• Title/Summary/Keyword: Top Side

Search Result 706, Processing Time 0.022 seconds

Behavior of Floating Top-Base Foundation on Soft Soils by Laboratory Model Tests (실내모형실험을 통한 연약지반에서 부양형 팽이기초의 거동)

  • Chung, Jin-Hyuck;Chung, Hye-Kwun;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.5-15
    • /
    • 2011
  • This research performed the laboratory model tests for Top-Base Foundation developed in Japan and Floating Top-Base Foundation developed in Korea on the typical clayey soft soils, namely, clay, clayey silt and clayey sand. The performances of the two types of top-base foundation were compared with each other and evaluated by measuring load-settlement, heaving of foundation side, ground stress distribution in this model tests. The change of settlement caused by the increase of top base width was also analyzed. As a result of the model tests, Floating Top-Base Foundation showed better performance in bearing capacity improvement, settlement decrease, stress dispersion effect and lateral confinement force. And settlement caused by the increase of top base width converged to a regular value from $5{\times}5$ layout of the width.

A Study On XML Based Open Service Platform For Demand-Side Resource Management (XML 기반의 수요자원 관리 개방형 서비스 플랫폼에 관한 연구)

  • Yoon, Jae-Weon;Um, Dae-Jin;Choi, Jung-In;Lee, Ingyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.43-48
    • /
    • 2014
  • With the energy paradigm shift from supply side management to demand side management, many researches have been done on demand side resource management and demand response. At the same time, Obix, BacNet-WS and OPC-UA are popularly used in buildings and industry energy management system. However, it is not easy to interchange the data and information among the systems cause a variety of protocols are used in buildings and factories. Therefore, in this paper, we are proposing an open business platform not only to integrate and manage the demand resources using various protocols and standards, but also to allow to plug-ins a new business service on top of the platform.

Identification of Rice Species by Three Side (Top, Side and Front) Images of Brown Rice (현미 세 면(윗면, 측면, 앞면)의 화상을 이용한 품종 판별)

  • Kim, Sang-Sook;Lee, Sang-Hyo;Rhyu, Mee-Ra;Kim, Young-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.473-479
    • /
    • 1998
  • Identification of rice species was attempted by three side (top, side and front) images of brown rice. Nine parameters of each image were area, aspect ratio, maximum diameter, minimum diameter, perimeter, roundness and red (R), green (G) and blue (B) pixel values of an image. Forty rice samples consisted of 19 species used for the study and total 27 image characteristics for a kernel were measured. For calibration and confirmation, 105 and 20 brown rice kernels per each sample were used respectively. For best identification of rice species, 24 image characteristics were selected for discriminant analysis. Average percentages for correct identification of rice species were 84.75% and 84.93% for calibration and confirmation data set, respectively. The highest and lowest percentage for correct identification were 99.05% for Nongan and 50.63% for Hwaseung respectively in calibration data. The confirmation data showed that the correct identification of Nongan or Paalgong was 100%, while that of Hwaseung was 47.62%. The result of the study showed that three side (top, side and front) image of brown rice was not suitable for identification of rice species suggesting that additional techniques are required for better discrimination of rice species.

  • PDF

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing Cs-137 Source by a Computer (컴퓨터 의한 Fletcher-Suit Colpostat 주변의 Cs-137의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.305-311
    • /
    • 1989
  • Fletcher-Suit colpostat has an internal structure to reduce dose to bladder and rectum. Some programs were developed to calculate dose at any point in water in three dimension around the colpostat containing Cs-137 tube, to find the shielding effect to dose by the internal structure, and to draw isodose curves and iso-shielding effect curves. Computer was an IBM compatible AT with EGA card and language was MS-Basic V6.0, Material, shape and geometry of the strucure, tube and colpostat were considered in algorithm for calculation of dose. Dose rates per unit mg. Ra. eq. in water calculated by a program were stored in auxiliary memory devices and retrieved in another programs. Isodose curves on medial side shrinked. Dose distribution was not symmetric about a transverse axis bisecting the colpostat. Reduction of dose was more excessive on top side than on bottom. Iso-shielding effect curve showed that the shielding effect was higher on top side than on bottom, and that there was shielding effect over almost all area of medial side. Such results were related to both shifted position of tube in the colpostat and asymmetric distribution of active source in the tube. Maximum of shielding effect was $49\%$ on top side and $44\%$ on bottom side. The direction of iso-shielding effect curve was generally radial from the center of active source. In treatment planning using Fletcher-Suit colpostat, the internal structure should be considered to find precise doses to bladder and rectum, etc.

  • PDF

A Side-and Rear-View Image Registration System for Eliminating Blind Spots (차량의 사각 지대 제거를 위한 측/후방 카메라 영상 정합 시스템)

  • Park, Min-Woo;Jang, Kyung-Ho;Jung, Soon Ki;Yoon, Pal-Joo
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.8
    • /
    • pp.653-663
    • /
    • 2009
  • In this paper, we propose a blind spots elimination system using three cameras. A wide-angle camera is attached on trunk for eliminating blind spots of a rear-view mirror and two cameras are attached on each side-view mirror for eliminating blind spots of vehicle's sides. In order to eliminate blind spots efficiently, we suggest a method to build a panoramic mosaic view with two side images and one wide-angle rear image. First, we obtain an undistorted image from a wide-angle camera of rear-view and calculate the focus-of-contraction (FOC) in undistorted images of rear-view while the car is moving straight forward. Second, we compute a homography among side-view images and an undistorted image of rear-view in flat road scenes. Next, we perform an image registration process after road and background region segmentation. Finally, we generate various views such as a cylinder panorama view, a top view and an information panoramic mosaic view.

Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report (진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고)

  • Hyun, Sang Woo;Lee, sungbok Richard;Lee, Suk Won;Cho, Young Eun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.478-486
    • /
    • 2021
  • This report demonstrates a method of generating a chair-side and computer-aided template for implant surgery based on the Top-Down and restoration-driven concept. Compared to the traditional CAD-CAM process which requires multiple steps to be taken between dental clinic and laboratory, this alternative procedure, VARO guide system (VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea) enables accurate and patient-friendly implant surgery as well as immediate provisional restoration in a single visit. First, bite-registration at centric jaw relation and CBCT were taken using the Pre-Guide. The CBCT data was then reorganized directly through the chair-side CAD, and we could determine the most appropriate 3-dimensional position of implant. The STL file was extracted and put into the chair-side CAM (VARO-mill) to fabricate a VARO. This surgical guide allowed the implants to be accurately positioned into the planned sites within an hour.

Performance Analysis of A Modified Asymmetric Rectangular Fin

  • Kang, Hyung Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.6 no.2
    • /
    • pp.109-120
    • /
    • 2002
  • The dimensionless heat loss from a modified asymmetric rectangular fin is investigated as a function of the fin top and tip Biot numbers using the two-dimensional separation of variables method. A rectangular fin is modified by attaching the wing on the top side of the fin. Fin effectiveness and efficiency with the variation of the location of the wing and the width of the wing are presented. The relationship between top surface Biot number and bottom surface Biot number as well as the relationship between the dimensionless wing height and the location of the wing for equal amount of heat loss is also discussed.

  • PDF

다공질 실리콘을 이용한 전계 방출 소자

  • 주병권
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.05a
    • /
    • pp.92-97
    • /
    • 2002
  • We establish a visible light emission from porous polycrystalline silicon nano structure(PPNS). The PPNS layer are formed on heavily doped n-type Si substrate. 2um thickness of undoped polycrystalline silicon deposited using LPCVD (Low Pressure Chemical Vapor Deposition) anodized in a HF: ethanol(=1:1) as functions of anodizing conditions. And then a PPNS layer thermally oxidized for 1 hr at $900 ^{\circ}C$. Subsequently, thin metal Au as a top electrode deposited onto the PPNS surface by E-beam evaporator and, in order to establish ohmic contact, an thermally evaporated Al was deposited on the back side of a Si-substrate. When the top electrode biased at +6V, the electron emission observed in a PPNS which caused by field-induces electron emission through the top metal. Among the PPNSs as functions of anodization conditions, the PPNS anodized at a current density of $10mA/cm^2$ for 20 sec has a lower turn-on voltage and a higher emission current. Furthermore, the behavior of electron emission is uniformly maintained.

  • PDF

Corrosion Assessment of Storage Tank Floor using Magnetic Flux Leakage Technique (누설자속법을 이용한 저장탱크 바닥판재의 부식 평가)

  • Won, Soon-Ho;Cho, Kyung-Shik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.38-45
    • /
    • 2000
  • In this research, MFL technique has been studied for the inspection of storage tank floor. The reference specimens having 20%, 40%, 60% and 80% slot's are fabricated using the carbon steel plates of a 6mm and 10mm thick. Powerful permanent magnets and Hall effect sensors are used to this application. It is shown that our system is able to detect metal loss like a slot. Also, it is possible that slot diameter is measured using transverse type of Hall generator. It is demonstrated that MFL can not differentiate between the response from top side and bottom side slot. Flux leakage response from a bottom side indication is significantly lower in amplitude than that from an equivalent top side slot. It is essential to know this sensor lift-off distance because the MFL signal also changes considerably with the sensor lift-off distance.

  • PDF

Characteristic Changes of Swine Manure by Air Suction Composting System (돈분 퇴비화 시 공기 흡입 시스템에 따른 퇴비화 특성 변화)

  • Lee, Dong-jun;Kim, Jung Kon;Jeong, Kwang-Hwa;Cho, Won-Mo;Ravindran, B.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.63-74
    • /
    • 2016
  • The objective of this study was to investigate the variations of physico-chemical properties during the swine manure composting, sawdust as the bulking agent was composted at different points (Top layer, Side of middle layer, Bottom layer). Air suction system with constant bottom aeration in bench scale reactors (30 L). The highest temperature was reached in the range of $58^{\circ}C$ to $62^{\circ}C$ on $3^{rd}$ day and this thermophilic phase (> $50^{\circ}C$) was continued for 3 days in all the treatment mixtures. However, the temperature was gradually decreased to room temperature at the end of 60 day composting process. Except control, the discharged ammonia ($NH_3$) was a maximum in the treatment order of Top layer>Bottom layer>Side of middle layer as 500 ppm, 162 ppm and 120 ppm, respectively, on the $4^{th}$ day and showing that Top layer point Air suction produce much more ammonia content than the other point. During the composting process, the total Kjeldahl nitrogen (TKN) was gradually increased due to the mass loss in the composting mixtures. At the same time, C/N ratio was decreased to Top layer, 13; Side of middle layer, 12 and Bottom layer, 13 at Air suction points. The significant reduction of C/N ratio in all different air suction system when manure was matured. The $NH_4-N$ to $NO_3-N$ ratio was recorded as 10.52 at the initial stage of the compost mixtures and reduced to 0.97 (Top layer), 0.70 (Side of middle layer), 3.2 (Bottom layer) because of manure decomposition. The overall results revealed that Top layer and Side of middle layer Air suction is a suitable option when compared other point for high quality composts.