• Title/Summary/Keyword: Total flow velocity

Search Result 381, Processing Time 0.024 seconds

Groundwater flow Analysis Using MODFLOW in the Tunnel (MODFLOW를 이용한 터널의 지하수 유동해석)

  • Hue, Chang-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.1
    • /
    • pp.129-142
    • /
    • 2003
  • In this study, the conduct of underground water flow system with 3 dimensions is interpreted in order to examine closely the actual condition regarding the flow of the underground water which is forecast from the tunnel segment and the interpretation result which selects the design and the construction technique of the tunnel segment was applied. Also, an obstacle to construct that relates with the underground water flow in construction duration in advance will be able to apply with information that is necessary in order to establish the countermeasure. The objective tunnel is the BEOPGI tunnel segment that is 2 parallel tunnels that are a one-way 2 lane and the parameters of the MODFLOW model executing the boring investigation and the permeability examination were presumed. The underground water flow of the excavation tunnel inside was interpreted by the MODFLOW model using the parameters which is presumed and two values which compared with calculated value and observed value are the same almost. Also, when the underground water discharge quantify that followed in tunnel excavation tries to compare, the underground water total discharge quantity from tunnel point of start until destination was presumed as 0.0269㎥/day/$m^2$.

Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Trace Gas Method under the Presence of Some Cross-draft (방해기류 존재시 추적자 가스법을 이용한 푸쉬풀 후드 효율 평가)

  • Kim, Tae-Hyeung;Ha, Hyun-Chul;Kang, Ho-Gyung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.290-301
    • /
    • 2006
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank. Efficiency of push pull hood system is affected by various parameters, such as, cross draft, vessel shapes, tank surface area, liquid temperature. A previous work assisted by flow visualization technique qualitatively showed that a strong cross draft blown from the pull hood to push slot could destroy a stable wall-jet on the surface of tank, resulting in the abrupt escape of smoke from the surface. In this study, the tracer gas method was applied to determine the effect of cross-draft on the capture efficiency qualitatively. A new concept of capture efficiency was introduced, that is, linear efficiency. This can be determined by measuring the mass of tracer gas in the duct of pull hood while the linear tracer source is in between push slot and pull hood. By traversing the linear tracer source from the push slot to the pull hood, it can be found where the contaminant is escaped from the tank. Total capture efficiency can be determined by averaging the linear efficiencies. Under the condition of cross-draft velocities of 0, 0.4, 0.75, 1.05 and 1.47m/s, total capture efficiencies were measured as 97.6, 95.4, 94.6, 92.7 and 70.5% respectively. The abrupt reduction of efficiency with cross-draft velocity of 1.47m/s was due to the destruction of tank surface wall-jet by the counter-current cross-draft. The same phenomenon was observed in the previous flow visualization study. As an alternative to overcome this abrupt efficiency drop, the 20% increase of hood flow rates was tested, resulting in 20% efficiency increase.

Study of the Flow Characteristics of Supersonic Coaxial Jets (초음속 동축제트의 유동특성에 관한 연구)

  • Lee, Gwon-Hui;Gu, Byeong-Su;Kim, Hui-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1702-1710
    • /
    • 2001
  • Supersonic coaxial jets are investigated numerically by using the axisymmetric, Wavier-Stokes equations which are solved using a fully implicit finite volume method. Three different kinds of coaxial nozzles are employed to understand the flow physics involved in the supersonic coaxial jets. Two convergent-divergent supersonic nozzles are designed to have the same Mach number 2.0, and used to compare the coaxial jet flows with those discharging from one constant-area nozzle. The impingement angle of the annular jets are varied. The primary pressure ratio is changed in the range from 2.0 to 10.0 and the assistant jet ratio from 1.0 to 3.0. The results obtained show that the fluctuations of the total pressure and Mach number along the jet axis are much higher in the constant-area nozzle than those in the convergent-divergent nozzles, and the constant-area nozzle lead to higher total pressure losses, compared with the convergent-divergent nozzles. The assistant jets from the annular nozzle affect the coaxial jet flows within the distance less than about ten times the nozzle throat diameter, but beyond it the coaxial jet is conical with self-similar velocity profiles. Increasing both the primary jet pressure ratio and the assistant jet pressure ratio produces a longer coaxial jet core.

