A Study on the Insulation Reliablity of Form-Wound Stator Windings by Complex Degradation

복합열화에 의한 형권 고정자권선의 절연신뢰성에 관한 연구

  • 이헌돈 (광운대학교 전기공학과) ;
  • 김상걸 (광운대학교 전기공학과) ;
  • 오현석 (광운대학교 전기공학과) ;
  • 왕종배 (한국철도기술연구원) ;
  • 김기준 (인천전문대학교 제어계측과) ;
  • 이준웅 (한국전기전자재료학회장)
  • Published : 2000.07.01

Abstract

PWM inverter-fed traction motor is able to occur problems by additive transient surge stress and harmonic loss in contrast with motor driven by 60Hz sine wave alternating source. Therefore in this paper, test method and standard of existed already were investigate, "thermal + electric" complex degradation test that considered additive degradation occurred by inverter drive carried out in order to obtain insulation reliability of traction motor driven by inverter. It seems that this test method confers large value of application at reliability estimation which the subject of complete motor not windings sample from now on.

Keywords