• 제목/요약/키워드: Torsional irregularity

검색결과 34건 처리시간 0.023초

고층 RC 벽식 비정정 구조물의 지진거동에 관한 실험적 연구 (Experimental Study on the Seismic Response of High-Rise RC Bearing-Wall Structures with Irregularity)

  • 이한선;고동우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.321-328
    • /
    • 2003
  • The objective of this study is to investigate the seismic response of high-rise RC bearing-wall structures with irregularity. For this purpose, three 1:12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames have three different layouts of the plan : The first one is a moment-resisting frame system, the second has a infilled shear wall with symmetric plan and the third has a infilled shear wall with eccentricity, Then, these models were subjected to a series of earthquake excitations. The test results show the followings: 1) the existence of shear wall reduced greatly shear deformation at the piloti frame, but has almost the negligible effect on the reduction of the overturning-moment angle, 2) the frame with shear wall resists most of overturning moment in severe earthquake, 3) the torsional behavior is almost independent of the translational, 4) the absorbed energy due to the overturning deformation has the largest portion in the total absorbed energy.

  • PDF

비틀림 비정형을 갖는 철골특수모멘트골조의 내진성능평가 - II 내진설계 방법개선 (Seismic Performance Evaluation of Special Moment Steel Frames with Torsional Irregularities - II Improving Seismic Design Method)

  • 한상환;김태오
    • 한국강구조학회 논문집
    • /
    • 제29권5호
    • /
    • pp.369-376
    • /
    • 2017
  • 본 논문은 ASCE 7-10를 적용한 비틀림 비정형 철골 모멘트 골조의 설계 및 평가를 수행한 동반연구(I 내진설계)의 후속 연구이다. 본 연구에서는 철골 모멘트 골조의 비틀림 비정형 발생 여부와 ASCE 7-10 설계 요구조건의 적용 여부에 따라 내진성능평가를 수행하였다. 그 결과, ASCE 7-10의 비정형 내진설계 요구조건을 적용한 철골 모멘트 골조의 경우 붕괴확률이 매우 낮고 상당히 보수적인 설계 결과를 나타냈으며, 본 연구에서는 비틀림 비정형 구조물의 합리적인 설계를 위해 개선된 설계 방법을 제시하였다. 제안된 방법으로 설계된 비틀림 비정형 철골 모멘트 골조의 붕괴확률은 기존의 방법으로 설계된 구조물의 붕괴확률을 보다 크지만 ASCE 7-10의 붕괴확률 요구 조건을 만족하였다.

고층 철근콘크리트 건축구조모델의 지진응답에 대한 해석적 모사 (Analytical Simulation of the Seismic Response of a High-Rise RC Building Model)

  • 이한선;이정재;정동욱
    • 한국지진공학회논문집
    • /
    • 제12권5호
    • /
    • pp.1-10
    • /
    • 2008
  • Taft N21E 지진파를 사용하여 1:12 축소된 모델로 여러번의 진동대 실험을 저층부 2개층에 비틀림과 연층을 가지는 17층 고층 철근콘크리트 건물에 대해 지진 거동을 조사하기 위해 수행했었다. 이 거동의 주요 특징은 (1) 연약 골조가 거대한 비탄성 변형을 받은 후 변형이나 비틀림에서 비틀림 모드까지 현저한 진동의 갑작스런 변화, (2) 이러한 모드 변화에 따른 비틀림 강성의 갑작스런 증가, (3) 비틀림 모드에서 월의 요곡(warping) 거동, 그리고 (4) 진동대 거동의 반대 방향에만 생기는 전도모멘트 양상을 보여주었다. 본 연구에서는 이러한 성과를 Perform3D라는 비선형 해석 프로그램을 사용하여 위 특성을 모사하기 위해 노력하였다. 이 소프트웨어에서 가용한 비선형 모델과 함께 그의 장점과 단점을 해석 및 실험 결과의 비교를 통해 제시하였다.

