• 제목/요약/키워드: Transfer rate

검색결과 4,698건 처리시간 0.026초

고체입자 순환유동층 열교환기의 열전달률 및 압력강하 측정 (Measurement of Heat Transfer Rates and Pressure Drops in a Solid Particle Circulating Fluidized Heat Exchanger)

  • 이금배;전용두;박상일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.817-824
    • /
    • 2000
  • The fluidized solid particles not only increase heat transfer rates but have a cleaning function eliminating contaiminated substances caused from condensate water. An experiment was performed to measure heat transfer rates and pressure drops in a fluidized heat exchanger with circulating solid particle for constant heat transfer rate. As a results, the heat transfer rate increased by 26.9~2.6%, heat transfer coefficient by 11.9~2.7%, and pressure drop by 79.1~10.9% at the gas velocity of 6.1 ~12.1 m/s and solid particle flow rate of 100~50 kg/h with the heat exchanger of H: 50 mm, $D_p=2 in,\; and\;D_{BP}$=30 mm.

  • PDF

Decentralized Supply Chain Coordination with Revenue Sharing Mechanism: Transfer Pricing Heuristics and Revenue Share Rates

  • Chen, Hung-Yi;Wu, Hsiao-Chung
    • Industrial Engineering and Management Systems
    • /
    • 제8권4호
    • /
    • pp.213-220
    • /
    • 2009
  • A revenue sharing contract is one of the mechanisms that coordinate decision makers in a decentralized supply chain toward the consensual goal. The transfer prices between different echelons in the supply chain influence the total supply chain profits. The study aims to explore various transfer pricing heuristics on the supply chain coordination in terms of the supply chain profits and their interactions with the revenue sharing rate. A model is proposed for formulating the collaborative production and distribution planning in a decentralized supply chain with the revenue sharing mechanism. Experiment results indicate that the transfer price and the revenue sharing rate affect significantly the coordination. Among the studied pricing heuristics, the variable-cost pricing method led to the best SC profits. Raising the revenue sharing rate reduced the SC profits no matter what heuristics were employed. Furthermore, the experiments provide us clues for finding the optimal transfer price for the supply chain.

Mesh 스크린을 이용한 충돌제트 열전달 제어에 관한 연구 (Control of Impinging Jet Heat Transfer with Mesh Screens)

  • 조정원;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.267-271
    • /
    • 2000
  • The local heat transfer rate of an axisymmetric submerged air jet impinging on normal to a heated flat plate was investigated experimentally with varying solidity of mesh screen. The mean velocity and turbulent Intensity profiles of streamwise velocity component were measured using a hot-wire anemometry. The temperature distribution on the heated flat surface was measured with thermocouples. The screen installed in front of the nozzle exit(behind of 35mm) modify the jet flow structure and local heat transfer characteristics. For higher solidity screen, turbulence intensity at core lesion is high and increases the local heat transfer rate at nozzle-to-plate spacings(L/D<6). For larger nozzle-to-plate spacings(L/D>6), however, the turbulent Intensities of all screens tested in this study approach to an asymptotic curve, but the small mean velocity at the core region reduces the local heat transfer rate for high solidity screens.

  • PDF

한우 체외수정란의 체외배양, 동결보존 및 이식에 관한 연구 III. 한우 체외수정란의 이식 (Studies on In Vitro Culture, Freezing and Transfer of Korean Native Cattle Embryos Fertilized In Vitro III. Transfer of Korean Native Cattle Embryos Fertilized In Vitro)

  • 김일화;손동수;이호준;이동원;서국현;이광원;장인호
    • 한국수정란이식학회지
    • /
    • 제11권2호
    • /
    • pp.137-144
    • /
    • 1996
  • The present study was carried out to obtain the pregnancy and delivery rate following transfer of fresh and frozen-thawed Korean native cattle(KNC) blastocysts(1~4 em-bryos / head) produced in vitro to Holstein recipients. The pregnancy rate of fresh and frozen-thawed KNC blastocysts produced in vitro was 50%(7 /14 heads) and 38.5%(5 /13 heads), respectively. The pregnancy rate of frozen-thawed KNC blastocysts produced in vitro frozen using 1.5M ethylene glycol and 1.4M glycerol for cryoprotectant was 33.3%(2 /6 heads) and 42.9 %(3 /7 heads), respectively. Seven calves including 2 sets of twin were born fiom 5 pregnant recipients receiving eleven fresh blastocysts. Three pregnant recipients were aborted among four pregnant recipients receiving twelve frozen-thawed blastocysts and one calf was born from the rest of one pregnant recipient.

