• Title/Summary/Keyword: Transformer Type Superconducting Fault Current Limiter(SFCL)

Search Result 48, Processing Time 0.023 seconds

Analysis of the Initial Fault Current Limiting Point of the SFCLs (고온초전도 전류제한기의 초기사고전류 제한시점 분석)

  • Park, Chung-Ryul;Du, Ho-Ik;Doo, Seung-Gyu;Kim, Yong-Jin;Kim, Min-Ju;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.292-292
    • /
    • 2008
  • The superconducting fault current limiter(SFCL) can be used to limit fault current level in electrical transmission line and power system. Up to now, there are several kinds of SFCL that have proposed and it is expects that they will be applied to appropriated position considering their own properties; initial fault current limiting instant and the current limiting characteristics. In this paper, we investigated the initial fault current limiting instant and the amplitude of initial fault current in the resistive type, the flux-lock type, the flux-coupling type and the transformer type SFCL. Experiment results show that the initial fault current limiting instant and the amplitude of initial fault current of the SFCLs are dependant on the ratio of inductance of primary and secondary coils.

  • PDF

Fault Current Limiting Characteristics of Resistive Type SFCL using Transformer (변압기를 이용한 저항형 고온초전도 전류제한기의 한류 특성)

  • 임성훈;최효상;고석철;이종화;강형곤;한병성
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.288-290
    • /
    • 2003
  • The transformer is expected to be an essential component of resistive type superconducting fault current limiter (SFCL) for both the increase of voltage ratings in SFCL and the simultaneous quench due to different critical current between HTSC elements. However, for the design to prevent the saturation of iron core and the effective fault current limitation, the analysis for operation of SFCL with consideration for the magnetization characteristics are required. In this paper, the fault current limiting characteristics related with the magnetization ones were investigated through the variation of the ratio of the number of turns in the 1st and the 2nd windings. The proper design condition with variation of the number of turns to make the effective fault current limiting operation could be determined.

  • PDF

Characteristics according to the spot at the beginning of the fault current (개선된 자속구속형 전류제한기의 사고 시점에 따른 사고전류제한 특성)

  • Kim, Yong-Jin;Du, Ho-Ik;Lee, Dong-Hyeok;Han, Sang-Chul;Lee, Jeong-Phil;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.189-189
    • /
    • 2010
  • The Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In a normal condition, the flux generated from a primary coil is cancelled out by its structure and the zero resistance of the YBCO thin films. When a fault occurs, the resistance of the YBCO coated conductor was generated and the fault current was limited by the SFCL. In this paper, we investigated the fault current limiting characteristics through the spot at the beginning of the fault current in the Improved flux-lock type SFCL. The experiment results that the fault current limiting characteristics was difference according to the point of a fault current started. Through the analysis, it was shown that shorter the time of a phase transition.

  • PDF

Characteristics of Hybrid-Type SFCL according to the Parallel Connection of Secondary Windings (2차권선의 병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Hwang, Jong-Sun;Cho, Yong-Sun;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.208-211
    • /
    • 2006
  • We have analyzed operating characteristics of hybrid-type superconducting fault current limiter (SFCL) according to the parallel connection of secondary windings with $YBa_{2}Cu_{3}O_{7}$ (YBCO) films. The turn ratio between the primary and secondary windings of each reactor was 63:21. Hybrid-type SFCL using a transformer with parallel reactors could reduce the unbalanced quench caused by differences of the critical current density between YBCO films. We found that hybrid-type SFCL having parallel connection induced simultaneous quench between the superconducting elements. The quench-starting point at this time was almost same. When the applied voltage was 200V, the limiting current in the hybrid-type SFCL with a serial connection was lowered to 34 percent than that in the SFCL with a parallel connection. In the meantime, when the voltage generated in the superconducting elements was the same, the current value in the parallel connection was 60 percent less than in the serial connection. The voltage generated in the primary winding also showed the similar behavior. In conclusion, we found that the fault current was limited more effectively in the SFCL with the serial connection but the power burden of the superconducting elements was reduced in the parallel connection.

  • PDF

Transient Characteristics of a Transformer Type SFCL Applying the Superconductor and the Normal-conductor into the Secondary Winding (초전도체 및 상전도체의 변압기 2차측 적용에 따른 변압기형 SFCL 특성 비교)

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.873-877
    • /
    • 2016
  • This paper proposed the structure that applied superconductors to the neutral line of a transformer and applied the normal conductors to the third line. The superconductor applied to the neutral line of a transformer limited the peak value of initial fault current, while the normal conductor finally limited the fault current. In order to secure the operating reliability of transformer type Superconducting Fault Current Limiter (SFCL) of previously proposed structure, we analyzed the operating characteristics according to the fault types. We tested a line-to-ground fault and a line-to-line fault. As a result of the experiment, all the faults showed that the superconductor stably limited the peak-value of initial fault current. Also, the normal conductor finally limited the fault current. Based on this research results, We thought that if the structure of inserting superconductor into the neutral line is applied to the real system, it could improve the reliability and stability of the power system.

