• 제목/요약/키워드: Transfer unit

검색결과 853건 처리시간 0.032초

복소캠을 이용한 캠 타입 이송장치의 설계 (Study on the Design of Cam-type Transfer Unit using Conjugate Cam)

  • 이택민;이동윤;양민양
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.844-847
    • /
    • 2003
  • This thesis suggests design considerations and solutions for cam type transfer unit in which feed, lift, and clamp motions are occurred by cams. For fast transferring and avoiding cam breakage, each designed cam must satisfy the given specifications such like velocity, acceleration, jerk, pressure angle, ram thickness, and torque. To reduce absolute torque magnitude, conjugate cam is suggested. Conjugate cam eliminates the redundant pre-load by using complementary cam and follower to avoid jumping between them. The result from the prototype shows the reductions of the absolute torque value, and it indicates that conjugate cam could enhance the working speed of cam type transfer unit and extend of the life span of cam type transfer unit.

  • PDF

대형 캠 타입 이송장치의 설계에 관한 연구 (Study on the Design of Cam-type Transfer Unit)

  • 이택민;이동윤;양민양
    • 대한기계학회논문집A
    • /
    • 제28권1호
    • /
    • pp.31-39
    • /
    • 2004
  • This paper presents design solutions for cam type transfer unit in which feeding, lifting, and clamping motions are generated by cams. In order to achieve faster transfer motion, each designed cam must satisfy the given specifications such as velocity, acceleration, jerk, pressure angle, cam thickness, and torque. To reduce absolute torque magnitude and torque variation, a conjugate cam and a torque reduction cam are used respectively. The conjugate cam eliminates the redundant pre-load by using complementary cam to avoid jumping between a cam and a follower. The torque reduction cam reduces the torque variation by applying opposite torque to a cam shaft. The experimental result shows the reductions of the absolute torque value and torque variation. The improvement of working speed and life span of cam type transfer unit can be expected.

성능선도에 의한 다통로 판형열교환기의 간이설계법 (An easy-to-use design procedure for multipass plate heat exchangers based on the performance plots)

  • 유호선;이근휘;방보청
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.250-261
    • /
    • 1999
  • Based on a set of performance plots relating the design variables to the imposed conditions, an easy-to-use and versatile design procedure for chevron-type multipass plate heat exchangers is developed. In order for the present procedure to cover multipass with unequal passes and non-unity ratio of heat capacity rate, each stream number of transfer unit is adopted as the basic design variable instead of the exchanger number of transfer unit. It is found that there exists a unique relation between the stream and exchanger number of transfer units regardless of the chevron angle and the plate length. In addition, for a given value of the pressure drop the heat transfer area per unit mass flow rate can be expressed in terms of the stream number of transfer unit only. These two relationships in the form of simple plots constitute the framework of design. The sample results in comparison with the available data indicate that the present procedure includes the previous ones as a subset, and that every design method is affected essentially by the selection of specific correlations for the heat transfer coefficient and the friction factor.

  • PDF

관 단면형상 변화에 따른 열전달 특성에 관한 수치해석적 연구 (Numerical Study for Heat Transfer Characteristics Varying Cross-Sectional Shape of a Tube)

  • 박훈채;최항석;김석준
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.560-566
    • /
    • 2012
  • Numerical study has been carried out to investigate heat transfer and pressure drop characteristics for streamlined shape tubes. The flow and thermal fields are investigated with varying diameter ratio of the tube ranging from 0.4 to 2.5 and Reynolds number ranging from 10,000 to 30,000. The results show that heat transfer per unit fan power is maximum at $D_2/D_1=0.8$. Furthermore, the heat transfer per unit fan power of streamlined shape tubes was compared with circular tube. The heat transfer per unit fan power of streamlined shape tube was larger than that of circular tube.

Floated Wafer Motion Modeling of Clean Tube system

  • Shin, Dong-Hun;Yun, Chung-Yong;Jeong, Kyoo-Sik;Choi, Chul-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1264-1268
    • /
    • 2004
  • This paper presents a wafer motion modeling of the transfer unit and the control unit in the clean tube system, which was developed as a means for transferring the air-floated wafers inside the closed tube filled with the super clean airs. The motion in the transfer unit is modeled as a mass-spring-damper system where the recovering force by air jets issued from the perforated plate is modeled as a linear spring. The motion in the control unit is also modeled as another mass-spring-damper system, but in two dimensional systems. Experiments with a clean tube system built for 12-inch wafers show the validity of the presented force and motion models.