  • PDF

소득이전의 빈곤완화 및 빈곤이행 효과에 관한 연구 (The Effect of Income Transfer on Poverty Rate)

  • 김교성
    • 한국사회복지학
    • /
    • 제48권
    • /
    • pp.113-149
    • /
    • 2002
  • The primary purpose of this study is to analyze the decreasing effect of public and private income transfers on poverty rate. Two year data of Korean Labor and Income Panel Study (KLIPS, 1998, 1999) are used for the analysis, and 1/2 of median income and 1/3 of mean income are adopted to measure poverty rate. Although private income transfer contributes more to reduce the rate than the public transfer, the main effect for decreasing poverty rate is forced by the wage. Statistically significant variables that affect to the exit of poverty based on the logistic regression analysis are number of family members(-), wage(+), property income(+), social insurance benefit(+), and the transfer income(+). Therefore, the future policy should be more related with the active labor market policy for developing better human resources among the poor family.

  • PDF

가토의 수정란이식에 관한 연구 I. 계절이 배란율과 수태율에 미치는 영향 (Studies on Embryo Transfer in Rabbit I. Effect of Season on Ovulation and Pregnancy Rate)

  • 최화식;임경순;이용빈;정구민;박영식
    • 한국수정란이식학회지
    • /
    • 제2권1호
    • /
    • pp.33-35
    • /
    • 1987
  • This study was carried out to investigate the seasonal effect on the recovery rate of embryos in donors and on the conception rate in recipients following embryo transfer. The results obtained from this experiment were summarized as follows: 1. The ovulation point in winter and summer was 28.6 and 28.6, respectively. There was no difference in ovulation point between two seasons. More embryos recovered in the winter (27,0) than the summer (20.9). 2. The number of CL, unruptured follicle, hemorrhagic follicle, young born and pregnancy rate in the winter were 6.0,4.8,1.5,1.8 and 75%, and those in the summer were 2.9,5.7, 3.8, 2.2 and 46.7%, respectively. The rate of synchronization of recipients in the winter showed better results than that in the summer.

  • PDF

FAPO 제올라이트 흡착제 코팅을 통한 핀-관 열교환기 운전조건별 열전달 성능특성 (Heat Transfer Characteristics of Fin-Tube Heat Exchanger Coated with FAPO Zeolite Adsorbent at Different Operating Conditions)

  • 정철기;김용찬;배경진;차동안;권오경
    • 동력기계공학회지
    • /
    • 제21권3호
    • /
    • pp.93-101
    • /
    • 2017
  • In conventional adsorption chamber, adsorbent is embedded in between heat exchanger fins by wire mesh. This method impedes heat and mass transfer efficiency. So in this study, to improve the heat transfer performance of heat exchanger, a fin-tube exchanger was coated with FAPO (Ferroaluminophosphate) zeolite adsorbent. The fin-tube heat exchanger has a fin pitch of 1.8 mm with a variation of adsorbent coating thickness of about 0.1 mm, 0.15 mm and 0.2 mm. By varying cooling water temperature and chilled water temperature respecively, heat transfer rate and overall heat transfer coefficient were investigated. As a result, the heat transfer rate and overall heat transfer coefficient increase with decreasing cooling water temperature and increasing chilled water temperature. Under the basic conditions, the heat transfer rate of heat exchanger with 0.2 mm coating thickness is 11% and 43% higher than that of 0.1 mm and 0.15 mm, respectively. The overall heat transfer coefficient is $189.1W/m^2{\cdot}^{\circ}C$, it is two times lager than that of 0.1 mm.

