• 제목/요약/키워드: Transfer of B/L

Search Result 357, Processing Time 0.028 seconds

Numerical Analysis of New Proposals to Enhance Heat Transfer in MCFC'S Preconverter (열전달 향상을 위한 새로운 MCFC 연료전지용 프리컨버터의 수치해석)

  • Sohn, Chang Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.753-758
    • /
    • 2013
  • In this study, two proposals for the wall heating preconverter of an MCFC are numerically studied to resolve hot temperature generation near the wall by the low thermal conductivity of the catalyst. The numerical results show that the inserted porous cupper plates on the catalyst evidently improve heat transfer and realize more uniform reforming in the preconverter. The calculated results for the preconverter with a circumference empty space of catalyst located at center, 1/2 and 4/5 from center line are compared. The circumference empty space located at 1/2 position shows better results than other cases, but the positive effect on the uniform reforming process is less than in the case of inserted cupper porous plates on the catalyst.

Performance Predictions of the Planar-type Solid Oxide Fuel Cell with Computational Flow Analysis (II) - Non-isothermal Model - (유동 해석을 이용한 평판형 고체 산화물 연료전지의 성능 특성 분석 (II) - 비등온 모델 -)

  • Hyun, Hee-Chul;Sohn, Jeong L.;Lee, Joon-Sik;Ro, Sung-Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.963-972
    • /
    • 2003
  • Performance characteristics of the planar-type solid oxide fuel cell (SOFC) are investigated by the analysis of flow fields coupled with heat and mass transfer phenomena in anode and cathode channels. For these purposes, performance analysis of the SOFC is conducted based on electrochemical reaction phenomena in electrodes and electrolyte coupled with flow fields in anode and cathode channels. In the present study, the isothermal model adopted in the previous paper prepared by the same authors is extended to the non-isothermal model by solving energy equation additionally with momentum and mass transfer equations using CFD technique. It is found that the difference between isothermal and non-isothermal models come from non-uniform temperature distribution along anode and cathode electrodes by solving energy equation in non-isothermal model. Non-uniform temperature distribution in non-isothermal model contributes to the increase of average temperature of the fuel cell and influences its performance characteristics.

A Study on Practical Problems of the Sea Waybill (해상화물운송장의 실용상의 문제점에 관한 연구)

  • Han, Nak-Hyun
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.23
    • /
    • pp.249-288
    • /
    • 2004
  • The active use of the container vessel has brought with it high speed and reduced transit time ; however, the system of delivering the goods via B/L at the destination has lagged behind technical advances, becoming a burden to today's international traders, especially consignees and/or importers. More recently the sea waybill(SWB), that is to say an ocean-type AWB, has come on the scene. In Europe and the USA the use of SWB has increased significantly, but has also left room for improvement due to its short history of use. However, Recently, more attention is paid to SWB as a means to solve the B/L Crisis is getting more and more serious. In addition, due to its non-negotiability, the sea waybill could easily be replaced by messages sent between the interested parties by Electronic Data Interchange. With the paper document, transfer of title is fulfilled by transferring the original bill of lading to the buyer of the goods. However, in an electronic environment this is difficult to replicate. A number of solutions have been investigated, including using an electronic bill of lading, by controlling changes in title to goods through irrevocable, but transferable instructions to the carrier, or by appointing an independent electronic data registry, or replacing the bill of lading with a sea waybill, which is non-negotiable. The purpose of this study is to investigate some problems which may hinder SWB from coming into wide use and to analyse how to solve problems due to introduction of electronic sea waybill.

  • PDF

Measurement of Average Pool Boiling Heat Transfer Coefficient on Near-Horizontal Tube (수평 가까운 튜브 표면의 평균 풀비등 열전달계수의 측정)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.81-88
    • /
    • 2014
  • An experimental study is performed to obtain an average heat transfer coefficient around the perimeter of a near horizontal tube. For the test a stainless steel tube of 50.8 mm diameter submerged in water at atmospheric pressure is used. Both subcooled and saturated pool boiling conditions are considered and the inclination angle of the tube is changed from the horizontal position to $9^{\circ}$ in steps of $3^{\circ}$. In saturated water, the local boiling heat transfer coefficient at the azimuthal angle of $90^{\circ}$ from the tube bottom can be regarded as the average of the coefficients regardless of the tube inclination angles. However, when the water is subcooled the location for the average heat transfer coefficient depends on the inclination angle and the heat flux. It is explained that the major mechanisms changing the heat transfer are closely related with the intensity of the liquid agitation and the generation of big size bubbles through bubble coalescence.

Numerical Analysis of Conjugate Heat Transfer for Various Ice-Ball Shapes (다양한 아이스 볼 형상에 대한 복합열전달의 수치해석)

  • Park, Seo Won;Kim, Myoung Soo;Jeon, Byoung Jin;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.605-612
    • /
    • 2016
  • In this study, numerical simulations were conducted for conjugate heat transfer around ice balls in an encapsulated ice thermal storage system. Four shapes of ice balls were modeled; the default one was a sphere, and the other three shapes were designed to enhance convective heat transfer through the ball surface. The flow around the ball was laminar, for which the Reynolds number was 300, and both forced and natural convections inside and outside the balls were considered. The simulations revealed that the magnitude of convective heat transfer for the different shapes decreased in the following order: bone, dimple, hole, and sphere. For the entire simulation, the maximum difference in the average temperatures of water inside the capsules was found to be $0.9^{\circ}C$. Therefore, it can be said that the effect of ice-ball shape on the performance of the ice thermal storage system is significant, considering that more than 0.3 million balls are used in this system.

