• 제목/요약/키워드: Total system and Sub system

검색결과 686건 처리시간 0.036초

Mg0.1Zn0.9O/ZnO 활성층 구조의 박막트랜지스터 연구 (A Study of Thin-Film Transistor with Mg0.1Zn0.9O/ZnO Active Structure)

  • 이종훈;김홍승;장낙원;윤영
    • 한국전기전자재료학회논문지
    • /
    • 제27권7호
    • /
    • pp.472-476
    • /
    • 2014
  • We report the characteristics of thin-film transistor (TFT) to make the bi-channel structure with stacked $Mg_{0.1}Zn_{0.9}O$ (Mg= 10 at.%) and ZnO. The ZnO and $Mg_{0.1}ZnO_{0.9}O$ thin films were deposited by radio frequency (RF) co-sputter system onto the thermally oxidized silicon substrate. A total thickness of active layer was 50 nm. Firstly, the ZnO thin films were deposited to control the thickness from 5 nm to 30 nm. Sequentially, the $Mg_{0.1}ZnO_{0.9}O$ thin films were deposited to change from 45 nm to 20 nm. The bi-layer TFT shows more improved properties than the single layer TFT. The field effect mobility and subthreshold slope for $Mg_{0.1}ZnO_{0.9}O$/ZnO-TFT are $7.40cm^2V^{-1}s^{-1}$ and 0.24 V/decade at the ZnO thickness of 10 nm, respectively.

Oscillometry-Defined Small Airway Dysfunction in Patients with Chronic Obstructive Pulmonary Disease

  • Amit K. Rath;Dibakar Sahu;Sajal De
    • Tuberculosis and Respiratory Diseases
    • /
    • 제87권2호
    • /
    • pp.165-175
    • /
    • 2024
  • Background: The prevalence of small airway dysfunction (SAD) in patients with chronic obstructive pulmonary disease (COPD) across different ethnicities is poorly understood. This study aimed to estimate the prevalence of SAD in stable COPD patients. Methods: We conducted a cross-sectional study of 196 consecutive stable COPD patients. We measured pre- and post-bronchodilator (BD) lung function and respiratory impedance. The severity of COPD and lung function abnormalities was graded in accordance with the Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines. SAD was defined as either difference in whole-breath resistance at 5 and 19 Hz > upper limit of normal or respiratory system reactance at 5 Hz < lower limit of normal. Results: The cohort consisted of 95.9% men, with an average age of 66.3 years. The mean forced expiratory volume 1 second (FEV1) % predicted was 56.4%. The median COPD assessment test (CAT) scores were 14. The prevalence of post-BD SAD across the GOLD grades 1 to 4 was 14.3%, 51.1%, 91%, and 100%, respectively. The post-BD SAD and expiratory flow limitation at tidal breath (EFLT) were present in 62.8% (95% confidence interval [CI], 56.1 to 69.9) and 28.1% (95% CI, 21.9 to 34.2), respectively. COPD patients with SAD had higher CAT scores (15.5 vs. 12.8, p<0.01); poor lung function (FEV1% predicted 46.6% vs. 72.8%, p<0.01); lower diffusion capacity for CO (4.8 mmol/min/kPa vs. 5.6 mmol/min/kPa, p<0.01); hyperinflation (ratio of residual volume to total lung capacity % predicted: 159.7% vs. 129%, p<0.01), and shorter 6-minute walk distance (367.5 m vs. 390 m, p=0.02). Conclusion: SAD is present across all severities of COPD. The prevalence of SAD increases with disease severity. SAD is associated with poor lung function and higher symptom burden. Severe SAD is indicated by the presence of EFLT.

서울시 미세입자(PM2.5)의 호흡기질환 사망과의 연관성 연구 (Respiratory Health Effects of Fine Particles(PM2.5) in Seoul)