수평관군 흡수기의 열 및 물질 전달특성에 관한 실험적 연구 (Experimental Study on Heat and Mass Transfer Characteristics in bundles of horizontal absorption tubes)

  • 설원실;정용욱;문춘근;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.113-120
    • /
    • 2000
  • On the absorber of absorption chiller/heater, LiBr solution at high concentration is sprinkled on a bundle of horizontal tube cooled by cooling water. In this case, the conditions of LiBr solution and cooling water have an influence on heat/mass transfer coefficient in this system. Therefor it is important to find optimal operation conditions of absorption chiller/heater to save energy. Heat and mass transfer coefficient increased with the increase of solution flow rate, and also heat and mass transfer rate increased but overall heat and mass transfer coefficient decreased by increasing the solution concentration within the experimental range. The superheating of the solution resulted in superior heat transfer character to a state of equilibrium from the point of heat flux and overall heat transfer coefficient.

  • PDF

수직관(수직관)내를 흘러내리는 액막식흡수기(液膜式吸收器)의 흡수(吸收) 및 열전달(熱傳達) 특성(特性) (제(第)3보(報), 증발기(蒸發器)의 냉동능력(冷凍能力)과 흡수기(吸收器)의 난방능력(暖房能力)) (Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (3rd. Report, Refrigerating Capacity in Evaporator and Heating Capacity in Absorber))

  • 엄기찬;카시와기 타카오;서정윤
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.175-181
    • /
    • 1994
  • This paper deals with the correlation of absorption rate in absorber and evaporation rate in evaporator. The evaporator consists of a copper tube of 10mm dia, and 600mm long and chilled water flowing through the tube is fed by the chilled water circulator. The flowrate of LiBr-water solution in the absorber plays a significant role in determining the magnitude of the heat transfer rate from chilled water to refrigerant There exists a flowrate of solution which has a maximum value of heat transfer. It is interesting to note that the absorption rate of absorber increases with increasing the heat transfer rate of the evaporator. Also, absorption rate increases with evaportation rate, and the ratio(the former/the other) depends on the inlet temperature of LiBr-water solution in the absorber. The heating capacity in the absorber is higher than the refrigerating capacity in the evaporator.

  • PDF

비디오 스트리밍을 위한 적응적 전송 미들웨어의 구현 (Implementation of Adaptive Transmission Middleware for Video Streaming)

  • 김영주
    • 한국정보통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.637-644
    • /
    • 2004
  • 본 논문은 패킷 기반 네트워크의 유동적인 환경 변화와 전송하는 비디오 데이터의 특성을 함께 고려하여 비디오 데이터를 스트리밍하는 적응적 전송 미들웨어를 구현하고 성능을 평가하였다. 적응적 전송 미들웨어는 SR-RTP 기반의 스트리밍 모듈과 TFRC 기반의 전송률 제어 모듈로 구성되며, SR-RTP 기반의 스트리밍 모듈은 패킷 손실에 의해 손실된 비디오 데이터 중에서 중요도가 높은 데이터만을 선별적으로 재전송하여 패킷 재전송에 따른 전송 지연의 부담을 줄임과 동시에 패킷 손실에 따른 에러를 크게 감소시킨다. TFRC 기반의 전송률 제어 모들은 TCP 기반의 데이터 전송과 정당하게 네트워크의 전송 대역폭을 공유하면서 최적의 전송 대역폭을 산출하여 전송률을 제어함으로써 유동적으로 변하는 전송 대역폭에 적응적으로 비디오 데이터의 전송률을 제어한다. 외부 인터넷 환경에서 적응적 전송 미들웨어를 적용하여 비디오 스트리밍을 실험하고 패킷 손실에 대한 복구 성능과 스트리밍 지터 정도를 측정하여 분석한 결과, 적응적 전송 미들웨어를 적용하지 않은 경우와 비교하여 상대적으로 높은 스트리밍 성능을 보였다.