• 제목/요약/키워드: Transient loss

검색결과 384건 처리시간 0.027초

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

전자기 과도현상 해석을 위한 주파수 의존 시스템 등가 (Frequency Dependent Network Equivalent for Electromagnetic Transient Studies)

  • 왕용필;조금식
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1549-1555
    • /
    • 2007
  • The complexity of modern power systems often makes it impractical to model it in its entirety for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). The advantage of using z-domain fitting is that it can be directly implemented in a digital simulation program without any loss of accuracy. Fitting in the s-domain always requires "discretizing" a continuous system and the inherent approximations. This paper presents z-domain rational function formulation and demonstrates the use of it for the assessment of the transient response of the Lower South Island of New Zealand. Moreover by using a well publicized test system and providing complete information on the developed FDNE coefficients other researchers easily benchmark their work against this.

유한요소-전달강성계수법을 이용한 골조 구조물의 과도응답해석 (Transient Response Analysis of Frame Structures Using the Finite Element-transfer Stiffness Coefficient Method (FE-TSCM))

  • 최명수;문덕홍;김성진
    • 한국소음진동공학회논문집
    • /
    • 제12권9호
    • /
    • pp.674-684
    • /
    • 2002
  • In order to decrease remarkably the computation time and storage used in the direct integration method without the loss of accuracy, authors suggest a new transient analysis algorithm. This algorithm is derived from the combination of three techniques, that is, the transfer technique of the transfer stiffness coefficient method, the modeling technique of the finite element method, and the numerical integration technique of the Newmark method. In this paper, the transient analysis algorithm of a frame structure is formulated by the proposed method. The accuracy and computation efficiency of the proposed method are demonstrated through the comparing with the computation results by the direct integration method for three computation models under various excitations.

PT-IGBT의 온도에 따른 과도특성해석 (Transient Analysis of PT-IGBT with Different Temperature)

  • 이호길;류세환;이용국;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.25-28
    • /
    • 2000
  • In this study, Transient Characteristics of the Punch-Through Insulated Gate Bipolar Transistor (PT-IGBT) has been studied. On the contraty to Non-Punch Through Insulated Gate Bipolar Transistor(NPT-IGBT), PT-IGBT has buffer layer It has a simple drive circuit controlled by the gate voltage of the MOSFET and the low on-state resistance of the bipolar junction transistor. In this paper, the transient characteristics with temperature of the PT-IGBT has been analyzed analytically. PT-IGBT is made to reduce switching power loss. Excess Minority carrier distribution inactive base region and base charge, the rate of voltage with time is expressed analytically to include buffer layer.

  • PDF

Transient global amnesia associated with multiple lesions in the corpus callosum and hippocampus

  • Kim, Jin-Ah;Min, Young Gi;Koo, Dae Lim
    • Annals of Clinical Neurophysiology
    • /
    • 제21권2호
    • /
    • pp.102-104
    • /
    • 2019
  • Transient global amnesia is a syndrome of temporary loss of short-term memory and is not accompanied by any other neurological deficit. Diffusion-weighted imaging is useful to improve the diagnostic accuracy of transient global amnesia. We report a 68-year-old woman with multiple lesions on diffusion-weighted imaging in the right corpus callosum and left hippocampus. To the best of our knowledge, this is the first case of a diffusion-weighted imaging lesion in the body portion of the corpus callosum.

순간전압강하 극복을 위한 대용량 유도전동기 제어방식 설계 및 해석 (Design and Analysis of Large Induction Motor Control Coping with Voltage Sag)

  • 조성돈;임성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1056-1058
    • /
    • 1998
  • Voltage dips caused by transmission system faults are usually of a short duration. High speed relaying and breaker operation will typically limit the disturbance to 0.1 seconds. Most motor controllers obtain their control power directly from the bus by means of a control transformer. Under this condition, a voltage dip can cause the contactor to drop out. disconnecting the motor from the line. The rapid re-energizing of the controller is in effect a fast reclosure which may result in motor damage. The time delay re-energizing of controller will result in a greater loss of speed and possibly loss of stability. Other means of controller can be used to prevent the motor from being disconnected from line during the fault. This can be accomplished by DC power controller or mechanically latched controller. This paper demonstrates that DC power controller or mechanically latched type controller to prevent the motor from being disconnected from line during the fault is, the most effective in minimizing speed reduction, transient motor current, transient motor torque and transient shaft torque by EMTP calculation.

