• Title/Summary/Keyword: Tooth model

Search Result 567, Processing Time 0.031 seconds

Maxillary molar derotation and distalization by using a nickel-titanium wire fabricated on a setup model

  • Jung, Jong Moon;Wi, Young Joo;Koo, Hyun Mo;Kim, Min Ji;Chun, Youn Sic
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.268-274
    • /
    • 2017
  • The purpose of this article is to introduce a simple appliance that uses a setup model and a nickel-titanium (Ni-Ti) wire for correcting the mesial rotation and drift of the permanent maxillary first molar. The technique involves bonding a Ni-Ti wire to the proper position of the target tooth on a setup model, followed by the fabrication of the transfer cap for indirect bonding and its transfer to the patient's teeth. This appliance causes less discomfort and provides better oral hygiene for the patients than do conventional appliances such as the bracket, pendulum, and distal jet. The treatment time is also shorter with the new appliance than with full-fixed appliances. Moreover, the applicability of the new appliance can be expanded to many cases by using screws or splinting with adjacent teeth to improve anchorage.

Influencing factors of oral health by PRECEDE model (PRECEDE 모형을 이용한 구강건강의 영향요인에 대한 진단적 연구)

  • Cho, Min-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.3
    • /
    • pp.525-534
    • /
    • 2013
  • Objectives : This study aimed to improve school health program by investigation of several variables through educational diagnostic factors which influence the level of subjective oral health perception and DMFT of students on the basis of PRECEDE model. Methods : A total of 286 high school students in Busan completed the self-reported questionnaire from September 3 to 28 in 2012. Results : 1. Social and epidemiologic diagnosis suggested that the level of subjective oral health perception of male students was not better than that of female students and DMFT number of the male was more than that of the female(p<0.001)(p<0.001). 2. Oral health diagnosis indicated that once a day tooth brushing group showed lower level of oral health perception(p<0.001) and high DMFT number(p<0.001). 3. Predisposing factor of educational diagnosis implied that more than 4 times a day snack intake group and sweet diet and soda friendly group showed lower level of oral health perception and high DMFT number(p<0.001). 4. Tooth brushing of the reinforcing factors had the most important effect on the level of oral health perception and the number of dental caries. Daily snack intake was the most important effect on DMFT number. Conclusions : The informed consent from each family was the important factor in implementing PRECEDE model. School health program improved oral health care. Oral health program can correct the risk oral health behavior in children and adolescents.

Three-dimensional comparison of 2 digital models obtained from cone-beam computed tomographic scans of polyvinyl siloxane impressions and plaster models

  • Park, Jin-Yi;Kim, Dasomi;Han, Sang-Sun;Yu, Hyung-Seog;Cha, Jung-Yul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.257-263
    • /
    • 2019
  • Purpose: This study was performed to evaluate the dimensional accuracy of digital dental models constructed from cone-beam computed tomographic (CBCT) scans of polyvinyl siloxane (PVS) impressions and cast scan models. Materials and Methods: A pair of PVS impressions was obtained from 20 subjects and scanned using CBCT (resolution, 0.1 mm). A cast scan model was constructed by scanning the gypsum model using a model scanner. After reconstruction of the digital models, the mesio-distal width of each tooth, inter-canine width, and inter-molar width were measured, and the Bolton ratios were calculated and compared. The 2 models were superimposed and the difference between the models was measured using 3-dimensional analysis. Results: The range of mean error between the cast scan model and the CBCT scan model was -0.15 mm to 0.13 mm in the mesio-distal width of the teeth and 0.03 mm to 0.42 mm in the width analysis. The differences in the Bolton ratios between the cast scan models and CBCT scan models were 0.87 (anterior ratio) and 0.72 (overall ratio), with no significant difference (P>0.05). The mean maxillary and mandibular difference when the cast scan model and the CBCT scan model were superimposed was 53 ㎛. Conclusion: There was no statistically significant difference in most of the measurements. The maximum tooth size difference was 0.15mm, and the average difference in model overlap was 53 ㎛. Digital models produced by scanning impressions at a high resolution using CBCT can be used in clinical practice.