  • 강충민;박성균;선우영;강병욱;이학성
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.554-563
    • /
    • 2006
  • Numerous epidemiological studies have shown stronger associations between $PM_{2.5}$ and both mortality and morbidity than $PM_{10}$. The association of $PM_{2.5}$ with respiratory mortality was examined in Seoul, during the period of $1996{\sim}2002$. Because $PM_{2.5}$ data were available for only 10% of this time period, a prediction regression model was developed to estimate $PM_{2.5}$ concentration. Death count due to respiratory-related diseases(total respiratory mortality; ICD-10, J00-J98) and death counts(cause-specific mortality) due to pneumonia(ICD-10, J12-J18), COPD(ICD-10, J40-J44) and asthma(ICD-10, J45-J46) were considered in this study. Averaged daily mortality was 5.6 for total respiratory mortality and 1.1 to 1.6 for cause-specific mortality. Generalized additive Poisson models controlling for confounders were used to evaluate the acute effects of particle exposures on total respiratory mortality and cause-specific mortality. An IQR increase in 5-day moving average of $PM_{2.5}(22.6{\mu}g/m^3)$ was associated with an 8.2%(95% CI: 4.5 to 12.1%) increase in total respiratory mortality The association of $PM_{2.5}$ was stronger for the elderly ($\geq$65 years old, 10.1%, 95% CI: 5.8 to 14.5%) and for males(8.9%, 95% CI: 2.1 to 11.3%). A $10{\mu}g/m^3$ increase in 5-day moving average of $PM_{2.5}$ was strongly associated with total respiratory mortality in winter(9.5%, 95% CI: 6.6 to 12.4%), followed by spring(3.1%, 95% CI: -1.2 to 7.5%), which was a different pattern with the finding in North American cities. However, our results are generally consistent with those observed in recent epidemiological studies, and suggest that $PM_{2.5}$ has a stronger effect on respiratory mortality in Seoul.

Analysis on the Formation of Li4SiO4 and Li2SiO3 through First Principle Calculations and Comparing with Experimental Data Related to Lithium Battery

  • Doh, Chil-Hoon;Veluchamy, Angathevar;Oh, Min-Wook;Han, Byung-Chan
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권3호
    • /
    • pp.146-151
    • /
    • 2011
  • The formation of Li-Si-O phases, $Li_4SiO_4$ and $Li_2SiO_3$ from the starting materials SiO and $Li_2O$ are analyzed using Vienna Ab-initio Simulation (VASP) package and the total energies of Li-Si-O compounds are evaluated using Projector Augmented Wave (PAW) method and correlated the structural characteristics of the binary system SiO-$Li_2O$ with experimental data from electrochemical method. Despite $Li_2SiO_3$ becomes stable phase by virtue of lowest formation energy calculated through VASP, the experimental method shows presence of $Li_4SiO_4$ as the only product formed when SiO and $Li_2O$ reacts during slow heating to reach $550^{\circ}C$ and found no evidence for the formation of $Li_2SiO_3$. Also, higher density of $Li_4SiO_4$(2.42 g $ml^{-1}$) compared to the compositional mixture $1SiO_2-2Li_2O$ (2.226 g $ml^{-1}$) and better cycle capacity observed through experiment proves that $Li_4SiO_4$ as the most stable anode supported by better cycleabilityfor lithium ion battery remains as paradox from the point of view of VASP calculations.

18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구 (Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day)

  • 함준철;박민수;반영각;임한상;김재삼
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.68-72
    • /
    • 2014
  • 핵의학 검사는 반감기로 인한 동위원소의 잔류로 당일에 두 가지 검사를 시행하는데 어려움이 있다. 본 연구는 $^{18}F$-FDG와 $^{99m}TcO_4{^-}$의 상호 영향을 연구함으로써 당일 검사를 진행할 경우 고려될 사항에 대해 알아보고자 한다. NEMA-1994 Phantom을 이용하여 세 번의 실험을 진행했다. 첫 실험은 $^{99m}TcO_4{^-}$을 HOT과 BKG 비 4:1로 만들어 GE사의 INFINIA 장비로 SPECT를 시행하였고, BKG 영역에 $^{18}F$-FDG 37 MBq을 주입 후 동일 조건으로 60분에 1회씩 13회 Scan 했다. 두 번째는 $^{18}F$-FDG를 HOT과 BKG 비 4:1 로 만들어 GE사의 PET/CT Discovery 600 에서 Scan 하였고, BKG 영역에 $^{99m}TcO_4{^-}$을 148 MBq 주입 후 동일 조건으로 60분에 1회씩 6회 Scan 했다. 마지막 실험은 $^{18}F$-FDG를 HOT과 BKG 비 4 : 1로 만들고 1 Bed Scan 후 $^{99m}TcO_4{^-}$을 148 MBq 및 296 MBq씩 증가 시키며 같은 조건으로 1 Bed Scan했다. HOT과 BKG 영역의 비, CNR 혹은 SNR 그리고 총 획득 계수를 측정 후 비교 했다. $^{18}F$-FDG는 SPECT 시행 시 비율 및 CNR에 유의한 차이를 보였다(p>0.05). $^{99m}TcO_4{^-}$는 PET/CT 시행 시 비율 및 SNR이 유의한 차이를 보이지 않았다(p<0.05). $^{99m}TcO_4{^-}$이 PET/CT 검사의 Total Counts를 감소시킨다는 결과를 획득했다. PET/CT 검사를 한 경우 12시간 까지도 $^{99m}TcO_4{^-}$을 이용한 검사에 영향을 미칠 수 있으며, $^{99m}TcO_4{^-}$를 먼저 시행한 경우에는 PET/CT 검사에 SUV 및 SNR에 영향은 없지만 검출 효율을 감소시켰다. 당일 검사 시에는 $^{99m}TcO_4{^-}$을 이용한 검사를 먼저 진행하고 PET/CT의 검사 시간을 늘려 검출 효율을 보완하는 방법을 권장하고자 한다.