  • PDF

Flow Characteristics Analysis for the Chemical Decontamination of the Kori-1 Nuclear Power Plant

  • Cho, Seo-Yeon;Kim, ByongSup;Bang, Youngsuk;Kim, KeonYeop
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.51-58
    • /
    • 2021
  • Chemical decontamination of primary systems in a nuclear power plant (NPP) prior to commencing the main decommissioning activities is required to reduce radiation exposure during its process. The entire process is repeated until the desired decontamination factor is obtained. To achieve improved decontamination factors over a shorter time with fewer cycles, the appropriate flow characteristics are required. In addition, to prepare an operating procedure that is adaptable to various conditions and situations, the transient analysis results would be required for operator action and system impact assessment. In this study, the flow characteristics in the steady-state and transient conditions for the chemical decontamination operations of the Kori-1 NPP were analyzed and compared via the MARS-KS code simulation. Loss of residual heat removal (RHR) and steam generator tube rupture (SGTR) simulations were conducted for the postulated abnormal events. Loss of RHR results showed the reactor coolant system (RCS) temperature increase, which can damage the reactor coolant pump (RCP)s by its cavitation. The SGTR results indicated a void formation in the RCS interior by the decrease in pressurizer (PZR) pressure, which can cause surface exposure and tripping of the RCPs unless proper actions are taken before the required pressure limit is achieved.

유도전동기 드라이브 시스템의 효율성능을 예측하기 위한 손실 모델링 (Loss Modeling in order to Predict the Efficiency Performance of Induction Motor Drive System)

  • 정동화;박기태;이정철
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.56-61
    • /
    • 2000
  • The precise and reliable loss model for induction motor and converter system is very important in order to predict the efficiency performance of variable speed drives. This paper proposes an accurate loss model of induction motor and converter system. The motor losses, such as stator and rotor copper loss, core loss and stray loss, are considered for fundamental and harmonic frequencies. Also considered are the skin effect on rotor resistance, temperature effect on bath stator and rotor resistance, magnetizing inductance saturation, and friction and windage loss. All the above features are incorporated in a synchronous frame dynamic d-q equivalent circuit. The converter system, consisting of a diode rectifier and PWM transistor inverter, is modeled accurately for conduction and switching losses. Validity of the models, in both steady state and transient conditions, is verified by simulations.

  • PDF

메탄/공기 확산화염에서 복사 열손실로 인한 맥동 불안정에 관한 수치해석 (A Numerical Study on Radiation-Induced Oscillatory Instability in CH$_4$/Air Diffusion Flames)

  • 손채훈;정석호
    • 대한기계학회논문집B
    • /
    • 제25권1호
    • /
    • pp.29-35
    • /
    • 2001
  • Radiation-induced oscillatory instability in CH$_4$/Air diffusion flames is numerically investigated by adopting detailed chemistry. Counterflow diffusion flame is employed as a model flamelet and optically thin gas-phase radiation is assumed. Attention is focused on the extinction regime induced by radiative heat loss, which occurs at low strain rate. Once a steady flame structure is obtained for a prescribed value of initial strain rate, transient solution of the flame is calculated after a finite amount of strain-rate perturbation is imposed on the steady flame. Depending on the initial strain rate and the amount of perturbed strain rate, transient evolution of the flame exhibits various types of flame-evolution behaviors. Basically, the dynamic behaviors can be classified into two types, namely oscillatory decaying solution and diverging solution leading to extinction.

복합열화에 의한 형권 고정자권선의 절연신뢰성에 관한 연구 (A Study on the Insulation Reliablity of Form-Wound Stator Windings by Complex Degradation)

  • 이헌돈;김상걸;오현석;왕종배;김기준;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.152-155
    • /
    • 2000
  • PWM inverter-fed traction motor is able to occur problems by additive transient surge stress and harmonic loss in contrast with motor driven by 60Hz sine wave alternating source. Therefore in this paper, test method and standard of existed already were investigate, "thermal + electric" complex degradation test that considered additive degradation occurred by inverter drive carried out in order to obtain insulation reliability of traction motor driven by inverter. It seems that this test method confers large value of application at reliability estimation which the subject of complete motor not windings sample from now on.

  • PDF