• Title/Summary/Keyword: Total dental rehabilitation

Search Result 117, Processing Time 0.02 seconds

Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin (수리된 비스 아크릴 복합 레진의 전단결합강도에 대한 지연시간, 표면처리, 수리 재료의 영향)

  • Park, Ji-su;Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bis-acryl composite resin through comparison of shear bond strength and to evaluate the utility of bis-acryl composite resin repair using polymethyl methacrylate resin. Materials and Methods: A total of 90 bis-acryl composite resin specimens were fabricated and classified into 9 test groups, each of 10 pieces according to delayed time, surface treatment and repair material. The shear bond strength of each specimen was measured using a universal testing machine immediately after fabrication and analyzed using a statistical analysis program (IBM SPSS statistics 20). After the shear bond strength measurement, the fracture surface of the specimen was observed. Results: The highest shear bond strength ($17.54{\pm}3.14MPa$) was observed in the experimental group bonded immediately with a light-curing flowable composite resin using a bonding agent. Conclusion: When repairing bis-acryl composite resin, it is necessary to consider whether to remake according to the delayed time. For effective repair, it is desirable to consider appropriate materials and surface treatment methods according to the site or purpose of use.

Analysis on mandibular movement using the JT-3D system (JT-3D system을 이용한 하악의 운동 분석)

  • Song, Joo-Hun;Kim, Ryeo-Woon;Byun, Jae-Joon;Kim, Hee-Jung;Heo, Yu-ri;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.80-87
    • /
    • 2020
  • Purpose: This study aims to measure the mandibular movement using JT-3D system and provide a range of mandibular movement that can serve as a good reference for diagnosing the temporomandibular disorder. Materials and Methods: This study was conducted in 60 young male and female adults. The maximum opening and closing movement was recorded using JT-3D system, and by regarding 5 times of repetitive movement as 1 cycle of movement, total 3 cycles of movement were recorded. During the maximum opening, vertical position of lower jaw, antero-posterior position, lateral deflection position, and maximum opening distance were recorded. To evaluate the reproducibility of JT-3D system, statistical analysis were conducted (α = 0.05). Results: During the maximum opening, the average value appeared at 31.56 mm vertically and 24.42 mm rearwardly, lateral deflection position 0.72 mm, and maximum opening distance 40.32 mm. There was no statistical significance in all measured values for three cycles of movement recorded with JT-3D system (P > 0.05). Conclusion: During the maximum opening, the average value appeared at 0.72 mm in lateral deflection position and the maximum opening distance at 40.32 mm, and the analysis on the maximum opening of lower jaw using JT-3D system showed sufficiently reproducible results.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

Efficacy of Aloclair$^{TM}$ for Treatment of Intraoral Ulcer Caused by Orthodontic Appliance (교정장치에 의해 유발된 구내궤양 치료에 대한 Polyvinylpyrrolidone-sodium hyaluronate (Aloclair$^{TM}$)의 임상적 효과)

  • Lee, Ju-Hee;Lee, Sang-Min;Park, In-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.109-118
    • /
    • 2012
  • This experimental study was undertaken to evaluate the efficacy of polyvinylpyrrolidone-sodium hyaluronate(Aloclair$^{TM}$) in decreasing pain in orthodontic procedures. A total of 60 patients who were use Aloclair$^{TM}$ ordered to were included. These patients were categorized by 3 cases; 1. Patients who were bonded with their first brackets. 2. Patients who were in pain with additional appliance such as anchorage devices. 3. Patients who got ulcer caused by appliances. We collected information about pain and assessed it using visual analogue scale. According to questionnaire, it took 3.5 min. for pain to subside and pair relief durated for 2.7 hours. Most patients in the study reported rapid pain relief and found Aloclair$^{TM}$ easy and pleasant to use than wax. Accordingly Aloclair$^{TM}$ provided raid relief of resting and provoked ulcer pain.

