• Title/Summary/Keyword: Trace detect

Search Result 118, Processing Time 0.03 seconds

A Study of Automatic detection for the Lung Boundary using Lung Apex Region Matching of Chest X-Ray Image (흉부 방사선 영상의 정점영역 매칭을 통한 허파영역 자동검출에 관한 연구)

  • Kim, Sang-jin;Kim, Yong-Man;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.217-226
    • /
    • 1990
  • This paper presents a new algorithm that extracted lung region in X-ray and enhanced the region. With a lung region that was extracted by histogram threshold value, it was diffi cult to detect perfect lung boundary. Therefore we presented perfect lung boundary detection method using apex detection and apex region restoration. Also, by applying modified equalization algorithm and presented function to inside of lung region, we want to give help to automatic diagnosis In X-ray chest image. Presented main line trace algorithm gave good result in detection of lung boundary And, as apex detection method using lung row and column gray level average value found more correct place of lung than the rpethod of prior algorithm, we succeeded perfect lung region detection, Also, presented function that had lung region's gray level distribution characteristic was very effective to image enhancement.

  • PDF

Study of Short-Term Sunspot Motion toward Flare Onset Prediction

  • Suematsu, Yoshinori;Yatini, Clara Y.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.87.2-87.2
    • /
    • 2011
  • Proper motion of sunspots in several active regions was studied to detect their indicator on flare onset, using data from the Solar Flare Telescope at Mitaka (four flaring active regions), TRACE (e.g. NOAA 0424, M1.7 flare on 5 Aug. 2003) and Hinode (e.g. NOAA 10930, X3.4 flare on 13 Dec. 2006). The proper motion of individual sunspots was derived using a local correlation tracking method. As a result, we found that the sunspots that are located under or close to a part of chromospheric flaring patches showed a change in their moving direction prior to the flare onset. The change in their movements took place a half to two hours before the flare onset. On the other hand, sunspots in non-flaring areas or non-flaring active regions did not show this kind of change. It is likely, therefore, that if a sunspot shows the particular movement, a chromospheric flare is to occur in its nearby region. In the most active regions, the part of flare ribbons was located on an emerging bipolar pair of sunspots. The disturbance in the usual motion of the bipolar sunspots and in other sunspots as well can be interpreted as a sign of magnetic shear development leading to final magnetic energy buildup before its sudden release. We suggest that the change in sunspot motion in a short time scale prior to the flare onset can be regarded as a good indicator in predicting the onset timing and location of chromospheric flares.

  • PDF

Secondary Ion Mass Spectrometry : Theory and Recent trends (이차이온질량분석기의 원리와 분석법 동향)

  • Byeon, Mirang;Kim, Da Young;Hong, Tae Eun
    • Ceramist
    • /
    • v.22 no.4
    • /
    • pp.357-367
    • /
    • 2019
  • Secondary Ion Mass Spectrometry(SIMS) is an analytical method that measures the distribution and concentration of elements or compounds by analyzing the mass of secondary ions released by irradiating ion beams with energy of hundreds eV to 20 keV on the sample surface. Unlike other similar analytical instruments, SIMS directly detect the elemental ions that constitute a sample, allowing you to accurately identify components and obtain concentration information in the depth direction. It is also a great feature for measuring isotopes and analyzing light elements, especially hydrogen. In particular, with the development of materials science, there is an increasing demand for trace concentration analysis and isotope measurements in the micro-regions of various materials. SIMS has a short history compared to other similar methods; nevertheless, SIMS is still advancing in hardware and is expected to contribute to the development of materials science through research and development of advanced analytical techniques.

Application of the Ultrasonic Detection System for the Power Transformer (전력용 변압기 초음파 측정시스템 적용)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.553-557
    • /
    • 2005
  • This paper describes the application results of an ultrasonic detection system for the power transformer. The ultrasonic detection system with 6 sensors was applied to detect partial discharge in a 154kV transformer with a dangerous levels of $C_{2}H_{2},\;C_{2}H_4$ and $CH_{4}$ gases. The ultrasonic detection tests were carried out 2 times, respectively, to confirm the existence and location of the partial discharge in the transformer. As a result of internal inspection, the arc trace between the pressure ring and core due to the partial discharge was found at the estimated position based on the amplitude and arriving time of the ultrasonic signals. Therefore, it was verified that the ultrasonic detection system is effective as a preventive diagnosis method for the power transformer. Also, the reliability of the ultrasonic detection system in detecting partial discharges in the transformer was also confirmed. It is expected, therefore, that the ultrasonic detection system will have beneficial effects on applications and verifications in detecting partial discharges for the power transformer.

Immunoassay of haptoglobin and transferrin with proteinG-containing QCM sensor chip and unpurified antiserum (Protein G를 포함하는 수정미소저울 센서 칩과 정제되지 않은 항혈청을 이용한 헵토글로빈과 트랜스페린의 면역분석)

  • Ha, In-Young;Choi, Suk-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.380-386
    • /
    • 2008
  • Quartz crystal microbalance immunosensor has a capacity to perform a label-free and real time detection of a trace amount of analyte through the specific interaction between antibody and antigen. However, immobilization of antibody molecules on the sensor surface is a troublesome procedure for researchers who are not experienced in chemistry. Protein G has a specific affinity to antibody and would serve as a capturing agent for antibody when immobilized on the sensor surface. In this work, we prepared a protein G sensor chip by immobilizing protein G on the surface of quartz crystal microbalance and examined its capability to detect human haptoglobin or human transferrin with unpurified corresponding antiserum. Specific and dose dependent response was observed when the protein G chip was used for detection of antigens after saturated with antiserum. We also verified several advantageous aspects of the protein G chip such as improved flexibility and sensitivity.

