Abstract
Previous studies have been focused on the voltage of Bypass diode and Isc(Short Circuit Current) of the influenced solar cell. The Bypass diode starts working when it gets the reverse applied voltage. Previous studies have only concentrated on Isc of the influenced solar cell and Imp of PV module to explain the bypassing performance. PV module is usually working together with inverter having MPPT(Maximum Power Point Tracking) function for best performance. bypassing point is regulated by MPPT function of inverter. In this paper, simulation results of Bypass diode in PV module have been analyzed to represent the relationship of the bypassing point with the composition of PV module. From the results, the more cells are connected with each string, the earlier bypassing performance happens under the fixed number of strings. As diode groups increase or irradiation decreases, the bypassing performance starts fast.