• 제목/요약/키워드: Transient noise

검색결과 400건 처리시간 0.021초

주행중 가속페달의 급조작시 승용차의 진동특성 해석 (An Analysis on the Vibration Characteristic of a Automobile at the Sudden Change of an Accelerator under Traveling)

  • 홍동표;정태진;김상수;태신호
    • 소음진동
    • /
    • 제4권3호
    • /
    • pp.353-363
    • /
    • 1994
  • The non-preiodic fluctuation of the engine torque appears to be the major source of the torsional vibration of the automotive driveline. The reduction of this torsional vibration hs become a significant problem along with the requirements of higher performance. The shuffle(tip-in, tip-out) is the transient vibration phenomenon of a vehicle which appears at the sudden change of an accelerator under traveling. By executing of an experiment and a simulation using a model, it has become possible to obtain the design parameter of a driveline for the torsional vibration. This paper presents an experimental and theoretical research on the transient vibration phenomenon of a vehicle which appears at the sudden change of an accelerator under traveling. A dynamic model for the automotive driveline was developed, and all parameters of the mmdel were evaluated with experimental data. The results are as follows: (1) The lower the gea ratio of the transmission is, the more the transient vibration phenomenon of a vehicle appears clearly. (2) The transient vibration phenomenon of a vehicle is affected by the design parmeter of the driveline.

  • PDF

유한요소법을 이용한 종형 구조물의 동적거동 및 음향거동에 관한 연구 (A Study on Dynamic and Acoustic Behavior of Beel Type Structure Using Finite Element Method)

  • 정석주
    • 소음진동
    • /
    • 제6권4호
    • /
    • pp.447-456
    • /
    • 1996
  • Dynamic characteristics of the bell-type structure including acoustic effects and transient dynamic problems were analyzed numerically. Natural frequencies, mode shapes and transient dynamic analysis used the finite element method with 3-D general shell element. Mode shapes and stress distributions of transient dynamic analysis were expressed by computer graphics. The method using this study was evaluated by comparision of theoretical results at reference papers(14), (15) and the experimental test using Fast Fourier Transform analyzer. Vibrational modes governing acoustic characteristics of the typical bell-type structure depended on the first flexural mode(4-0 mode) and the second flexural mode(6-0 mode). Asymmetric effects by Dangiwas, acoustic holes gave rise to beat frequencies, and the Dangjwa was found to be most effective. When impact load acted on the bell, stress concentration occured at the rim part of bell. It was found that the bell type structure should be designed thickly at the rim part in order to prevent impact load from stress concentration.

  • PDF

LTE 상향 링크 시스템에서 송신기의 전력 과도 현상에 의해 발생하는 ICI를 제거하기 위한 적응적 멀티 탭 등화 기법 (Adaptive Multi-Tap Equalization for Removing ICI Caused by Transmitter Power Transient in LTE Uplink System)

  • 채혁진;조일남;김동구
    • 한국전자파학회논문지
    • /
    • 제20권8호
    • /
    • pp.701-713
    • /
    • 2009
  • 본 논문은 LTE 상향 링크 전송에서 물리적 채널간의 전력 과도 현상으로 인한 인접 부 반송파 간섭으로 반송파간의 직교성이 손상되어 수신 신호에 성능감쇄를 초래하는 문제점을 개선하기 위한 기법을 연구하였다. 전력과도 현상에 의해 발생하는 인접 부 반송파 간섭은 도플러 효과에 의해 발생하는 인접 부 반송파 간섭과는 다른 형태로 채널의 전후에서 전력 변화의 각 주기마다 발생한다. 인접 부 반송파 간섭이 발생하는 원인은 채널간의 전력 차이, 전력 과도 구간의 길이, 다중경로 채널 지연 스프레드 그리고 부 반송파의 수에 의해서 발생한다. 본 논문에서는 위에 언급한 4가지 원인으로 인해 발생하는 인접 부 반송파 간섭을 개선하기 위한, 각 채널별 다중 탭 등화기의 탭 수를 결정하는 새로운 기법을 제시하였다. 이 기법은 정규화된 간섭(normalized interference) 즉, 정규화된 부 반송파간의 간섭이 정규화된 잡음(normalized noise)보다 클 때 다중 탭 등화기의 탭 수를 결정하는 기법이다. 모의 실험 결과에서, 수신 신호의 SNR에 따라 적응적으로 탭 수가 조절되고 비트 오류율(BER)의 성능이 향상 됨을 보였고 또한 제안한 기법의 복잡도가 전통적인(classical) 방법의 복잡도 보다 88 % 줄어듦을 보였다.

통합제진마운트용 MR 댐퍼의 실험적 성능 평가 (Experimental Performance Evaluation of MR Damper for Integrated Isolation Mount)

  • 성민상;최승복;김철호;이홍기;백재호;한현희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.65-70
    • /
    • 2010
  • This paper presents experimental performance evaluation of a magnetorheological (MR) damper for integrated isolation mount for ultra-precision manufacturing system. The vibration sources of the ultra-precision manufacturing system can be classified as follows: the one is the environmental vibration from the floor and the other is the transient vibration occurred from stage moving. The transient vibration occurred from the stage moving has serious adverse effect to the process because the vibration scale is quite larger than other vibrations. Therefore in this research, a semi-active MR damper, which can control the transient vibration, is adopted. Also the stage needs to be isolated from tiny vibrations from the floor. For this purpose, a dry-frictionless MR damper is required. In order to achieve this goal, a novel type of MR damper is originally designed and manufactured in this work. Subsequently, the damping force characteristics of MR damper are evaluated by simulation and experiment. In addition, the vibration control performance of the MR damper associated with the stage mass is evaluated.