Patient-reported outcome measures on intake of nutrition drink for nutritional supplements after periodontal surgery (외과적 치주 치료 후 식이보충을 위한 영양음료 섭취에 관한 patient-reported outcome measures (PROMs) 조사)

  • Kim, Hyeong-Seok;Cho, In-Woo;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.176-183
    • /
    • 2016
  • Purpose: Patients usually suffer from pain and discomfort after oral surgery and their consumption of food is severely affected. Accordingly, the patients' quality of life reduce significantly. The aim of this study was to analyze patient satisfaction on the nutritional supplement drinks following periodontal surgery. Materials and Methods: Total 90 patients who underwent periodontal surgery were recruited and commercially available nutritional drinks were provided. Group I received two bottles per each meal for 2 days, Group II had one bottle per each meal for 3 days, and Group III had no drinks. The survey for the patient-reported outcome measures (PROMs) were given at the next visit for the removal of sutures. Results: The result of PROMs showed the nutrition drink was easy to intake, appeared to help the healing and can be a satisfying supplement for the meals. Conclusion: Nutritional drinks appeared to help the healing after periodontal surgeries and supported the food intake. Also, it was helpful for the patients in nutritional supply and psychological stability.

Evaluation of Tightness of Proximal tooth Contact on Implant Prostheses (임프란트 보철수복물에서의 인접치간 접촉강도의 평가)

  • Kim, Sang-Pil;Jung, J-Hyun;Kang, Dong-Wan;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.371-379
    • /
    • 2008
  • The aim of this study was to evaluate the tightness of proximal tooth contact(TPTC) using a novel device at rest state on implant prostheses. Ten healthy young adults with class I normal occlusion consented to participate in the study and twenty patients were restored with a total 20 single-implant crowns in the left maxillary and mandibular second molars for 10 single-implant crowns, respectively. Test area were divided by 4 groups. UM describes the contact between the upper natural left first molar and natural second molar; LM the contact between the lower natural left first molar and natural second molar; IUM the contact between the upper natural left first molar and implant second molar and ILM the contact between the lower natural left first molar and implant second molar. The TPTC was measured at rest state in each area. The mean TPTC of the UM, LM, IUM and ILM was 1.48(${\pm}0.44$) N, 1.78(${\pm}0.40$) N, 1.14(${\pm}0.37$) N and 1.30(${\pm}0.32$) N respectively. These results indicate that the TPTC was less between natural tooth and implant prosthesis than between natural teeth.

Characterization of the Stresses in the Luting Cement Layer Affected by Location of the Occlusal Points and Loading Direction on a Full Veneer Crown (유한요소법을 이용한 전부주조관의 교합점 위치와 하중방향이 시멘트층 내 응력에 미치는 영향)

  • Lee, Jung-Hoon;Lee, Kyu-Bok;Lee, Cheong-Hee;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • The objective of this study was to test effects of (1) where the occlusal contact points locate on a full veneer crown, and (2) which direction the contact forces are directed to, on the stresses within the luting cement layer that might suffer microfracture. A total of 27 finite element models were created for a mandibular first molar, combining 9 different locations of the occlusal contact points and 3 different loading directions. Type 3 gold alloy was used for crown material with a chamfer margin, and the luting cement material was glass ionomer cements in uniform thickness of $75{\mu}m$. Modeled crowns were loaded at 100 N. Different patterns in the cement stress were observed in the vicinity of the buccal and lingual margins. Whereas, the peak stress in buccal margin occurred approximately 0.5 mm away from the external surface, the highest stress in lingual margin was observed at approximately 1 mm. Significantly different distribution of stresses was recorded as a function either of the location of the occlusal contact points or of the loading direction. Higher stresses were produced by more obliquely acting load, and when the loaded point was in the vicinity of the cusp tip.