Methods of analysis for buildings with uni-axial and bi-axial asymmetry in regions of lower seismicity

  • Lumantarna, Elisa;Lam, Nelson;Wilson, John
    • Earthquakes and Structures
    • /
    • 제15권1호
    • /
    • pp.81-95
    • /
    • 2018
  • Most buildings feature core walls (and shear walls) that are placed eccentrically within the building to fulfil architectural requirements. Contemporary earthquake design standards require three dimensional (3D) dynamic analysis to be undertaken to analyse the imposed seismic actions on this type of buildings. A static method of analysis is always appealing to design practitioners because results from the analysis can always be evaluated independently by manual calculation techniques for quality control purposes. However, the equivalent static analysis method (also known as the lateral load method) which involves application of an equivalent static load at a certain distance from the center of mass of the buildings can generate results that contradict with results from dynamic analysis. In this paper the Generalised Force Method of analysis has been introduced for multi-storey buildings. Algebraic expressions have been derived to provide estimates for the edge displacement ratio taking into account the effects of dynamic torsional actions. The Generalised Force Method which is based on static principles has been shown to be able to make accurate estimates of torsional actions in seismic conditions. The method is illustrated by examples of two multi-storey buildings. Importantly, the black box syndrome of a 3D dynamic analysis of the building can be circumvented.

Seismic performance sensitivity to concrete strength variability: a case-study

  • Stefano, M. De;Tanganelli, M.;Viti, S.
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.321-337
    • /
    • 2015
  • Existing building structures can easily present material mechanical properties which can largely vary even within a single structure. The current European Technical Code, Eurocode 8, does not provide specific instructions to account for high variability in mechanical properties. As a consequence of the high strength variability, at the occurrence of seismic events, the structure may evidence unexpected phenomena, like torsional effects, with larger experienced deformations and, in turn, with reduced seismic performance. This work is focused on the reduction in seismic performance due to the concrete strength variability. The analysis has been performed on a case-study, i.e., a 3D RC framed 4 storey building. A Normal distribution, compatible to a large available database, has been taken to represent the concrete strength domain. Different plan layouts, representative of realistic strength distributions, have been considered, and a statistical analysis has been performed on the induced reduction in seismic performance. The obtained results have been compared to the standard analysis as provided by Eurocode 8 for existing buildings. The comparison has shown that the Eurocode 8 provisions are not conservative for existing buildings having a large variability in concrete strength.

비정형 셀프센터링 가새골조의 비탄성 지진응답 (Inelastic Seismic Response of Asymmetric-Plan Self-Centering Energy Dissipative Braced Frames)

  • 김진구;;최현훈
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.35-44
    • /
    • 2008
  • 최근 새로운 지진하중 저항시스템으로 셀프센터링(SCED) 가새 시스템이 개발되었다. 진보된 가새 시스템인 비좌굴 가새(BRB) 시스템과는 달리 큰 지진이 발생한 후 구조물의 잔류 변형을 줄이거나 없앨 수 있는 셀프센터링 능력은 SCED 가새 시스템의 장점이다. 본 논문에서는 SCED 가새와 BRB 가새 시스템의 거동에 비틀림의 영향을 조사하기 위하여 세 가지 다른 편심을 가진 3차원 구조물의 응답을 비선형 동적해석을 수행하여 비교하였다. 해석결과에 따르면 층간변위의 높이방향의 변화는 비정형성에 관계없이 SCED 가새골조의 응답이 BRB 가새골조보다 일정하였으며, 잔류 층간변위와 잔류 회전 응답은 비정형성이 증가함에 따라 감소하였다. 중층 구조물에서 SCED 가새골조의 변형집중계수(DCF)는 BRB 가새골조보다 작은 것으로 나타났다. 이것은 SCED 가새골조가 건물 높이에 따라 보다 일정하게 변형함을 의미한다. DCF의 크기에 대한 비틀림 비정형의 효과는 작았다.

비틀림 비정형성을 가진 RC 건물의 설계편심 (Design Eccentricity of RC Building Structures with Torsional Irregularity)

  • 이한선;고동우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.140-143
    • /
    • 2003
  • Recently, many high-rise reinforced concrete (RC) bearing wall structures of multiple occupancy have been constructed, which have the irregularities of weak (or soft) story and torsion at the lower stories simultaneously. The study compared the eccentricity of such a building predicted by design codes, EC 8, IBC 2000 and UBC 97, and by the test results through a series of shaking table tests of 1:12 model. Based on the comparison of the predicted eccentricity and the test result, the conclusions are drawn as follow: Accidental torsion due to the uncertainty on the properties of structure can be reasonably predicted by using the dynamic analysis with the center of mass being shifted by 5 percent of the dimension of the building perpendicular to the direction of the excitations than by using equivalent lateral force procedure

  • PDF

Seismic analysis of high-rise steel frame building considering irregularities in plan and elevation