Development of New Orthognathic Model Surgery Technique Based on the Reference Points onto the Teeth and the Use of Occlusal Index (치아 기준의 악교정 수술용 석고모형 수술, 과연 가능하고 정확한가)

  • Lee, Seung-Hoon;Oh, Seong-Seob;Yi, Choong-Kook;Park, Kyung-Ran;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.128-136
    • /
    • 2011
  • Purpose: Errors in orthognathic model surgery occur during the planning, measuring and/or moving of the models. However, there has been little effort to find ways to reduce these errors. In this study, we introduce a new orthognathic model surgery technique (Yonsei method) which adopts the tooth point as the reference and the occlusal index as a moving vehicle for the model. Methods: The technique consists mainly of: 1) measuring the three-dimensional lengths of model points, 2) fabricating and moving the occlusal index and 3) verifying the movement. Then we compared the accuracy of the Yonsei method to conventional methods, with special reference made to influencing factors. Results: Errors for the Yonsei method with the occlusal index were reduced to the range of 0.61~1.04 mm in three-dimension, providing a more accurate model surgery technique than conventional methods which have errors ranging from 0.77~3.11 mm. Conclusion: It provided us a more accurate model surgery technique based on the reference points onto the teeth and the use of occlusal index.

Dysesthesia after Tooth Extraction and Implant Surgery Reported by Dentists (치과의사에 의해 보고된 발치 및 임프란트 수술 후 지각이상에 대한 분석)

  • Ryu, Ji-Won;Kwon, Jeong-Seung
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.263-272
    • /
    • 2007
  • The purpose of this study was to analyze the nerve damage after tooth extraction and implant surgery, and to establish a predictive model for assessment and management of dysesthesia. In this questionnaire study, the subjects chosen for this study were 276 dentists who answered the questionnaire about dysesthesia after tooth extraction and implant surgery. The analysis of the results consist of the sex and age distribution, affected site, associated symptoms, rate and duration of the recovery. The results are summarized as follows. : 1. There were no significant difference between the sex and the dysesthesia. 2. The most common affected site was the mandibular region. In the group of the implant surgery, 100% affected the mandibular site. The tooth extraction group was 93.2% affected. 3. Pain was one of the most associated symptom with dysesthesia-46.5% of the tooth extraction and 44.8% of the implant surgery. 4. The recovery ratio was 72.3% in the tooth extraction, 71.8% in the implant surgery. Most of them, they recovered in $1{\sim}6$ months. In conclusion, most of dysesthesia may be recovered within 1 year. However, the possibility of persistent dysesthesia should not be neglected. Therefore, practitioners must discuss the possibility of nerve injury with their patients, and include this possibility in the consent forms. Various methods of monitoring recovery of sensation should be considered for objective assessment of prognosis. In addition, immediate referral to orofacial pain specialists can offer the patients an opportunity for more effective and noninvasive treatments.

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

Optimum Shape Design of Gearbox Housing for 5MW Wind Turbines (5MW급 풍력발전기용 기어박스 하우징의 형상 최적설계)

  • Jeong, Ki-Yong;Lee, Dae-Yeon;Choi, Eun-Ho;Cho, Jin-Rea;Lim, O-Kaung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.237-243
    • /
    • 2012
  • The thickness optimization of the gearbox housing for 5MW wind turbine is carried out with the help of the efficient structure analysis model and the approximation model of objective function. Wind turbine gearbox is a complex structural system composed of a number of gear trains, shafts, bearing and gearbox housing, requiring a tremendous number of elements for the structural analysis and design. In this paper, an effective analysis and design model considering the tooth stiffness of helical gears is proposed. It enables to significantly reduce the total element number and the analysis time. Through the numerical optimization of housing thickness making use of the effective gearbox model and the approximate model of objective function, the total weight of the gearbox housing is minimized. It has been observed from the numerical experiment that the approximation model is reliable and the optimization result is acceptable and verified analysis.