Deep Learning based Rapid Diagnosis System for Identifying Tomato Nutrition Disorders

  • Zhang, Li;Jia, Jingdun;Li, Yue;Gao, Wanlin;Wang, Minjuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.4
    • /
    • pp.2012-2027
    • /
    • 2019
  • Nutritional disorders are one of the most common diseases of crops and they often result in significant loss of agricultural output. Moreover, the imbalance of nutrition element not only affects plant phenotype but also threaten to the health of consumers when the concentrations above the certain threshold. A number of disease identification systems have been proposed in recent years. Either the time consuming or accuracy is difficult to meet current production management requirements. Moreover, most of the systems are hard to be extended, only detect a few kinds of common diseases with great difference. In view of the limitation of current approaches, this paper studies the effects of different trace elements on crops and establishes identification system. Specifically, we analysis and acquire eleven types of tomato nutritional disorders images. After that, we explore training and prediction effects and significances of super resolution of identification model. Then, we use pre-trained enhanced deep super-resolution network (EDSR) model to pre-processing dataset. Finally, we design and implement of diagnosis system based on deep learning. And the final results show that the average accuracy is 81.11% and the predicted time less than 0.01 second. Compared to existing methods, our solution achieves a high accuracy with much less consuming time. At the same time, the diagnosis system has good performance in expansibility and portability.

Design and implementation of IoT platform for collecting and managing the SmartFactory environment information

  • Kim, SungJin;Ra, SangYong;Kim, HwanSeog;Choi, JaeHong;Lee, JunDong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.6
    • /
    • pp.109-115
    • /
    • 2019
  • Smart Factory is a part of and a key point of the 4th industrial revolution. It performs optimization from the whole viewpoint, using comprehensive data of the post-process data by utilizing various sensors, controllers, and mobile devices beyond the existing factory automation level. In this paper, we design and implement an IoT platform that can detect the safety factors of the workers, the environmental factors of the factory, and real time monitoring at the control center, among the fields to implement smart factory. To accomplish this, we construct a monitoring device that provides sensor information control, server transmission of sensor information, and visualization of collected information. By using this system, it is possible to maintain the temperature and humidity for the optimum working environment in the factory. and also, By using the beacon, it is possible to measure the working time of the worker and trace the position.

Assessment of the Purity of Emodin by Quantitative Nuclear Magnetic Resonance Spectroscopy and Mass Balance

  • Park, Sojung;Choi, Yu-Jin;Do, Giang Hoang;Seo, Eun Kyoung;Hyun, Seunghun;Lee, Dongho
    • Natural Product Sciences
    • /
    • v.25 no.3
    • /
    • pp.222-227
    • /
    • 2019
  • Quantitative nuclear magnetic resonance (qNMR) is a well-established method adopted by international pharmacopoeia for quantitative and purity analyses. Emodin is a type of anthraquinone, well known as the main active component of Fabaceae, Polygonaceae and Rhamnaceae. Purity analysis of emodin is usually performed by using the high-performance liquid chromatography (HPLC)-UV method. However, it cannot detect impurities such as salts, volatile matter, and trace elements. Using the qNMR method, it is possible to determine the compound content as well as the nature of the impurities. Several experimental parameters were optimized for the quantification, such as relaxation delay, spectral width, number of scans, temperature, pulse width, and acquisition time. The method was validated, and the results of the qNMR method were compared with those obtained by the HPLC and mass balance analysis methods. The qNMR method is specific, rapid, simple, and therefore, a valuable and reliable method for the purity analysis of emodin.

Real-time Rebar Injection Endpoints Tracking Method to Improve the Straightness of Rebars (철근 직진도 개선을 위한 실시간 철근 사출 끝점 추적 방법)

  • Kim, Jong-Sik;Kang, Dae-Seong
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.8
    • /
    • pp.75-83
    • /
    • 2019
  • In this paper, we propose a method that can detect and trace the end point of real - time reinforcement steel to various environmental conditions of industrial field by using Median flow and Depth information. We proposed a method to derive two steel end points by using Median filter, Binarization, Morphology, and Blob algorithm on image depth information. The coordinates of the final position were determined by comparing the coordinates of the reinforcement steel endpoints detected in the Depth image and the position tracking coordinates of the reinforcement steel using Median Flow. As a result, when the existing Median Flow method was used, the success rate of the final position determination of reinforcement steel of 75% was increased to 95% when the Depth of reinforcement steel was used.

Determination of pseudoephodrine, dextromethorphan and their metabolites in human urine by gas chromatography - mass spectrometry (GC/MS를 이용한 소변 중 Pseudoephedrine과 Dexrormethorphan 및 대사체의 동시분석)

  • Lee, Won Woong;Ahn, Sung-Ho;Lee, Sung-Woo;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.315-322
    • /
    • 2007
  • This study has been described the metabolism and excretion in a healthy male urine collected for 24 hr after oral administration of a complex (pseudoephedrine and dextromethorphan). To detect the trace amounts of parent drugs and their metabolites, acid-hydrolyzed urine was extracted and derivatized with MSTFA and MBTFA followed by gas chromatography/mass spectrometric analysis. Two parent drugs and their metabolites were tentatively identified as their derivatives based on the mass spectral interpretation and compared with previous reports. In addition, the time profile of urinary excretion rate for parent drugs and metabolites was studied. On the basis of metabolites identified and excretion rate, the metabolic pathways of both drugs are suggested.