Development of New Orthognathic Model Surgery Technique Based on the Reference Points onto the Teeth and the Use of Occlusal Index

치아 기준의 악교정 수술용 석고모형 수술, 과연 가능하고 정확한가

  • Lee, Seung-Hoon (Leader's Dental Clinic) ;
  • Oh, Seong-Seob (21st Century Dental Clinic) ;
  • Yi, Choong-Kook (Department of Oral and Maxillofacial Surgery, College of Dentistry, Yonsei University) ;
  • Park, Kyung-Ran (Department of Oral and Maxillofacial Surgery, College of Dentistry, Yonsei University) ;
  • Lee, Sang-Hwy (Department of Oral and Maxillofacial Surgery and Applied Life Science, Oral Science Research Center, Oral Cancer Research Institute, Brain Korea 21 Project, College of Dentistry, Yonsei University)
  • 이승훈 (리더스치과의원) ;
  • 오성섭 (21세기치과병원) ;
  • 이충국 (연세대학교 치과대학 구강악안면외과학교실) ;
  • 박경란 (연세대학교 치과대학 구강악안면외과학교실) ;
  • 이상휘 (연세대학교 치과대학 구강악안면외과학교실, 구강과학연구소, 구강종양연구소)
  • Received : 2010.12.27
  • Accepted : 2011.02.24
  • Published : 2011.03.31

Abstract

Purpose: Errors in orthognathic model surgery occur during the planning, measuring and/or moving of the models. However, there has been little effort to find ways to reduce these errors. In this study, we introduce a new orthognathic model surgery technique (Yonsei method) which adopts the tooth point as the reference and the occlusal index as a moving vehicle for the model. Methods: The technique consists mainly of: 1) measuring the three-dimensional lengths of model points, 2) fabricating and moving the occlusal index and 3) verifying the movement. Then we compared the accuracy of the Yonsei method to conventional methods, with special reference made to influencing factors. Results: Errors for the Yonsei method with the occlusal index were reduced to the range of 0.61~1.04 mm in three-dimension, providing a more accurate model surgery technique than conventional methods which have errors ranging from 0.77~3.11 mm. Conclusion: It provided us a more accurate model surgery technique based on the reference points onto the teeth and the use of occlusal index.

Keywords

References

  1. Epker BN, Fish LC. Definitive immediate presurgical planning. In: Epker BN, Fish LC, editors. Dentofacial deformities. St. Louis: CV Mosby co.; 1986. p. 128-46.
  2. Ellis E III. Accuracy of model surgery. J Oral Maxillofac Surg 1990;48:1161-7. https://doi.org/10.1016/0278-2391(90)90532-7
  3. Lee SH, Lee SH, Ju HH, Won DH. The accuracy of measurements measurements during model surgery for orthognathic planning. J Korean Oral Maxillofac Surg 2001;27:37-45.
  4. Ellis E III. Accuracy of face-bow transfer. J Oral Maxillofac Surg 1992;50:562-7. https://doi.org/10.1016/0278-2391(92)90434-2
  5. Nattestad A, Vedtoft P. Pitfalls in orthognathic model surgery. Int J Oral Maxillofac Surg 1994;23:11-5. https://doi.org/10.1016/S0901-5027(05)80318-2
  6. Kim BC, Lee CE, Park W, et al. Clinical experiences of digital model surgery and the rapid-prototyped wafer for maxillary orthognathic surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:278-85. https://doi.org/10.1016/j.tripleo.2010.04.038
  7. Erickson KM, Bell WH, Goldsmith DH. Analytical model surgery. In: Bell WH, editor. Modern practice in orthognathic and reconstructive surgery. Philadelphia: WB Saunders co.; 1992. p. 154-216.
  8. Pretta FM, Caruso WA. The use of acrylic spacers in orthognthic model surgery. J Oral Maxillofac Surg 1983;41: 473-5. https://doi.org/10.1016/0278-2391(83)90136-2
  9. Anwar M, Harris M. Model surgery for orthognathic planning. Br J Oral Maxillofac Surg 1990;28:393-7. https://doi.org/10.1016/0266-4356(90)90037-L
  10. Ellis E 3rd, Gallo WJ. A method to accurately predict the position of the maxillary incisor in two-jaw surgery. J Oral Maxillofac Surg 1984;42:402-4. https://doi.org/10.1016/S0278-2391(84)80015-4
  11. Stanchina R, Ellis E 3rd, Gallo WJ, Fonseca RJ. A comparison of two measures for repositioning the maxilla during orthognathic surgery. Int J Adult Orhto Orthognath Surg 1988;3:149-54.
  12. Dahlberg G. Stastical methods for medical and biological students. Newyork. Interscience publication, 1940, cited from Sandler PJ: Reproducibility of cephalometric measurements. Br J Orthod 1988;15:105-10. https://doi.org/10.1179/bjo.15.2.105
  13. Omura T, Glickman RS, Super S. Method to verify the accuracy of model surgery and prediction tracing. Int J Adult Orthod Orthognath Surg 1996;11:265-70.
  14. Nattestad A, Vedtofte P, Mosekilde E. The significance of an erroneous recording of the centre of mandibular rotation in orthognathic surgery. J Craniomax Fac Surg 1991;19:254-9. https://doi.org/10.1016/S1010-5182(05)80066-6
  15. Schwestka R, Engelke D, Zimmer B, Kubein-Meesenburg D. Positioning control of the upper incisors in orthognathic surgery. Pre-operative planning with the Model Positioning Device and intra-operative application of the Sandwich Splint. Eur J Orthod 1991;13:367-71. https://doi.org/10.1093/ejo/13.5.367
  16. Bell WH. Correction of the short-face syndrome-vertical maxillary deficiency: a preliminary report. J Oral Surg 1977; 35:110-20.
  17. Bell WH, Creekmore TD, Alexander RG. Surgical correction of the long face syndrome. Am J Orthod 1977;71:40-67.
  18. Buckley MJ, Tucker MR, Fredette SA. An alternative approach for staging simultaneous maxillary and mandibular osteotomies. Int J Adult Orthodon Orthognath Surg 1987;2: 75-8.
  19. Cottrell DA, Wolford LM. Altered orthognathic surgical sequencing and a modified approach to model surgery. J Oral Maxillofac 1994;52:1010-20; discussion 1020-1. https://doi.org/10.1016/0278-2391(94)90164-3
  20. Fuhrmann RA, Frohberg U, Diedrich PR. Treatment prediction with three-dimensional computer tomographic skull models. Am J Orthod Dentofac Orthop 1994;106:156-60. https://doi.org/10.1016/S0889-5406(94)70033-8