  • PDF

자이로스코프 시스템을 이용한 드럼 세탁기의 진동 저감 연구 (A Study on Reducing Vibration of Washing Machine Using Gyroscope System)

  • 나규성;박영진;박윤식
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.117-122
    • /
    • 2014
  • A novel method to reduce the vibration of drum type washing machine is proposed. Recently, as the capacity of the drum-type washing machine gets expanded and its washing performance is improved, its market share is increasing in the whole world. But, the capacity of washing machine is limited because of door size and built-in washing machine size. The vibration of washing machine is caused by unbalanced cloths in high spining drum, and the displacement of tub is maximized at transient range about 3 Hz(180 rpm). Previous researches were concerned about steady-state vibration in spinning. In this study, concerned about transient vibration and the displacement of tub is decreased by using gyroscope system. Mutibody dynamic model of washing machine include gyroscope is designed and the vibration of tub have been reduced by 44.7 % over original.

통합제진마운트용 MR 댐퍼의 실험적 성능 평가 (Experimental Performance Evaluation of MR Damper for Integrated Isolation Mount)

  • 성민상;최승복;김철호;이홍기;백재호;한현희;우제관
    • 한국소음진동공학회논문집
    • /
    • 제20권12호
    • /
    • pp.1161-1167
    • /
    • 2010
  • This paper presents experimental performance evaluation of a magnetorheological(MR) damper for integrated isolation mount for ultra-precision manufacturing system. The vibration sources of the ultra-precision manufacturing system can be classified as follows: the one is the environmental vibration from the floor and the other is the transient vibration occurred from stage moving. The transient vibration occurred from the stage moving has serious adverse effect to the process because the vibration scale is quite larger than other vibrations. Therefore in this research, a semi-active MR damper, which can control the transient vibration, is adopted. Also the stage needs to be isolated from tiny vibrations from the floor. For this purpose, a dry-frictionless MR damper is required. In order to achieve this goal, a novel type of MR damper is originally designed and manufactured in this work. Subsequently, the damping force characteristics of MR damper are evaluated by simulation and experiment. In addition, the vibration control performance of the MR damper associated with the stage mass is evaluated.

공기조화기 축류팬의 공력소음 특성 연구 (The Study on the Aeroacoustic Characteristics of an Axial Fan for an Air-Conditioner)

  • 이수영;한재오;김태헌;이재권;전완호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2006
  • This paper proposes a new computational aeroacoustics method for an axial fan analysis. The major aeroacoustic noise source of an outdoor air-conditioner is the axial fan. It was revealed that the dominant noise source is the aerodynamic interactions between the rotating blade and stationary orifice. Many researches were focused on the fan only case. However, it does not fit to a real outdoor unit of air-conditioner. Especially, the inlet part of the axial fan of real system case is complex and not uniform. So, in order to identify the dominant noise source of axial fan, full outdoor unit analysis is important. Transient CFD analysis of full system was performed by commercial CFD code - SC/Tetra. Dominant noise source of the system was calculated by commercial CFN code - FlowNoise. The results show that not only BPF peaks but also broadband noise are similar to the measured data.

  • PDF

HEV 계전기의 소음분산 저감에 관한 실험적 연구 (Experimental Study on the Reduction of Noise Dispersion for HEV Relay)

  • 김원진
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.324-330
    • /
    • 2013
  • The dispersion of acoustic noise during the turn-on and turn-off switching of HEV(hybrid electric vehicle) relay was experimentally analyzed to identify the reason for the dispersion of noise level. An effective method was proposed to reduce the dispersion of noise level. First, a method to wrap the side of moving core with a tape was adopted to reduce the transverse vibration. It enabled the moving core to make a consistent motion and reduce the dispersion of noise level from switching operation of relay. Second, the dispersion of noise level from vibration transmission of parts such as the outer frame and yoke caulking part of relay were tested to find out main sources. From this result, it was identified that the yoke caulking part made inconsistent transient vibration and noise dispersion.

순시 인텐시티 측정 기법의 개발 및 응용 (Development and Application of Measuring Method for Instantaneous Intensity)

  • 이장우;안병하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.960-963
    • /
    • 2003
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these state, select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

Rack/Pinon 방식의 5-Head 라우터 머신 이송 시스템의 진동해석 (Vibration Analysis of a Rack and Pinon Typed Feed Drive System for a 5-Head Router Machine)

  • 최영휴;최응영;장성현;하종식;조용주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.269-272
    • /
    • 2005
  • In order to prevent a router machine feed drive system from transient operational vibration, this paper presents vibration analysis of a rack and pinion typed feed drive system for a router machine. The feed drive system was mathematically idealized as a 5-degree-of-freedom lumped parameter model. Stiffness parameters of motor-shaft, rack and pinion gears, and machine structure were appropriately considered in the modeling. Computational experiment was carried out to obtain vibrations of the feed drive system during its transient speed operation.

  • PDF