design parameter of a driveline for the torsional vibration. This paper presents an experimental and theoretical research on the transient vibration phenomenon of a vehicle which appears at the sudden change of an accelerator under traveling. A dynamic model for the automotive driveline was developed, and all parameters of the mmdel were evaluated with experimental data. The results are as follows: (1) The lower the gea ratio of the transmission is, the more the transient vibration phenomenon of a vehicle appears clearly. (2) The transient vibration phenomenon of a vehicle is affected by the design parmeter of the driveline.

  • PDF

Verification of Underground Distribution Line Modeling with Field Test (실증시험을 통한 지중배전선로 모델링 기법 검증 연구)

  • Yun, Chang-Sub;Lee, Jae-Bong;Kim, Byong-Suk;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2091-2097
    • /
    • 2007
  • This paper described the verification of modeling technique of underground distribution from comparison between field test and simulation. It needs more exact transient phenomenon analysis model to establish lightning protection of underground distribution line. Although, there were a lot of transient phenomenon researches, nobody could has verified the confidence of modeling from field tests in interior until now. So, simulation model verified field test is needed to analyse transient phenomenon of underground distribution system. The examination must be accomplished in many different condition before suggesting these verified analysis model. In this paper, the conditions were examined and the various data results on the different line composition was compared with the EMTP simulation, when the lightning impulse test was accomplished at underground distribution line. Also the value between field test and simulation was very closed and the method of modeling has demonstrated confidence, when the method is used to analyse domestic transient phenomenon of underground distribution.

A Study on Torque and Speed Control of Three Phase Induction Motor (3상(相) 유도전동기(誘導電動機)의 토크 및 속도제어(速度制御)에 관한 연구(硏究))

  • Choi, K.H.;Jeong, S.K.;Yang, J.H.
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.7 no.1
    • /
    • pp.111-126
    • /
    • 1995
  • In general, the electromagnetic transient phenomenon always exists in induction motor(IM) with the torque change. The control performance of IM is very worse than that of D.C motor owing to this transient phenomenon. So many studies about the elimination methods of the transient phenomenon have been making progress. Interesting methods of them are the Field acceleration method(FAM) and the method of impulse addition on the input voltage at the time point of torque change. In this paper, first, the circuit equation of IM is derived from the phase segregation method. The torque equation consisted of the stator and rotor currents is derived from the solving of the circuit equation. As we well known, the transient terms exist in this the torque equation. The method of impulse addition on the input voltage at the instance of torque change is confirmed theoretically for the elimination of the transient phenomenon. With the base on it, the author proposed a real time algorithm to eliminate the transient terms. The control system is consisted of the PI controller with the feedforward of torque change. The author could confirm that the quick stepwise responses of torque and speed can be obtained from response simulations.

  • PDF

A Study on the Performance Transient Phenomenon at the Interface of a Dual Thrust Rocket Motor with Two Kinds Propellant (이종 추진제를 적용한 이중추력 로켓모터 계면에서의 성능 과도 현상에 관한 연구)

  • Kim, Kyungmoo;Lee, Kiyeon;Kim, Jeongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.2
    • /
    • pp.79-87
    • /
    • 2021
  • In this study, we developed a method to predict/analyze the performance of a dual thrust rocket motor that has 2 kinds propellant charged in axial direction. When transitioning from the booster to the suspender stage, a transient phenomenon related to performance occurred at the interface. The causes and characteristics of the transient phenomenon were investigated by comparing them with the results of the combustion test. It was confirmed that the performance transient phenomenon is sensitively generated not only by the shape design between the propellants with different properties of the propellant, but also by errors in manufacturing due to the propellant curing shrinkage.

Experimental Study of The Floating-Phenomenon on Neutral Ungrounded UPS System (중성점 비접지 UPS시스템의 부동현상에대한 실험적 연구)

  • Shim, Hae-Sup
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.67-72
    • /
    • 2011
  • In this study we investigate the background of UPS output transformer(${\Delta}-Y$) operation on neutral ungrounded system, and perform field experiment of neutral floating-phenomenon for the inter-locked securing of electric facilities and improvement of neutral floating-phenomenon. Experiment results show that a floating-phenomenon occurs when four-pole input-breaker trip and the neutral to earth voltage occurring concurrently is identified as phantom voltage. And the measures for the transient overvoltage that can occur in floating-state also are investigated. As a result, the risk elements of neutral ungrounded method as well as neutral floating-phenomenon are removed by installation of separate solidly-grounded transformer and switching four-pole input-breaker to three-pole input breaker.