Treatment of Polyester Weight Loss Wastewater by Aerated Submerged Biofilm Process (호기성 침지형 생물막법을 이용한 Polyester 감량폐수의 처리)

  • 박종웅;김대희
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.85-90
    • /
    • 1997
  • The objective of this study was to investigate biodegradation of TPA(terephthalic acid) and EG (ethylene glycol), treatment efficiency of polyester weight loss wastewater and microbial characteristics by aerated submerged biolfilm(ASB) p.rocess. In a batch reactor, pH increased from 7.0 to 8. 5 in the biodegradation of TPA. Whereas, in case of EG, decreased from 7.0 to 5.2. COD concentration rapidly decreased within 24hr in the biodegradation of TPA and EG. COD removal velocity constant(k) were 0.065-0.088 hr$^{-1}$. The biodegradation velocity of TPA was 1.4 times faster than that of EG. The ratio of suspended biomass to the total biomass in the reactor was 18.3-33.3%, increased as a high ratio of EG content. Biofilm thickness, biofilm dry density and attached biomass were 346-432 $\mu$m, 41.8-61.9 mg/cm$^3$, 1.45-2.67 mg/cm$^2$, respectively. There values increased as a high ratio of TPA content. In the hydraulic retention time of 36 hr, organic loading rate of 4 kgCOD/m$^3\cdot$ day and packing ratio of 70%, the effluent concentrations of TCOD, SCOD in a continuous flow reator were 1,388 mg/l, 147 mg/l and removal efficiencies were 77%, 97.6%, respectively.

  • PDF

Self-Excited Noise Generation from Laminar Methane/Air Premixed Flames in Thin Annular Jets

  • Kim K. N.;Joung J. H.;Jin S. H.;Chung S. H.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.147-155
    • /
    • 2004
  • Self-excited noise generation from laminar flames in thin annular jets of methane/air premixture has been investigated experimentally. Various flames were observed in this flow configuration, including conical shape flames, ring shape flames, steady crown shape flames, and oscillating crown shape flames. Self-excited noise with the total sound pressure level of about 70dB was generated from the oscillating crown shape flames for the equivalence ratio larger than 0.95. Sound pressure and $CH^*$ chemiluminescence were measured by using a microphone and a photomultiplier tube. The frequency of generated noise was measured as functions of equivalence ratio and premixture velocity. A frequency doubling phenomena have also been observed. The flame shape during flame oscillation was reconfirmed by a synchronized PIV experiment. The velocity and pressure field were obtained from PIV. The minimum pressure was formed near the edge of flame representing circulation. By comparing the results of sound pressure, flame luminosity and PIV, the noise source can be attributed to the flame front fluctuation near the edge of the oscillating crown-shape flames.

  • PDF

Derivation of Sediment Concentration for the Computation of Total Sediment Discharge (總流砂量의 算定을 위한 流砂濃度式의 導出)

  • Lee, Jong-Seok;Kim, Jin-Gyu;Cha, Yeong-Gi
    • Water for future
    • /
    • v.29 no.1
    • /
    • pp.181-190
    • /
    • 1996
  • Quantitative computation of sediment discharge in alluvial channels is conducted by the determined method based on the incipient motion or the sediment transport concept. The derived formulation of sediment concentration in this study was developed in order to compute the total sediment discharge by a regression analysis method, one of the determined methods by the sediment transport concept. The used data set in derived formulation consists of the total 360 data including 135 and 225 measured data in natural channels and experimental channels, respectively. Also, the formulation by the multiple regression analysis was composed of independent bariables of flow depth, mean velocity, channel slope, Froude number and median diameter in bed materials.

  • PDF

Fouling Behavior of Bentonite Colloidal Suspensions in Microfiltration (벤토나이트 현탁액에 의한 정밀여과 막의 오염특성)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Fouling behavior of polyethylene capillary membranes was examined by measuring the flux of bentonite colloidal suspensions through the cross flow micro filtration. The membrane fouling was due to the three mechanisms: the cake formation on the membrane surface, the standard pore blocking and the complete pore blocking by particles. These mechanisms were simultaneously responsible for the membrane fouling, being significantly governed by the cake filtration. In the total fouling at $1.0kg/cm^2$ TMP condition, the complete blocking was 3.36%, the standard blocking 3.18% and the cake filtration 96.05%. For 1000 ppm feed solution, the complete blocking was 1.71% compared with the standard blocking of 1.90% and the cake filtration of 96.39%. And 96.14% of the total fouling was generated at the initial period of filtration. The cake filtration effect was larger on $0.34{\mu}m$ pore membrane than on $0.24{\mu}m$ pore membrane. With the increase in cross flow velocity, the component fouling decreased by 10.20%, and the ratio of pore blocking to total fouling increased.

