• Title/Summary/Keyword: Tracking characteristic

Search Result 282, Processing Time 0.028 seconds

A Study on High-Efficiency MPPT Algorithm Based on P&O Method with Variable Step Size (가변 스텝 사이즈를 적용한 P&O 방식 기반의 고효율 MPPT 알고리즘 연구)

  • Kim, Bongsuck;Ding, Jiajun;Sim, Woosik;Jo, Jongmin;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, a maximum power point tracking (MPPT) algorithm based on the perturb and observe (P&O) method with variable step size is proposed to improve the dynamic response characteristic of MPPT, using the existing P&O method. The proposed algorithm, which we verified by simulation and experiment, can track the maximum power point (MPP) through duty control and consisted of three operation modes, namely, constant voltage mode, fast mode, and variable step mode. When the insolation is constant, the voltage variation of the operating point at the MPP is reduced through the step size reduction of the duty in the variable step mode. Consequently, the vibration of the operating point is reduced, and the power generation efficiency is increased. When the insolation changes, the duty and the photovoltaic (PV) voltage are kept constant through the constant voltage mode. The operating point then rapidly tracks the new MPP through the fast-mode operation at the end of the insolation change. When the MPP is reached, the operation is changed to the variable step mode to reduce the duty step size and track the MPP. The validity of the proposed algorithm is verified by simulation and experiment of a PV system composed of a PV panel and a boost converter.

Pattern Analysis of Maximum Power Point by means of Solar Cell Module Array Simulation (태양전지 모듈 어레이 시뮬레이션을 이용한 최대전력점 패턴분석)

  • Jeong, Ji-Won;Park, In-Gyu;Hwang, Kuk-Yeon;Ahn, Tae-Chon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.72-79
    • /
    • 2013
  • In the paper, a pattern analysis to decide whether the 1st local peak power point near open circuit voltage is the global peak power point or not, in case that the voltage and current at the 1st local peak power point are in a specific range, for Maximum Power Point Tracking on the photo voltaic power conversion system. When a solar cell panel array is shaded partially, multi-local peak power points can occur. That makes it hard to search the global peak power point. Through Tableau analysis using by piecewise linear solar cell model, V-I characteristic of a solar cell panel array circuit when partial shading problem happens, is simulated. The global peak power and the local peak power points is confirmed by simulations. Voltage and current values and patterns of V-I characteristic are analyzed. The generating efficiency of the solar cell panel array is improved, when the solar cell panel array circuit is operated at the power point estimated by setting up specific range.

A Study on the Analysis of Gaze Characteristic of The Villa Savoye - Based on the Difference between Architecture Major Group and Non-Architecture Major Group (빌라 사보아의 건축입면 주시특성 연구 - 건축 전공자와 비전공자의 차이를 중심으로)

  • Cho, Hyeong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.724-731
    • /
    • 2016
  • The purpose of this study was to determine what rules or patterns exist when people gaze at a villa savoye, which is probably Le Corbusier's best known building, using eye-movement tracking techniques. Villa savoye was designed, addressing his emblematic "Five Points", such as pilotis, functional roofs, free floor plans, long horizontal windows, and freely-designed facades. This study examined how the villa savoye's facade image is formed in an objective manner. This study selected a total of 56 test subjects, and showed them an image of a villa savoye. Using eye-movement tracking tools, this study recorded where they mostly gazed at when seeing the building. In addition, an experiment was carried out to test the different points of view, relating to visual attention, between the two groups with different levels of knowledge in architecture. To analyze the data, the Gaze Frequency was used as the key indicator. The results showed that the subjects have a higher degree of attention to either the door or window in general than in former studies. The architecture major group showed that they gazed the experiment image more evenly.