  • Mohammadzadeh, Behzad;Kang, Junsuk
    • Steel and Composite Structures
    • /
    • 제39권1호
    • /
    • pp.65-80
    • /
    • 2021
  • Irregularities of a building in plan and elevation, which results in the change in stiffness on different floors highly affect the seismic performance and resistance of a structure. This study motivated to investigate the seismic responses of high-rise steel-frame buildings of twelve stories with various stiffness irregularities. The building has five spans of 3200 mm distance in both X- and Z-directions in the plan. The design package SAP2000 was adopted for the design of beams and columns and resulted in the profile IPE500 for the beams of all floors and box sections for columns. The column cross-section dimensions vary concerning the number of the story; one to three: 0.50×0.50×0.05m, four to seven: 0.45×0.45×0.05 m, and eight to twelve: 0.40×0.40×0.05 m. Real recorded ground accelerations obtained from the Vrancea earthquake in Romania together with dead and live loads corresponding to each story were considered for the applied load. The model was validated by comparing the results of the current method and literature considering a three-bay steel moment-resisting frame of eight-story height subject to seismic load. To investigate the seismic performance of the buildings, the time-history analysis was performed using ABAQUS. Deformed shapes corresponding to negative and positive peaks were provided followed by the story drifts and fragility curves which were used to examine the probability of collapse of the building. From the results, it was concluded that regular buildings provided a seismic performance much better than irregular buildings. Furthermore, it was observed that building with torsional irregularity was more vulnerable to seismic failure.

Collapse response assessment of low-rise buildings with irregularities in plan

  • Manie, Salar;Moghadam, Abdoreza S.;Ghafory-Ashtiany, Mohsen
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.49-71
    • /
    • 2015
  • The present paper aims at evaluating damage and collapse behavior of low-rise buildings with unidirectional mass irregularities in plan (torsional buildings). In previous earthquake events, such buildings have been exposed to extensive damages and even total collapse in some cases. To investigate the performance and collapse behavior of such buildings from probabilistic points of view, three-dimensional three and six-story reinforced concrete models with unidirectional mass eccentricities ranging from 0% to 30% and designed with modern seismic design code provisions specific to intermediate ductility class were subjected to nonlinear static as well as extensive nonlinear incremental dynamic analysis (IDA) under a set of far-field real ground motions containing 21 two-component records. Performance of each model was then examined by means of calculating conventional seismic design parameters including the response reduction (R), structural overstrength (${\Omega}$) and structural ductility (${\mu}$) factors, calculation of probability distribution of maximum inter-story drift responses in two orthogonal directions and calculation collapse margin ratio (CMR) as an indicator of performance. Results demonstrate that substantial differences exist between the behavior of regular and irregular buildings in terms of lateral load capacity and collapse margin ratio. Also, results indicate that current seismic design parameters could be non-conservative for buildings with high levels of plan eccentricity and such structures do not meet the target "life safety" performance level based on safety margin against collapse. The adverse effects of plan irregularity on collapse safety of structures are more pronounced as the number of stories increases.

Mitigating the effect of urban layout on torsion of buildings caused by infill walls

  • Noorifard, Azadeh;Tabeshpour, Mohammad Reza;Saradj, Fatemeh Mehdizadeh
    • Earthquakes and Structures
    • /
    • 제23권2호
    • /
    • pp.151-168
    • /
    • 2022
  • Torsion is one of the most important causes of building collapse during earthquakes. Sometimes, despite the symmetric form of the building, infill walls disturb the symmetry of the lateral resisting system. The purpose of this research is to investigate the effect of urban layout on developing torsion caused by infill walls. For this purpose, a typological study was conducted based on the conditions of perimeter walls on 364 buildings and then 9 cases were selected. The dimensions of the selected buildings are constant and the conditions of the perimeter walls including facades with openings and cantilevered facades are variable. The selected buildings with 60 different layouts of infill walls were analyzed and the behavior of each one was evaluated based on the torsional irregularity criteria of seismic codes. The results of the analyses showed that if the perimeter walls of a building are symmetric, asymmetric interior walls will not be important in developing torsion and effective parameters in symmetry of the perimeter infill walls are the number of walls, area of openings, aspect ratio, and construction details. Finally, architectural solutions to mitigate the torsional effects of infill walls were proposed for buildings with solid infill walls on some sides, for buildings where the perimeter walls of one side are on the cantilevered part, and for buildings where the perimeter walls of two adjacent sides are on the cantilevered part. In three-sided buildings, where two adjacent façades are cantilevered, it is often impossible to use the potential of the infill walls.