개선된 자속구속형 전류제한기의 동작 특성 분석

  • Kim, Yong-Jin;Du, Ho-Ik;Kim, Min-Ju;Lee, Dong-Hyeok;Han, Byeong-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.215-215
    • /
    • 2009
  • Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through initial line current after fault initiation. through the analysis, it was shown that the smaller initial line current is superior to current limiting characteristics and a point of view of power burden of the YBCO coated conductor.

  • PDF

Current Limiting Characteristics of Separated Three-phase Flux-coupling Type SFCL according to Winding Number of Coil 2 and Winding Direction (삼상 분리형 자속커플링 전류제한기의 2차 권선의 턴 수 및 결선 방향에 따른 전류제한 특성)

  • Kim, Yong-Jin;Du, Ho-Ik;Doo, Seung-Gyu;Kim, Min-Ju;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.694-697
    • /
    • 2009
  • The separated three-phase flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through winding number of coil 2 and winding direction in the flux-coupling type SFCL. Through the analysis, it was shown that additive polarity condition and lower winding number of coil 2 have advantaged from the point of view of fault current limiting and burned of YBCO coated conductor.

Analysis on Fault Current limiting and Recovery Characteristics of Flux-Lock Type Superconducting Fault Current Limiter According to Increase of Applied Voltage (전압증가에 따른 자속구속형 초전도 한류기의 전류제한 및 회복특성 분석)

  • Oh, Kum-Gon;Han, Tae-Hee;Cho, Yong-Sun;Cho, Hyo-Sang;Choi, Myoung-Ho;Han, Young-Hee;Sung, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.107-112
    • /
    • 2007
  • The flux-lock type SFCL consists of transformer with primary and secondary windings connected to a superconducting element in serial. It can be divided into the subtractive and the additive polarity windings according to the winding direction. It could change the fault current limiting characteristics according to the inductance ratio between the coil 1 and coil 2. We investigated the voltage-current characteristics of the flux-lock type SFCL according to the increment of applied voltage. When the applied voltage of the SFCL with the subtractive and the additive polarity windings was increased a initial limiting current ($I_{ini}$) and the quench time of the superconducting element were increased. The recovery time of the superconducting element was increased by increment of applied voltage. Therefore, it was confirmed that recovery characteristics in the flux-lock type SFCL were largely dependent on the consumed energy of a superconducting element because of increment of the consumption power into the superconducting element.

Operating Characteristics of Capacity Increase in a Flux-Lock Type Superconducting Fault Current Limiter (자속구속형 초전도 전류제한기의 용량증대를 위한 동작특성)

  • Nam, Gueng-Hyun;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Lee, Na-Young;Han, Tae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.200-202
    • /
    • 2006
  • We investigated the operating characteristics of a flux-lock type superconducting fault current limiters according to the number of the serial connection each the superconducting element at the additive polarity winding of a transformer. This SFCL consists of two coils wound in parallel on the same iron core, and the secondary coil is connected to the elements in series. Operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. It turns ratio between the primary and the secondary coils is 63:21. The analysis of voltage, current, and resistance in serial connection each element was performed to increase the applied voltage of flux-lock type SFCL. When the applied voltage was 200/$\sqrt{3}[V_{rms}]$ with three elements connected in seres, the peak value of the line current increased up to 26,24[A]. On the other hands, resistive SFCL increased up to 36.35[A], under the same conditions. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

  • PDF

Characteristics of a Hybrid-type SFCL with Serial and Parallel Connection of Secondary Circuit (2차회로의 직.병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Nam, Goung-Hyun;Lee, Na-Young;Han, Tae-Hee;Choi, Choi-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.393-395
    • /
    • 2006
  • We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the serial and parallel connections of secondary circuits. The hybrid-type SFCL consists of a transformer, which has a primary winding and several secondary windings with $YBa_2Cu_3O_7$ films connected in series and parallel. In order to increase the capacity of the SFCL, the serial connection between each current limiting unit is necessary. The hybrid-type SFCL with the serial connection in secondary circuits could show superior characteristics than those of the parallel connections in the current limiting and quench time. The resistances generated in the superconducting units were also lowered at the parallel connections. We confirmed that the parallel connection reduced the power burden of each superconducting unit under the same conditions because of the simultaneous quenching between superconducting units.

  • PDF