A Study on Enhancing the Total Transfer Capability from a Voltage Stability Point of View Using SVC (SVC 적용에 의한 전압 안정도 측면에서의 융통전력 향상 방안에 대한 연구)

  • Lee, B.H.;Lee, S.J.;Kim, J.H.;Jang, K.H.;Kim, Y.H.;Kwak, N.H.;Ju, J.H.;Lee, J.L.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.90-92
    • /
    • 2002
  • The SVC(Static Var Compensator) resulted from the FACTS technology can generate or absorb reactive power rapidly so as to increase the transient and voltage stability. In this paper, the SVC is applied to the power system in order to improve the total transfer capability from a viewpoint of static voltage stability and the effects of application of the SVC to the power system are analyzed. The IPLAN, which is a high level language used with PSS/E program, is employed for determining the total transfer capability.

  • PDF

Numerical Analysis of Simultaneous Cooling Process of Upper and Lower Side of Running Hot Steel Strip (주행하는 고온 강재의 상하부 동시 냉각 과정 수치해석)

  • Kwon, Myeon Jae;Park, Il Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1051-1056
    • /
    • 2014
  • After hot rolling, a high-temperature steel plate with a temperature higher than $800^{\circ}C$ is rapidly cooled by multiple circular water jets. In this cooling process, because the temperature of the steel plate is much higher than the boiling point of the cooling water, film-boiling heat transfer occurs and a very thin steam layer forms between the plate surface and the cooling water. The steam layer acts as a thermal resistance that prevents heat transfer between the cooling water and the steel plate. In addition to the film-boiling heat transfer, complex physical phenomena such as the free-surface flow of residual water that accumulated on the material and the material's high-speed motion also occur in the cooling process. In this study, the simultaneous cooling process of the upper and lower sides of a running hot steel strip is investigated using a three-dimensional numerical model and the cooling performances and characteristics of the upper-side cooling and lower-side cooling are compared.

Perfonnance Evaluation of Swaged- and Extruded-type Heat Sinks Used in Inverter for Solar Power Generation (태양광 발전용 인버터 방열에 사용되는 압입형 및 압출형 히트싱크의 방열 성능 평가)

  • Kim, Jung Hyun;Lee, Gyo Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.933-940
    • /
    • 2013
  • In this study, we evaluated the heat release performance of two extruded-type and two swaged-type heat sinks used in an inverter for solar power generation. The number of fins and heat transfer areas of the two swaged-type heat sinks, namely S-62 and S-98, are 62 and 98 and $2.8m^2$ and $5.3m^2$, respectively. Those for the two extruded-type heat sinks, namely, E-38 and E-47, are 38 and 47 and $1.8m^2$ and $1.9m^2$, respectively. The heat release fractions of S-62 and S-98 were measured as 82.7 % and 86.3 %, respectively. Those of E-38 and E47 were measured to be 79.6 % and 81.6 %, respectively. In this experiment, despite the mass flow rates of air entering the heat sinks being almost the same, the heat release fractions increased with heat transfer area. Furthermore, despite S-62's heat transfer area being 47.4 % higher than that of E-47, its heat release fraction was higher by only 1.3 %. We believe that this indicates the better heat transfer property of the extruded-type heat sink. S-98's heat release is only 4.4 % higher than that of S-62, but its heat transfer area is 89.3 % higher; this suggests that its heat transfer area need to be optimized.

Voltammetric Investigation of Vitamin B_6 at a Glassy Carbon Electrode and Its Application in Determination

  • Wu, Yun-Hua;Song, Fa-Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2008
  • The voltammetic behavior of Vitamin B6 (VB6) was studied at a glassy carbon electrode in phosphate buffers using cyclic, linear sweep and differential pulse voltammetry. The oxidation process was shown to be irreversible over the entire pH range studied (4.0-10.0) and was adsorption controlled. The adsorption amount of VB6 on the glassy carbon electrode was examined by chronocoulometry and the value of n, product of transfer coefficient and number of electrons transferred in the rate determining step, was determined from Tafel plot. VB6 was determined by differential pulse voltammetry and the peak current was found linearly with its concentration in the range of 3 10-7-2 10-4 mol L-1. The detection limit was 1 10-7 mol L-1. The procedure was successfully applied for the assay of VB6 in tablets.

The effect of embryo catheter loading technique on the live birth rate

  • Omidi, Marjan;Halvaei, Iman;Mangoli, Esmat;Khalili, Mohammad Ali;Razi, Mohammad Hossein
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.42 no.4
    • /
    • pp.175-180
    • /
    • 2015
  • Objective: Embryo loading (EL) is a major step in embryo transfer (ET) and affect on the success of in vitro fertilization (IVF). This study aimed to compare the effect of two different EL techniques on the rates of pregnancy and delivery in IVF/ET cycles. Methods: 207 fresh ET and 194 Frozen-thawed ET (FET) cycles were included in this retrospective study. Two groups (A and B) were defined based on the EL technique used. In group A, the entire catheter was flushed with Ham's F-10 medium. The embryos were then drawn into the catheter using one air bracket. In group B, $70{\mu}L$ of air was aspirated into the syringe and the catheter was flushed using Ham's F10 medium. The medium, air, embryos, air, and finally another layer of medium were then sequentially drawn into the catheter. The main outcome measures were the pregnancy and delivery rates. Results: The groups did not differ with respect to the etiology of infertility, the source of spermatozoa, the quality of the embryos, the type of EL catheter, and the ease of transfer. The pregnancy rate was similar between two groups. In fresh ET cycles, a higher delivery rate was observed in group B than it group A (78.1% vs. 60%, p=0.1). In FET cycles, the rate of delivery was significantly higher in group B than in group A to a nonsignificant extent (88.9% vs. 58.8%, p=0.06). Conclusion: EL techniques did not have a significant impact on the delivery rate in either fresh or FET cycles.