  • PDF

DB운영 데이터 분석을 통한 G2B 시스템 평가 사례 (A Case of Evaluation of the G2B System by Analysing Operational DB Data)

  • 임규건;이대철
    • 한국IT서비스학회지
    • /
    • 제11권2호
    • /
    • pp.243-258
    • /
    • 2012
  • The G2B system is one of the important information systems in the e-government implementation. It is difficult to measure the cost reduction effect of the system introduction because there are many participants in the complex procurement processes. Previous approaches of the performance evaluation of such processes have been based on conducting some surveys and interviews with statistical methods. Therefore there have been some limitations in the verification of feasibility. Therefore this study tries to suggest a case of performance evaluation about the cost reduction in using of the G2B system by analyzing operational DB data from the G2B system. This study analyzed the procurement processes of G2B system according to 'goods' and 'facilities/services' and classified the procurement processes into 12 sub-processes. By developing an evaluation model for the cost reduction of e-procurement, we derived the whole cost reduction effect was 8,000 billon Won for the use of Korea KONEPS G2B system in 2008. Specially the cost reduction in the private sector was 6,600 billion Won. It was mainly due to the decrease of the offline visits to the related organizations to participate a bidding process. Moreover, the cost reduction of using shopping mall was 1,000 billion Won among the total 1,400 billion Won in the whole public sector. The main contribution of this paper is to show the more objective evaluation result of the use of e-procurement, which verifies the necessity of G2B system.

CT실에서 무연보드 차폐체의 X선 차폐능력 평가 (Evaluation of the X-ray Shielding Ability of Lead Free Board Shielding in the CT Room)

  • 김성준;한태호;이효원;오유환;김승철;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권4호
    • /
    • pp.249-254
    • /
    • 2024
  • This study compared the X-ray shielding abilities of the shields using Computed Radiography(CR) System after manufacturing a lead-free boards using gypsum and BaSO4, an eco-friendly X-ray shielding material. Total six lead-free boards were manufactured with BaSO4 concentrations of 25 %, 50 % and thickness of 10 mm, 15 mm, 20 mm respectively, and additional thickness of 1.0 mm, 1.5 mm, 2.0 mm leads were prepared. In the experiment, Nine shields were placed on the Image Plate and placed in a Computed Tomography(CT) Room where CT scans were performed for 2 weeks. After that, the X-ray image of the shields were obtained through CR Reader, and Pixel Value(PV) were measured to evaluated the X-ray shielding abilities of the lead-free shields. The criterion for evaluating the shields was determined by comparing PV of lead-free board to that of the 1.5 mm thickness lead used in the CT rooms. As a result of the experiment, the PV of the lead-free boards within 25 % of the BaSO4 concentration and within 10 mm of the thickness were not enough to be used as X-ray shields in the CT Room because they did not reach the PV of the 1.5 mm thickness lead. BaSO4 concentration of 50 % at 20 mm thickness showed PV of 1.5 mm lead thickness or more indicating that it has an X-ray shielding ability to replace lead in the CT room