An Experimental Study on the Production Rate and Contaminant Removal of Filtrate in Multi-purpose Filtration Pond (다목적 여과저류지에서 여과수의 산출율과 수질개선도에 관한 실험연구)

  • Jeong, Jae-Min;Choi, Hong-Gyu;Jung, Kwan-Sue;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.518-524
    • /
    • 2013
  • A pilot-scale test-bed was operated employing three soils with different grain sizes dredged from the Nakdong River to obtain the design and operation parameters of the multi-purpose filtration pond, such as the filtrate productivity of the filter sand, the appropriate removal period of the surface clogging and the contaminant removal efficiency. The cross-flow velocities were applied stepwise ranging from 0 to 40 cm/sec in order to simulate the various velocities in the artificial stream of the pond. Results showed that a filtrate production rate of 5~3 $m^3/m^2-day$ was maintained by removing the surface clogging every 7 to 13 days and that the filtrate quality was not affected by the factors of the filtrate production rate, the grain size of the filter sand and the cross-flow velocity. Results also showed that most of the removal occurred within 50 cm of the top soil and that the removal efficiencies with the filtration distance of 2.4 m were 80~95% for turbidity, 20~30% for COD, 75~90% for BOD, 5~20% for total nitrogen and 20~60% for total phosphorus, which suggested that particulate matters had a high removal efficiency.

Feasibility study on the application of membrane distillation process to treat high strength wastewater (막 증발법(Membrane Distillation)을 이용한 고농도 하·폐수처리 가능성 연구)

  • Kim, Se-Woon;Lee, Dong-Woo;Min, Kyung-Jin;Cho, Jinwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.261-269
    • /
    • 2015
  • In this study, we applied a membrane distillation process to investigate a feasibility of treating a wastewater with high concentration of organic matters including nitrogen and phosphorus. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$ and porosity of 75%. The installation was direct contact type where the temperature difference between a feed and permeate side was controlled to have a range from 20 to $60^{\circ}C$. We observed a flux variation and a concentration changes of COD, $PO{_4}^{3-}$-P, $NH_4{^+}$-N and conductivity of feed side as well as permeate side with various temperature differences (20 to $60^{\circ}C$), cross flow velocities (0.09 to 0.27 m/s) through the module, and pH (6.6 to 12.0) of the feed that has the initial concentration of COD about 1,000 mg/L, total nitrogen 390 mg/L, total phosphorus 10 mg/L, conductivity of $7,000{\mu}s/cm$. The results showed that the average flux was ranged from 4 to $40L/m^2/hr$ which was almost similar with the flux of NaCl and deionized water used as a feed solution. The lowest flux was obtained at the operating condition with the temperature difference of $20^{\circ}C$ and cross flow velocity of 0.09 m/s while the highest one was measured with $60^{\circ}C$ and 0.27 m/s. Above 99% of COD and $PO{_4}^{3-}$-P in the feed could be rejected regardless of an operating condition. However, the removal rate of ammonium nitrogen was varied from 64 to 99% depending on the pH of feed solution.

Effects of Humidity and Velocity on Frost Distribution Characteristics of Humid Air Flow on Cold Surfaces (차가운 표면위에서의 습공기 유동의 습도 및 속도가 착상분포 특성에 미치는 영향)

  • Kwon Jeong-Tae;Rew Keun-Ho;Lim Hyo-Jae;Han Ji-Won;Kwon Young Chul
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.213-218
    • /
    • 2005
  • In order to understand the heat and mass transfer characteristics of humid airflow in frosting conditions, a flat plate of aluminum with cooling modules located in the central part of the plate was used. A microscope system (resolution of 0.05 mm) was used for the measurement of local thickness of frost at seven points along the plate in the flow direction. For the total mass of frost at each test operation, an electronic balance (resolution of 1 mg) was used. The local frost thickness distributions far various test conditions were presented along with the frost mass data measured at the given operating times. The effect of humidity and velocity of humid air on frosting were analyzed.