The effect of preference color of children's hospital lobby on the visual attention (어린이병원 로비공간에서 선호 색채가 시지각 주의집중에 미친 영향)

  • Cho, Eun Kil;Son, Kwang Ho
    • Korea Science and Art Forum
    • /
    • v.23
    • /
    • pp.347-358
    • /
    • 2016
  • The design of children's hospitals is highly dependent on color schemes. As a space shared together by both adults and children, the design of children's hospitals require color coordination that takes account of the users' characteristics. However, because the majority of prior research on color perception has focused overly on the emotional aspects, there is a necessity for more rational and scientific analyses to identify the characteristics of the visual perception of colors. Adopting this perspective in analyzing the characteristics of the visual perception of colors, this study aims to move beyond the abstract to focus on more objective methods, such as eye-tracking experiments, to examine the characteristics of hospital visitors' visual attention with respect to colors. Visual perception tracking experiment was conducted on the 2 chosen experimental images with a target group made up of adults and children, the following results were found. Firstly, spaces created with the preference colors of the different groups were found to develop a characteristic of developing higher attention. Secondly, observing the common tendencies for attention for adults and children, the highest region for visual concentration was formed towards the middle, as attention progresses to lower stages visually focused area changes in the order of upper-middle, left and right, and lower regions and edge regions show characteristics of not triggering attention Thirdly, it is understood that children's level of attention drops a lot faster than adults when identifying space therefore it is suspected that children need more elaborate color coordination than adults.

Resistive Current Mode Control for the Solar Array Regulator of SPACE Power System (인공위성 시스템을 위한 태양전지 전력조절기의 저항제어)

  • Bae, Hyun-Su;Yang, Jeong-Hwan;Lee, Jae-Ho;Cho, Bo-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.535-542
    • /
    • 2006
  • A large signal stability analysis of the solar array regulator system is performed to facilitate the design and analysis of a Low-Earth-Orbit satellite power system. The effective load characteristics of every controllable method in the solar array system are classified to analyze the large signal stability. Then, using the state plane analysis technique, the stability of various equilibrium points is analyzed. A nonlinear transformation algorithm, which changes the effective load characteristic of the solar array regulator as constant resistive load, is also proposed for the large signal stability. The proposed resistive current mode control system can control the solar array output for purposes such as peak power tracking control and battery charging control. For the verification of the proposed large signal analysis and resistive current mode control, a solar array regulator system consisting of two 100W parallel module buck converters has been built and tested using a real 200W solar array.

Direct Numerical Analysis of $CO_2$ degassing process in ${\mu}DMFC$ (마이크로 DMFC 에서 $CO_2$ degassing 과정의 직접 수치 해석)

  • Shin, Seung-Won;Shim, Jung-Ik;Wi, Wan-Seok;Jo, Sung-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2648-2653
    • /
    • 2007
  • Recently, increasing demand on not only lighter but also extremely mobile battery make micro fuel cell device very attractive alternative. By reducing the size of fuel cell, surface tension becomes dominant factor with minor gravitational effect. Therefore, it is very difficult to detach the $CO_2$ bubble generating on a cathode side in ${\mu}DMFC$ (micro direct methanol fuel cell). The degassing of a $CO_2$ bubble has drawn quite attention especially for ${\mu}DMFC$ due to its considerable effect on overall machine performance. Our attention has been paid to the dynamic behavior of immiscible bubble attached to the one side of the wall on 2D rectangular channel subject to external shear flow. We use Level Contour Reconstruction Method (LCRM) which is simplified version of front tracking method to track the bubble interface motion. Effects of Reynolds number, Weber number, advancing/receding contact angle and property ratio on bubble detachment characteristic has been numerically identified.