사용자 감정 예측을 통한 상황인지 추천시스템의 개선 (Improvement of a Context-aware Recommender System through User's Emotional State Prediction)

  • 안현철
    • Journal of Information Technology Applications and Management
    • /
    • 제21권4호
    • /
    • pp.203-223
    • /
    • 2014
  • This study proposes a novel context-aware recommender system, which is designed to recommend the items according to the customer's responses to the previously recommended item. In specific, our proposed system predicts the user's emotional state from his or her responses (such as facial expressions and movements) to the previous recommended item, and then it recommends the items that are similar to the previous one when his or her emotional state is estimated as positive. If the customer's emotional state on the previously recommended item is regarded as negative, the system recommends the items that have characteristics opposite to the previous item. Our proposed system consists of two sub modules-(1) emotion prediction module, and (2) responsive recommendation module. Emotion prediction module contains the emotion prediction model that predicts a customer's arousal level-a physiological and psychological state of being awake or reactive to stimuli-using the customer's reaction data including facial expressions and body movements, which can be measured using Microsoft's Kinect Sensor. Responsive recommendation module generates a recommendation list by using the results from the first module-emotion prediction module. If a customer shows a high level of arousal on the previously recommended item, the module recommends the items that are most similar to the previous item. Otherwise, it recommends the items that are most dissimilar to the previous one. In order to validate the performance and usefulness of the proposed recommender system, we conducted empirical validation. In total, 30 undergraduate students participated in the experiment. We used 100 trailers of Korean movies that had been released from 2009 to 2012 as the items for recommendation. For the experiment, we manually constructed Korean movie trailer DB which contains the fields such as release date, genre, director, writer, and actors. In order to check if the recommendation using customers' responses outperforms the recommendation using their demographic information, we compared them. The performance of the recommendation was measured using two metrics-satisfaction and arousal levels. Experimental results showed that the recommendation using customers' responses (i.e. our proposed system) outperformed the recommendation using their demographic information with statistical significance.

다지지점 지진입력에 대한 현수교의 지반-구조물 상호작용해석 (Soil-Structure Interaction Analysis of Suspension Bridge for Multiple-Support Seismic Input)

  • 김재민;이명규;신용우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.182-189
    • /
    • 2003
  • Member actions of long-span suspension bridge due to multiple-support motion are generally larger than those for synchronous support motion frequently employed in aseismic design of a conventional structure. In this study, all the sources of the asynchronous support motion are considered including the loss of coherence and the soil-structure interaction as well as the time delay due to wave propagation of seismic waves. The substructure technique analyzing total soil-foundation-structure system as a superposition of two sub-structures including soil-foundation system and structure itself is employed for the seismic response analysis of the suspension bridge. Finally, an application example is presented to demonstrate applicability of the proposed methodology.

  • PDF

BCAT구조 DRAM의 패싱 워드 라인 유도 누설전류 분석 (Analysis of Passing Word Line Induced Leakage of BCAT Structure in DRAM)

  • 김수연;김동영;박제원;김신욱;임채혁;김소원;서현아;이주원;이혜린;윤정현;이영우;조형진;이명진
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.644-649
    • /
    • 2023
  • DRAM(Dynamic Random Access Memory) 스케일링 과정에서 발생하는 셀간 거리의 감소에 따라 STI(Shallow Trench Isolation)두께 감소는 문턱이하 누설이 증가되는 패싱워드라인 효과를 유발한다. 인접한 패싱워드라인에 인가된 전압으로 인한 문턱이하누설 전류의 증가는 데이터 보존시간에 영향을 주며, 리프레시의 동작 횟수가 증가되어 DRAM의 소비 전력을 증가시키는 요인이 된다. 본 논문에서는 TCAD Simulation을 통해 패싱워드라인 효과에 대한 원인을 확인한다. 결과적으로, 패싱워드라인 효과가 발생하는 DRAM 동작상황을 확인하고, 이때 패싱워드라인 효과로 인해 전체 누설전류의 원인에 따른 비중이 달라지는 것을 확인하였다. 이를 통해, GIDL(Gate Induced Drain Leakage)에 의한 누설전류뿐만 아니라 문턱이하 누설전류를 고려의 필요성을 확인하며 이에 따른 DRAM 구조의 개선 방향의 지침이 될 수 있다.