An Analysis and Assessment of Transient Vibration Phenomenon for Precision Equipment Due to Adjacent Utility Operation in TFT-LCD Fab (TFT-LCD 생산공장 내 유틸리티 가동으로 인한 정밀장비 과도진동 현상 및 평가)

  • Baek, Jae-Ho;Lee, Hong-Ki;Son, Sung-Wan;Chun, Chong-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.8
    • /
    • pp.726-735
    • /
    • 2007
  • Inside the factory buildings of aprecision industry (which produces semiconductors or TFT-LCD), thousands of vibration-sensitive precision equipments operate in the clean rooms. Various utility equipments that are installed around them for proper operation cause various sources of noise and of vibration to exist inside the clean rooms and thus deteriorate the noise and the vibration environment within. In this study, we check if the existing transient vibration phenomenon is caused by the vibrations that arise from operating the utility installed near these equipments; compare and evaluate the vibration criteria of precision equipments regarding the transient vibration phenomenon; and check the efficiency of these criteria.

A Study on the Transient Phenomenon Analysis of Ship Generator Synchronization (선박용 발전기 동기화시의 과도현상 해석에 관한 연구)

  • Oh, Sae-Gin;Kim, Jong-Su;Kim, Sung-Hwan;Lee, Sung-Gun;Jo, Sung-Kab
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.998-1004
    • /
    • 2007
  • Connecting a synchronous generator to a power system is a dynamic process, requiring the coordinated operation of many components and systems. The goal is to connect the oncoming generator to the system smoothly i.e without causing any significant bumps, surges, or power swings, by closing the ACB when the oncoming generator matches the power system in voltage magnitude, phase angle, and frequency. If oncoming generator voltage is not matched to the power system voltage, reactive power will flow either into or out of the system at the instant of ACB closure. If this voltage difference is too great, the reactive power flow may result in high transient stresses that could damage the windings of the generator. Also, if oncoming generator frequency is not matched to the power system frequency, transient power will flow between generator and power system. If the frequency difference is too great, the transient power flow is reflected into the prime mover shaft, and this may result in excessive shaft or coupling stress. This paper tries to prove the necessity of correct synchronization for ship generators through a transient phenomenon analysis.

A Study on the Transient Phenomenon Analysis at the instant of Parallel Running for A.C. Generators (교류발전기 병렬운전시 과도현상 해석에 관한 연구)

  • 오세진;김현수;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1065-1075
    • /
    • 2001
  • It is common knowledge amongst electrical and marine engineers that short-circuit in electrical system may cause large mechanical torque on generator and prime mover However, it is not so widely known that the faulty synchronizing of generators may cause even higher torques than that of short-circuit. In this study, the transient phenomena related to the parallel running of synchronous generators are analyzed and the exact computer simulation method is proposed. In result, maximum transient torque and current take place in case of $120^{\circ}$ voltage angle difference between Master and Slave and that may develop higher torque than the short-circuit according to a condition of synchronizing. When synchronizing in power system using only two generators higher torque and current occur Master, but using multimachine system those occur to Slave. The short-circuit of marine generator does not happen frequently but faulty synchronizing sometimes takes place, therefore, it is necessary for designers to consider these phenomena.

  • PDF

Hysteric Transient Phenomenon of Under-Expanded Moist Air Jets (부족팽창 습공기 제트의 히스테리과도현상)

  • Oh, S.J.;Shin, C.S.;Kim, H.D.;Setoguchi, T.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.460-463
    • /
    • 2008
  • the present study, the addresses the hysteric phenomenon of under-expanded jets with a help of a computational fluid dynamics methods. The under-expanded jets of both dry and moist air have been employed to the transient processes for the pressure ratio. It is known that under-expanded air jet produced during the process of increase in pressure ratio behaves different from the reducing process, leading to a hysteric phenomenon of under-expanded jet. It is also known that moist air jet significantly reduces the hysteric phenomenon found in the dry air jet, and that non-equilibrium condensation which occurs in the under-expanded moist air jet is responsible for these findings.

  • PDF