STRESS ANALYSIS OF ROOT AND SUPPORTING TISSUES BY VARIOUS POST CORE DESIGN (지대치 형태에 따른 Post core의 치근내부 및 지지조직의 응력분석)

  • Kim Jin;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.468-481
    • /
    • 1993
  • The Purpose of this study was to analyze the stresses and displacements of various post and core. The Finite element models of central incisors were divided into seven types according to the various amount of remaining tooth structures. $10kgf/mm^2$ force was applied respectively as follows : 1) Horizontal on the labial surface 2) $26^{\circ}$ diagonal direction on the lingual surface. Material property, geometry, and load condition of each model were inputted to the two dimensional ANSYS 4.4A finite element program : stresses and displacements were analyzed. Results were follows : 1. In the case of $130^{\circ}$ shoulder post and core, Maximum tensile and shear stresses were observed in the crown margin. 2. Maximum shear stress was about 29% reduced by contrabevel. 3. In the case of 1mm axial tooth structure, Maximum tensile stress observed in the dentin. 4. In the case of but joint of cervix, Maximum stress concentration was observed in the dentin by the inclined and horizontal force. 5. Horizontal force produced the extraordinary high stresses in dentin and supporting structures. 6. The amount of remaining tooth structure affected the level of stress significantly and it determined the location of stress concentration.

  • PDF

CPP-ACP of artificially demineralized enamel surface and remineralization of material containing nano-sized carbonated apatite (인공 탈회된 법랑질 표면의 CPP-ACP와 nano-sized carbonated apatite 함유물질의 재광화효과)

  • Kim, Young-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.13-22
    • /
    • 2008
  • This study compared tooth's remineralization using enamel surface artificially demineralized with 0.1M lactate and HCL solution using Vicker's Hardness Number(VHN) to compare CPP-ACP and remineralization of nano-sized Carbonate Apatite's initial caries. Using pH circulation models divided into 0% nano-CA, 5% nano-CA, 10% nano-CA, 10% CPP-ACP and D.W. they were treated for 5 minutes, three times a day for 14 days to get the following results. 1. There were no significant differences among the initial surface hardness of samples demineralized surface of front tooth in 5 groups. and all 5 groups' surface hardness reduced significantly after demineralization of enamel. 2. When inquiring into hardness changes through pH circulation model, the highest hardness change was in 5% nano-CA group. Also. 10% nano-CA and 10% CPP-ACP groups increased significantly. but there was no significant difference statistically. In generalizing the above experiment results, nano-sized Carbonate Apatite showed remineralization, and compared to 10% CPP-ACP group, 5% nano-CA had remineralization to artificial caries. thus implies that when we develop method to contact with tooth of nano-CA in the future, it is expected to gain synergy effect on function of saliva, a natural remineralization material.

  • PDF

The relationship of snack habits, oral health behavior and oral health status in psychiatric patients (일부 정신병원 입원환자의 구강건강상태와 구강건강행위 및 간식습관과의 관련성)

  • Lee, Eun-Gyeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.6
    • /
    • pp.1023-1030
    • /
    • 2013
  • Objectives : The purpose of the study is to investigate the relationship between variables associated with oral health status in psychiatric patients and to provide basic information on oral health education program development for the psychiatric patients. Methods : Subjects were 151 psychiatric patients who filled out the structured questionnaire. The data were analyzed for independent t-test, one-way ANOVA and hierarchical multiple regression by using SPSS Win Program 18.0 version. Results : Higher DMFT index was shown in the older age(p<0.001) and low perceived oral health group(p<0.001). Higher DMFT index included no tooth brushing after breakfast(p=0.045), wrong tooth brushing method(p<0.001). Chewing discomfort(p=0.027) and denture(p=0.027) were closely related to higher DMFT index. Bread(p=0.033) and snack(p<0.001) increased DMFT index. Factors affecting oral health status were age, denture, snack and bread. The explanation power of the final model was 29.4%. Conclusions : Dietary control for the psychiatric patients is very important to prevent dental caries. Tooth brushing and use of oral hygiene devices can improve good oral health care. Furthermore, this result can improve the oral health care for the disabled people.