• Title/Summary/Keyword: Transient fault

검색결과 418건 처리시간 0.023초

R-type HTS-FCL Model considering transient characteristics

  • Yoon Jae Young;Lee Seung Ryul;Kim Jong Yul
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권2호
    • /
    • pp.35-38
    • /
    • 2005
  • One of the most serious problems in KEPCO system operation is higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(Back to Back) and FCL(fault current limiter). But, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the resistance type HTS-FCL(High Temperature Superconductor Fault Current Limiter) can be one of the most attractive alternatives to solve the fault current problem. To evaluate the accurate transient performance of resistance type HTS-FCL, it is needed that the dynamic simulation model considering transient characteristics during quenching and recovery state. Under this background, this paper presents the EMTDC model for resistance type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching and recovery phenomena by fault current injection and clearing occurs.

연속 웨이블렛 변환의 확대된 위상 지도를 이용한 기어의 초기 퍼팅 결함 진단 (Fault Detection of a Gear with Initial Pitting using the Boomed Phase Map of Continuous Wavelet Transform)

  • 이상권;심장선
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1759-1766
    • /
    • 2001
  • Vibration transient generated by developing localized fault in gear can be used as indicators in gear fault detection. In this paper, we propose the zoomed phase map for a fault signal using continuous wavelet transfers to detect this vibration transient. Local fault induces the abrupt fluctuation of load exciting tooth and phase lag in the vibration signal measured on the gearbox. The relatively large fault like "tip breakage" easily can be detected by the clear fluctuation of exciting load. However, minor fault like "initial pitting"cannot be detected using the load fluctuation. To defect this kind of minor fault, the phase map for a fault signal is taken into account. The phase lag by minor fault is observed well in the zoomed phase map.

웨이브릿 기법을 이용한 리커시브 실시간 고장점 표정 시스템 연구 (Recursive Real Time Fault Locator with Wavelet Method)

  • 이성우;하복남
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1522-1530
    • /
    • 2008
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.

혼합송전선로에서 고저항 지락사고시 케이블 과도현상 해석 및 전력케이블 시스 접지저항에 따른 CCPU 과도특성 모의 (Modeling and Transient Analysis of Cable in Combined Transmission Line with HIF and Analysis of Transient Characterstic in CCPU of Uderground Cable)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 2000
  • This paper discribes the modeling and transient analysis of cable in combined transmission line under high impedance fault(HIF). And also, transient characterstic analyzed on cable covering protection unit(CCPU) is presented. Modeling of the combined transmission line is established in PSCAD/EMTDC V3. The required data to analyze the transient phenomena is given from the actual system. The results show the HIF modeling in cable, fault current according to the value of fault resistance. And also when the value and method of grounding resistance is changed in CCPU, simulation results are presented.

  • PDF

지중송배전계통에서 과도상태시 공통접지의 영향 분석 (Analysis of Common Grounding Effect during the Transient State in Underground Transmission and Distribution Systems)

  • 임광식;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.191-197
    • /
    • 2008
  • This paper describes the effect of transient state in underground transmission and distribution lines installed together in the same tunnel. Two systems installed in the same tunnel are operated by the common grounding. This paper analyzed that how much one of the two kinds of systems influences the other systems during the transient state by EMTP/ATPDraw. Single line-to-ground fault and lightning surge were selected in transient state condition. These cases were simulated variously according to the variation of common grounding magnitude, fault location and lightning surge magnitude. It is evaluated that the analyzed results will be used for establishment and operating materials of common grounding in the same tunnel.

765kV 비연가 송전계통 과도 특성에 관한 고찰 (A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권7호
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

우주용 중복구조 링 카운터를 위한 고장 진단 및 자가 복구 시스템 (A Fault Detection and Self-Recovery System for Space-Borne Dual Ring Counters)

  • 곽성우;양정민
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.120-126
    • /
    • 2013
  • This paper proposes a novel scheme of fault detection and self-recovery for space-borne dual ring counters subject to transient faults. The considered ring counter is equipped with hardware redundancy, but it has a limited output domain where direct access to the current state is unavailable. We employ the theory of corrective control to detect any transient fault occurring to the counter bits and to realize immediate self-recovery of the ring counter back to the normal state. The structure of the fault-tolerant controller is designed to be minimal regardless of the counter size. To validate the applicability, we implement the proposed system on a commercial FGPA board.

OF 케이블 계통에서 과도상태시 에너지 특성 검토 (A Study on Energy Characteristics in Transient States of OF Cable Systems)

  • 정채균;이종범;강지원;이동일;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

고장점 탐색 장치를 위한 H/W 설계 (H/W Design for Fault Location System on Underground Power Cable System)

  • 이재덕;류희석;정동학;최상봉;남기영;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.709-711
    • /
    • 2005
  • Developing fault location system for underground power cable which can detect its fault location exactly require very high speed data acquisition and signal processing capability. We are developing fault location system which is different from conventional fault locator. This fault location system monitor underground power cable by using on-line speed current sensor and if there are an accident, it record its transient signal and calculate fault location by analyzing it. Signals which acquired when power cable fault arise, showed transient characteristics and its frequency band is very hish. So, to develop fault location system, we designed special high speed data acquisition and signal processing board. In this thesis, we describe on data acquisition and signal processing H/W design for fault location system on underground power cable.

  • PDF

Cascaded Propagation and Reduction Techniques for Fault Binary Decision Diagram in Single-event Transient Analysis

  • Park, Jong Kang;Kim, Myoungha;Kim, Jong Tae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권1호
    • /
    • pp.65-78
    • /
    • 2017
  • Single Event Transient has a critical impact on highly integrated logic circuits which are currently common in various commercial and consumer electronic devices. Reliability against the soft and intermittent faults will become a key metric to evaluate such complex system on chip designs. Our previous work analyzing soft errors was focused on parallelizing and optimizing error propagation procedures for individual transient faults on logic and sequential cells. In this paper, we present a new propagation technique where a fault binary decision diagram (BDD) continues to merge every new fault generated from the subsequent logic gate traversal. BDD-based transient fault analysis has been known to provide the most accurate results that consider both electrical and logical properties for the given design. However, it suffers from a limitation in storing and handling BDDs that can be increased in size and operations by the exponential order. On the other hand, the proposed method requires only a visit to each logic gate traversal and unnecessary BDDs can be removed or reduced. This results in an approximately 20-200 fold speed increase while the existing parallelized procedure is only 3-4 times faster than the baseline algorithm.