  • PDF

Ralu-Pack 250YC를 충전한 충전탑에서 암모니아가스 제거에 관한 연구 (A study on Removal of $NH_3$ Gas in a Towar using a Ralu-Pack 250YC as a Packing Material)

  • 김석택
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.389-392
    • /
    • 2000
  • In this study a packed tower was selected for the treatment apparatus of $NH_3$ gas produced in industry. Formerly latticework packing has been used in preventive facility of treatment of $NH_3$ gas. However recently metallic Ralu-Pack 250YC. structured packing is usually being used in petrochemical production plant. This study is for the application the packing to the $NH_3$ gas treatment in wet scrubbing process. In Air/water system hydraulic pressure drop dependent of specific liquid load and gas capacity factor was continuous and parallel from graph. The tower height can be determuined by the number of transfer unit and the height of transfer unit influenced on liquid distribution.

  • PDF

소아중환자실 퇴실 시 환아 어머니의 불확실성과 전동불안 (Uncertainty and Transfer Anxiety of Pediatric Patients' Mothers upon Discharge from the Pediatric Intensive Care Unit)

  • 송민경;방경숙
    • 부모자녀건강학회지
    • /
    • 제15권2호
    • /
    • pp.80-88
    • /
    • 2012
  • Purpose: This study was done to investigate the level of uncertainty, transfer anxiety, and to identify the participant's characteristics those influence them by targeting the mothers of transferred patients from the pediatric Intensive Care Unit (PICU) to the general ward. Methods: This study was a descriptive correlational study. The participants were 94 mothers of children who had been scheduled to transfer from the PICU. Results: The item mean score for uncertainty was 2.16 (4 scale), transfer anxiety was 2.15 (4 scale). There were statistically significant positive correlation between uncertainty and transfer anxiety (r=.591). The level of uncertainty significantly differed according to education level (p=.035), duration of marriage (p=.043), and monthly income (p=.022). The level of transfer anxiety significantly differed according to religion (p=.044), duration of marriage (p=.043), and severity of illness at transfer (p=.047). Conclusion: In order to reduce the transfer anxiety and uncertainty of the mothers of patients, efficient communication with medical staff and clear informations are needed to reduce ambiguity. Also, standard protocol should be developed for improving communication among medical staffs.

  • PDF

수송용 DPH HVAC 히팅유니트장치의 열유동 시뮤레이션평가연구 (A Study on the Heat Transfer Characteristics of Heating Unit in DPH HVAC)

  • 노홍구;임경빈;노종호;이영기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.605-610
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of heating unit for room using 3-D numerical-analysis in order to design heating unit. The temperature comparison processes were done with various numerical conditions. In addition, the optimal conditions of heating unit design were proposed as inlet temperature, the inlet flow, heater power, and vessel size.

  • PDF

우퍼 스피커 유닛의 열전달 특성에 대한 실험적 연구 (Experimental study on the heat transfer characteristics of woofer speaker unit)

  • 김형진;김대완;이무연
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.2623-2627
    • /
    • 2014
  • 본 연구의 목적은 우퍼 스피커 유닛의 열전달 특성 고찰하기 위하여 입력신호를 500Hz, 1000Hz, 2000Hz 그리고 3000Hz로 변화시키면서 실험을 수행하였다. 이를 위하여, 우퍼 스피커 유닛의 더스트 캡을 제거하고 보빈 내부에 열전대를 부착하여 보이스 코일에서 발생되는 온도를 측정하였고 주변으로의 열전달 특성을 파악하였다. 결과적으로, 입력신호가 감소할수록 보이스 코일 온도가 증가하였고, 입력신호가 증가할수록 스피커 유닛 각 부품의 온도편차가 증가하는 것을 확인하였다. 또한 1800sec및 입력신호 500Hz에서 보이스 코일 온도는 3000Hz에 비하여 48.4% 감소하였다.

암모니아 유니트 쿨러의 열성능 해석 (Analysis on the Thermal Performance of an Ammonia Unit Cooler)

  • 최재광;김무근;박병규
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.