  • PDF

Precision position control of piezoelectric actuator (압전액추에이터 정밀 위치 제어)

  • Yun S.;Kim C.Y.;Ham Y.B.;Jo J.;Ahn B.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.531-536
    • /
    • 2005
  • The purpose of this paper is to improve the hysteresis characteristics of a stack type piezoelectric actuator using system identification and tracking control. Recently, several printing methods that cost less and are faster than previous semiconductor processes have been developed for the production of electric paper and RFID. The system proposed in this study prints by spraying the molten metal, and consists of a nozzle, heating furnace, operating actuator, and an XYZ 3-axis stage, As an operating system, the piezoelectric(PZT) method has very valuable uses. However, the PZT actuator has a very big hysteresis characteristic due to the ferroelectric characteristics of the PZT element. This causes problems in the system position control characteristics and deteriorates the performance of the system. In this study, an investigation was conducted to improve the hysteresis characteristics of the PZT actuator that has an output displacement for the input voltage. The study proposed a inverse hysteresis model, a mathematic modeling method that can express the geometric relationship between voltage and displacement, in order to reduce the hysteresis of the PZT actuator. In addition, system identification and PID control methods were examined. Also, it was confirmed that the proposed control strategy gives good precision position control performance.

  • PDF

The Characteristic of the Performance of the Bypass Diode with Composition Change of the String in Si-PV Module (결정질 PV 모듈의 string 구성에 따른 바이패스 다이오드 동작 특성)

  • Ji, Yang-Geun;Kong, Ji-Hyun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2212-2217
    • /
    • 2010
  • Previous studies have been focused on the voltage of Bypass diode and Isc(Short Circuit Current) of the influenced solar cell. The Bypass diode starts working when it gets the reverse applied voltage. Previous studies have only concentrated on Isc of the influenced solar cell and Imp of PV module to explain the bypassing performance. PV module is usually working together with inverter having MPPT(Maximum Power Point Tracking) function for best performance. bypassing point is regulated by MPPT function of inverter. In this paper, simulation results of Bypass diode in PV module have been analyzed to represent the relationship of the bypassing point with the composition of PV module. From the results, the more cells are connected with each string, the earlier bypassing performance happens under the fixed number of strings. As diode groups increase or irradiation decreases, the bypassing performance starts fast.

A Characteristic Study on the Dye-Sensitized Solar Cell by the Shadow Effect (그림자 효과에 의한 염료감응형 태양전지의 특성연구)

  • Kim, Hee-Je;Lee, Jeong-Gee;Lee, Kyung-Jun;Prabakar, Prabakar;Sin, Dong-Seoul;Chae, Won-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.144-151
    • /
    • 2010
  • The shadowing effects lead to the serious power losses of the PV module. The shadowing effects are caused by several factors such as leafs, dust, antenna and clouds. The dye-sensitized solar cells are more economical than the conventional silicon solar cell that's why the dye-sensitized solar cells are recently focused on. We carried out research on the efficiency of the dye-sensitized solar cell depending on the level of shadow changing the formula of the circuit. The research on the efficiency of the large dye-sensitized solar cell depending on the level of shadow focused on commercialization was carried out. As the results, it is known that the series and parallel connection method is the best choice for the least losses of PV module assemblies. It is especially known that one more series connection is the best choice for the least losses about shadowing effects and current losses in the series and parallel connection.

The Design of Robust DSC-PLL under Distorted Grid Voltage Contained Unbalance on Frequency Variation (주파수 변동시 불평형 전압에 강인한 DSC-PLL 설계 연구)

  • Lee, Jae Do;Cha, Han Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1447-1454
    • /
    • 2018
  • In this paper, the design of robust DSC-PLL(Delayed Signal Cancellation Phase Locked Loop) is proposed for coping with frequency variation. This method shows significant performance for detection of fundamental positive sequence component voltage when the grid voltage is polluted by grid unbalance and frequency variation. The feedback frequency estimation of DSC-PLL is tracking the drift in the phase by unbalance and frequency variation. The robust DSC PLL is to present the analysis on method and performance under frequency variations. These compensation algorithms can correct for discrepancies of changing the frequency within maximum 193[ms] and improve traditional DSC-PLL. Linear interpolation method is adopted to reduce the discretized errors in the digital implementation of the PLL. For verification of robust characteristic, PLL methods are implemented on FPGA with a discrete fixed point based. The proposed method is validated by both Matlab/Simulink and experimental results based on FPGA(XC7Z030).