Characteristics of Fluoride Releasing of Anodized Titanium Implant (양극산화 아크방전 처리한 티타늄 임플란트의 불소방출 특성)

  • Kim, Ha-young;Song, Kwang-yeob;Bae, Tae-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.361-369
    • /
    • 2008
  • The purpose of this study is to make porous oxide film on the surfaces of pure Ti through anodic spark discharge in electrolytic solution containing calcium and phosphate ions, to improve osseointergration by treating fluoride agent. In addition, it is to evaluate the fluoride modified effect on the surface. Commercial pure Ti plate with $20{\times}10{\times}2mm$ and Ti wire with a diameter of 1.5mm and a total length of 15mm were used. After making titanium oxide films converted by anodic spark discharge, anodizing was performed. Fluoride was spreaded to titanium laboratory plate and maintained for 30 minutes after anodizing breakdown. Fluoride ion discharge amount was measured per 24 hours after dipping titanium plate into saline (10ml) and sustaining 90rpm in a pyrostat. Some plates and wires were dipped in Hanks solutions for a month to examine biocompatibility using SEM and XRD. $TiO_2$ film formed by anodic discharge technique showed great roughness and uniform pores which were $1{\sim}3{\mu}m$ in a diameter. Roughness of the films treated with anodic discharge after blasting were higher than the turned ones(P<0.05). Rapid surface activity was observed in the samples treated with $TiF_3$ agent, which immersed in Hanks solution for 30 days. Taking the results into consideration, the fluoride modified implant with anodic discharge demonstrates that it makes uniformly porous oxide film on the surface of implant and properly increase roughness for osseointegration. The implants will achieve greater bone integration after short healing time by improving surface activity.

A 3 year prospective study of survival rate of narrow diameter implants (좁은 직경 임플란트 3년간의 생존율에 관한 후향적 연구)

  • Lee, Sung-Jo;Jung, Sae-Young;Shin, Hyun-Seung;Park, Jung-Chul;Song, Young-Gyun;Cho, In-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.32-38
    • /
    • 2018
  • Purpose: The purpose of present study was to retrospectively analyze the survival rate of narrow diameter implant less than 3.6 mm by initial stability and radiographic measurements. Materials and Methods: In total, 24 patients who received 38 narrow diameter implants (${\leq}3.6mm$ in diameter, ${\geq}7mm$ in length) were enrolled in this retrospective study. The cumulative survival rate was calculated and various factors were investigated according to the implant platform diameter, body diameter, length, position, concomitant use of guided bone regeneration in implant placement and final prosthesis type. Initial stability was investigated with implant stability quotient (ISQ) value. The mesial and distal marginal bone level (MBL) change was calculated with radiography. Results: The overall survival rate was 92.11%. Mean ISQ value and MBL change of survival implants was 66.26 and $0.14{\pm}0.31mm$, respectively. None of the implants with platform diameters larger than the body diameter failed. Conclusion: In conclusion, the findings of present study suggest that narrow diameter implant could be predictable treatment in narrow alveolar ridge.

A study of incidence of palatal side abfractions in maxillary posterior teeth (상악 구치에서의 구개측 굴곡파절 발현 비율 연구)

  • Song, Joo-Hun;Heo, Yuri;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.206-213
    • /
    • 2019
  • Purpose: Most of studies dealing with abfractions are limited to the buccal surfaces of the teeth. In this study, we analyzed the cause for abfraction by investigating the incidence of palatal side abfractions in maxillary posterior teeth. Materials and Methods: We investigated a total of 3193 maxillary posterior teeth by an intraoral examination, model observation, and observation of virtual model fabricated using model scanning. We recorded the results and classified them depending on the type of teeth, age, gender, and side of arches. We also performed Chi-square test to evaluate the statistical significance among the groups (α = 0.05). Results: The incidence of palatal side abfraction of the maxillary molars (10.8%) was higher than the premolars (6.8%), and among them, the incidence of the 1st molars (39.1%) were the highest. The incidence of palatal side abfraction increased with age and was statistically significant (P < 0.05). There was no statistical significance in the difference by gender (P > 0.05); in the case of arches, left arch showed higher incidence and it was statistically significant (P < 0.05). Conclusion: Palatal side abfraction in maxillary posterior teeth was frequently observed in the maxillary 1st molars, and the incidence increased with age. This result suggests that the main reason for abfraction is due to occlusal force.